SCOPE OF ACCREDITATION



Comtest Laboratories Pty Ltd
COMTEST LABORATORIES PTY LTD
| Accreditation Number: 3148 | Site Number: 21666 |

Address Details:
Unit 1/570 City Road
SOUTH MELBOURNE, VIC 3205
AUSTRALIA
Website: www.comtest.com.au
Contact Details:
Mr Robert Norris
+61(03) 96455933


Availability:Services available to external clients



Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

 

ISO/IEC 17025 (2005)
Calibration

SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION/RANGE
DC and low frequency electrical metrology - Electrical measurement and test equipmentLCR metersCapacitance; Inductance; Direct measurement against a reference standard
CAPABILITY
with Calibration and Measurement Capability of -
Capacitance
1.7 % at 1 nF and at 1 kHz
0.7 % at 10 nF and at 1 kHz
0.6 % at 100 nF and at 1 kHz
0.3 % at 1 μF and at 1 kHz
0.6 % at 10 μF and at 1 kHz
0.6 % at 100 μF and at 100 Hz
Inductance
1.2% at 1 mH and at 1 kHz
1.3% at 1.9 mH and at 1 kHz
1.2% at 5 mH and at 1 kHz
1.2% at 10 mH and at 1 kHz
1.2% at 19 mH and at 1 kHz
1.2% at 50 mH and at 1 kHz
1.2% at 100 mH and at 1 kHz
1.2% at 190 mH and at 1 kHz
1.2% at 500 mH and at 1 kHz
1.2% at 1 H and at 1 kHz
1.2% at 10 H and at 100 Hz


Digital multimeters (DMM); Ohm meters; ResistanceDirect measurement against a reference standard 

CAPABILITY
with Calibration and Measurement Capability of -
101 μΩ/Ω at 1 Ω
106 μΩ/Ω at 1.9 Ω
29 μΩ/Ω at 10 Ω
50 μΩ/Ω at 19 Ω
18 μΩ/Ω at 100 Ω
21 μΩ/Ω at 190 Ω
14 μΩ/Ω at 1 kΩ
18 μΩ/Ω at 1.9 kΩ
12 μΩ/Ω at 10 kΩ
17 μΩ/Ω at 19 kΩ
14 μΩ/Ω at 100 kΩ
30 μΩ/Ω at 190 kΩ
20 μΩ/Ω at 1 MΩ
125 μΩ/Ω at 1.9 MΩ
46 μΩ/Ω at 10 MΩ
654 μΩ/Ω at 19 MΩ
193 μΩ/Ω at 100 MΩ

Digital multimeters (DMM); Voltmeters; AC voltage; DC voltage; Direct measurement against a reference standard
CAPABILITY
with Calibration and Measurement Capability of - 
D.C. voltmeters
1.4 μV from 10 μV to 50 mV
12 μV/V from 50 mV to 220 mV
10 μV/V from 220 mV to 2.2 V
8 μV/V from 2.2 V to 11 V
9 μV/V from 11 V to 22 V
9 μV/V from 22 V to 220 V
12 μV/V from 220 V to 1100 
A.C. voltmeters
6 μV from 220 μV to 2.2 mV and from 10 Hz to 20 Hz
5 μV from 220 μV to 2.2 mV and from 20 Hz to 50 kHz
9 μV from 220 μV to 2.2 mV and from 50 kHz to 100 kHz
15 μV from 220 μV to 2.2 mV and from 100 kHz to 300 kHz
29 μV from 300 μV to 2.2 mV and from 300 kHz to 500 kHz
32 μV from 380 μV to 2.2 mV and from 500 kHz to 1 MHz
0.08% from 2.2 mV to 22 mV and from 10 Hz to 20 Hz
0.05% from 2.2 mV to 22 mV and from 20 Hz to 40 Hz
0.04% from 2.2 mV to 22 mV and from 40 Hz to 20 kHz
0.06% from 2.2 mV to 22 mV and from 20 kHz to 50 kHz
0.12% from 2.2 mV to 22 mV and from 50 kHz to 100 kHz
0.17% from 2.2 mV to 22 mV and from 100 kHz to 300 kHz
0.30% from 2.2 mV to 22 mV and from 300 kHz to 500 kHz
0.47% from 2.2 mV to 22 mV and from 500 kHz to 1 MHz
0.06% from 22 mV to 220 mV and from 10 Hz to 20 Hz
0.03% from 22 mV to 220 mV and from 20 Hz to 40 Hz
0.01% from 22 mV to 220 mV and from 40 Hz to 20 kHz
0.04% from 22 mV to 220 mV and from 20 kHz to 50 kHz
0.10% from 22 mV to 220 mV and from 50 kHz to 100 kHz
0.13% from 22 mV to 220 mV and from 100 kHz to 300 kHz
0.19% from 22 mV to 220 mV and from 300 kHz to 500 kHz
0.38% from 22 mV to 220 mV and from 500 kHz to 1 MHz
0.05% from 220 mV to 2.2 V and from 10 Hz to 20 Hz
0.02% from 220 mV to 2.2 V and from 20 Hz to 40 Hz
0.01% from 220 mV to 2.2 V and from 40 Hz to 20 kHz
0.03% from 220 mV to 2.2 V and from 50 kHz to 100 kHz
0.05% from 220 mV to 2.2 V and from 100 kHz to 300 kHz
0.12% from 220 mV to 2.2 V and from 300 kHz to 500 kHz
0.26% from 220 mV to 2.2 V and from 500 kHz to 1 MHz
0.05% from 2.2 V to 22 V and from 10 Hz to 20 Hz
0.02% from 2.2 V to 22 V and from 20 Hz to 40 Hz
0.01% from 2.2 V to 22 V and from 40 Hz to 20 kHz
0.03% from 2.2V to 22 V and from 50 kHz to 100 kHz
0.05% from 2.2 V to 22 V and from 100 kHz to 300 kHz
0.12% from 2.2 V to 22 V and from 300 kHz to 500 kHz
0.26% from 2.2 V to 22 V and from 500 kHz to 1 MHz
0.06% from 22 V to 219.9999 V and from 10 Hz to 20 Hz
0.03% from 22 V to 219.9999 V and from 20 Hz to 40 Hz
0.02% from 22 V to 219.9999 V and from 40 Hz to 20 kHz
0.04% from 22 V to 219.9999 V and from 20 kHz to 50 kHz
0.06% from 22 V to 219.9999 V and from 50 kHz to 100 kHz
0.24% from 22 V to 100 V and from 100 kHz to 300 kHz
0.04% from 220 V to 1100 V and from 15 Hz to 50 Hz
0.01% from 220 V to 1100 V and from 50 Hz to 1 kHz
Ammeters; Digital multimeters (DMM); AC current; DC current; Direct measurement against a reference standard
CAPABILITY
with Calibration and Measurement Capability of -
D.C. ammeters
15 nA from 100 nA to 22 μA
95 μA/A from 22 μA to 220 μA
62 μA/A from 220 μA to 22 mA
105 μA/A from 22 mA to 220 mA
107 μA/A from 220 mA to 2.2 A
0.1% from 2.2 A to 20 A
A.C. ammeters
45 nA from 9 μA to 22 μA and from 10 Hz to 20 Hz
37 nA from 9 μA to 22 μA and from 20 Hz to 40 Hz
27 nA from 9 μA to 22 μA and from 40 Hz to 1 kHz
97 nA from 9 μA to 22 μA and from 1 kHz to 5 kHz
302 nA from 9 μA to 22 μA and from 5 kHz to 10 kHz
0.08 % up to 22 μA to 220 μA and from 10 Hz to 20 Hz
0.05 % up to 22 μA to 220 μA and from 20 Hz to 40 Hz
0.02 % up to 22 μA to 220 μA and from 40 Hz to 1 kHz
0.08 % up to 22 μA to 220 μA and from 1 kHz to 5 kHz
0.23 % up to 22 μA to 220 μA and from 5 kHz to 10 kHz
0.07 % from 220 μA to 220 mA and from 10 Hz to 20 Hz
0.04 % from 220 μA to 220 mA and from 20 Hz to 40 Hz
0.02 % from 220 μA to 220 mA and from 40 Hz to 1 kHz
0.08 % from 220 μA to 220 mA and from 1 kHz to 5 kHz
0.20 % from 220 μA to 220 mA and from 5 kHz to 10 kHz
0.07% from 220 mA to 2.2 A and from 20 Hz to 1 kHz
0.09% from 222 mA to 2.2 A and from 1 kHz to 5 kHz
0.87% from 220 mA to 2.2 A and from 5 kHz to 10 kHz
0.29% from 2.2A to 20 A and from 50 Hz to 500 Hz
Time and frequency metrology - Frequency, time and waveform measuring equipmentFrequency analysersFrequencyComparison with a reference standard
CAPABILITY
with Calibration and Measurement Capability of -
3.1 μHz/Hz at 0.1 Hz
8.0 μHz/Hz at 0.2 Hz
7.9 μHz/Hz at 0.5 Hz
9.2 μHz/Hz at 1 Hz
0.31 μHz/Hz at 2 Hz
0.17 μHz/Hz at 5 Hz
0.59 μHz/Hz at 10 Hz
0.31 μHz/Hz at 20 Hz
0.17 μHz/Hz at 50 Hz
0.59 μHz/Hz at 100 Hz
0.32 μHz/Hz at 200 Hz
0.18 μHz/Hz at 500 Hz
0.59 μHz/Hz at 1 kHz
0.32 μHz/Hz at 2 kHz
0.18 μHz/Hz at 5 kHz
0.59 μHz/Hz at 10 kHz
0.32 μHz/Hz at 20 kHz
0.18 μHz/Hz at 50 kHz
0.59 μHz/Hz at 100 kHz
0.32 μHz/Hz at 200 kHz
0.18 μHz/Hz at 500 kHz
0.59 μHz/Hz at 1 MHz
0.32 μHz/Hz at 2 MHz
0.16 μHz/Hz at 5 MHz
0.13 μHz/Hz at 10 MHz
23 μHz/Hz at 20 MHz
23 μHz/Hz at 50 MHz
23 μHz/Hz at 100 MHz

| Accreditation Number: 3148 | Site Number: 21666 | Printed on : 21-Jul-2019

 

--------------------- END OF SCOPE ----------------------