Scope of Accreditation

Melbourne Laboratory – EMC Test Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
High frequency electrical metrology - Communications, electromagnetic field strength and EMC test equipment Active rod antennas; Biconical antennas; Horn antennas; Log periodic antennas Antenna factor; Frequency Direct measurement by electrical input SAE ARP 958, version D

Capability

Narrowband transducers and indicators
Radiofrequency antenna

with Calibration and Measurement Capability of-

Antenna Factor from -5 dB(1/m) up to 50 dB(1/m)

± 1.0 dB from 9kHz to 40 GHz
Active Rod antennas 9kHz to 30MHz
Biconical antennas 30MHz to 300MHz
Log periodic antennas 200MHz to 1000MHz
Large Horn antennas 200MHz to 2000MHz
Small Horn antennas 1GHz to 40 GHz 

Artificial mains networks (AMN); Line impedance stabilisation networks (LISN) Voltage division factor Direct measurement by electrical input

Capability

with Calibration and Measurement Capability of -

in the frequency range 9 kHz to 108 MHz

± 0.6 dB for voltage division factor  

± 2.1% for voltage drop

± 10.9% for impedance
± 3.8º for phase
Coupling/decoupling networks (CDN) Insertion loss Direct measurement by electrical input

Capability

with Calibration and Measurement Capability of -

in the frequency range 150 kHz to 230 MHz

± 10.9% for impedance

E&H field probes and meters; Electromagnetic field hazard meters and warning indicators Frequency Comparison with a reference standard

Capability

with Calibration and Measurement Capability of-

Calibration of E & H-field probes in the range 
0.01 MHz to 433 MHz at 120 V/m and 2.4 A/m
433 MHz to 1 GHz at 61.4 V/m and 0.55 A/m
1 GHz to 3 GHz at 61.4 V/m

3 GHz to 8 GHz at 61.4 V/m

8 GHz to 18 GHz at 61.4 V/m

± 1.2 dB from 0.01 MHz to 3 GHz

± 1.5 dB from 3 GHz to 8 GHz

± 1.8 dB from 8 GHz to 18 GHz



Electrical fast transients (EFT) and surge generators Pulse characteristics Direct measurement by electrical input

Capability

Electrical fast transients (EFT)

with Calibration and Measurement Capability of -

in the range ± 0.5 kV to 20 kV

± 5.80% for peak voltage

± 4.2% for pulse width
± 1.2% for rise time
± 3.07% for repetition rate
Pulse characteristics Direct measurement by electrical input

Capability

Surge Generators

with Calibration and Measurement Capability of -

in the range ± 0.1 kV to 7 kV

± 5.60% for open circuit voltage

± 10.53% for open circuit front time
± 4.4% for open circuit duration
± 4.4% for short circuit current
± 4.29% for short circuit front time
± 4.3% for short circuit duration
Electrostatic discharge (ESD) generators Pulse characteristics Direct measurement by electrical input

Capability

with Calibration and Measurement Capability of -

in the range ± 2 kV to ± 30 kV

± 14.2% for rise time

± 8.10% for peak current
± 1.2% for peak voltage
Harmonic emission compliance test systems Harmonic currents Comparison with a reference standard by differential measurement

Capability

with Calibration and Measurement Capability of -

0.15% of the fundamental of current for Harmonic currents 

- from 0.7 A to 16 A total rms per phase 

- from 1st to 40th harmonic with fundamental frequency between 50 to 60 Hz and voltage between 120 to 230 V

Line impedance stabilisation networks (LISN) Voltage division factor Direct measurement by electrical input

Capability

Balanced Telecom ISN (TLISN)

with Calibration and Measurement Capability of -

in the frequency range 150 kHz to 30 MHz

± 4.3 Ω for common mode impedance  

± 2.4º for common mode phase
± 0.97 dB for voltage division factor

± 1.12 dB for isolation / DCMD

± 2.28 dB for Longitudinal conversion loss (LCL)
Voltage fluctuation and flicker compliance test systems Internal reference impedance resistance; Short term flicker; Voltage deviation Comparison with a reference standard by substitution measurement

Capability

with Calibration and Measurement Capability of -

0.5% of Pst in the range from 0.5 Ps to 1.5 Ps for Short term flicker perceptibility

0.07% of fundamental of the voltage in the range from 0.5 to 2.0% for Voltage deviation, Dmax, with fundamental frequency between 50 Hz to 60 Hz and voltage between 1 V to 230 V

1.8 MΩ for Internal reference impedance resistance