PRINT SCOPE


National Association of Testing Authorities, Australia

SCOPE OF ACCREDITATION



EMC Bayswater Pty Ltd
EMC BAYSWATER PTY LTD
| Accreditation Number: 18553 | Site Number: 20485 |

Date of Accreditation: 09/05/2011

Address Details:
Unit 18, 88 Merrindale Drive
CROYDON SOUTH, VIC 3136
AUSTRALIA
Website: www.emcbayswater.com.au
Contact Details:
Mr Neville Liyanapatabendige
+61(03) 97615888


Availability:Services available to external clients



Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

 

ISO/IEC 17025 (2017)
Manufactured Goods

SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION/RANGE
Assessment of emissions and immunity - EMC emission standardsVehicles, boats and internal combustion engine driven equipmentConducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS CISPR 12 ; 
CISPR 12 ; 
EN 55012 ;
EN 55025
excluding insertion loss of ignition noise suppressors
Industrial, scientific and medical (ISM) radio-frequency equipmentConducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZSCISPR 11 ; 
CISPR 11 ; 
EN 55011 ;
ICES-001 ;
CAN/CSA-CEI/IEC CISPR 11
excluding measurements below 9 kHz
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS CISPR 25 and CISPR 25
Residential, commercial and light industrial environmentsConducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableAS/NZS 61000.6.3 ;
EN 61000-6-3 ; 
IEC 61000-6-3 ;
BS EN 50491-5-2 ;

Medical electrical equipmentConducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableIEC 60601-1-2 ; 
EN 60601-1-2

Aerospace and military grade equipmentConducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableMIL-STD-461D, E and F methods CE101, CE102, RE101 and RE102
Electrical equipment for measurement, control and laboratory useConducted emissions; Conducted interference; Not applicableAS/NZS CISPR 11;CISPR 11; EN 55011excluding measurements below 9 kHz
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableIEC 61326-1; EN 61326-1
Information technology equipmentConducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS CISPR 22 ;
CISPR 22 ; 
EN 55022 ;
ICES-003 ;
CAN/CSA-CEI/IEC CISPR 22

Information technology equipment; Multimedia equipment; Conducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS CISPR 32, CISPR 32 and EN 55032
Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygenConducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableEN 50270
Electrical lighting and similar equipmentConducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS CISPR 15, CISPR 15 and EN 55015
Sound and television broadcast receivers and associated equipmentConducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS CISPR 13, CISPR 13 and EN 55013
Railway electronic equipment used on rolling stock; Rolling stock - Train and complete vehicle; Conducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableEN 50121-3-2
EN 50155 clause 5.4 and 5.5 [referencing clause 12.2.7 and 12.2.8]

Audio, video, audio-visual and entertainment lighting control apparatus for professional useConducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableEN 55103-1Excluding testing of harmonics and flicker with products >16 Amps mains supply
Road traffic signal systems and devicesConducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableEN 50293
EN 50556 clause 6.7

Electrical and electronic productsMains harmonics and flickerNot applicableAS/NZS 61000.3.2 ;
EN 61000-3-2 ;
AS/NZS 61000.3.3 ; 
EN 61000-3-3

Electrical and electronic products; Information technology equipment; Conducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableANSI C63.4: 2014 for unintentional emitters ;
ANSI C63.10: 2013 for intentional radiators ; 
Unintentional Radiators described in FCC Part 15, Subpart B using ANSI C63.4-2014 ; 
Intentional radiators described in FCC part 15, Subpart C using ANSI C63.4-2014 and ANSI C63.10-2013 ;
KDB Guidelines : KDB 789033 D02, KDB 558074 D01, and KDB 905462 ; 
ICES-003 ; 
RSS-210 ;
RSS-247 ; 
RSS-GEN
Frequency range of 9 kHz to 40 GHz



Radiated Measurements conducted at 3 metre iOATS Semi Anechoic Chamber Croydon South
Electrical and electronic products; Power tools - Electric; Conducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS CISPR 14-1, CISPR 14-1 and EN 55014-1
Machine toolsConducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS CISPR 11, CISPR 11, EN 55011 
excluding measurements below 9 kHz
Railway vehicles and equipment including railway signalling and telecommunications equipmentConducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableEN 50121-4
In-vitro diagnostic (IVD) medical equipmentConducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableIEC 61326-2-6; EN 61326-2-6
Industrial environmentsConducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableAS/NZS 4251.1 ;
AS/NZS 4251.2 ; 
AS/NZS 61000.6.4 ; 
EN 61000-6-4 ;
IEC 61000-6-4

Radio equipmentConducted and radiated emissions; Conducted emissions; Radiated emissions; Radiated interference; Not applicableETSI EN 300 328 
all tests applicable to transmitters with output power of less than and including 10 dBm EIRP
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS 4268in the frequency range 9 kHz to 26.5 GHz
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference; Not applicableETSI EN 301 489-1

Conducted emissions; Conducted interference; Radiated emissions; Radiated interference; Not applicableAS/NZS 4268
Shielded enclosuresAttenuation performanceNot applicableMIL-STD-285
IEEE Std 299

Assessment of emissions and immunity - EMC immunity standardsGaming machinesConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableAS/NZS GMNS clauses 2.3.52 to 2.3.59
Residential, commercial and light industrial environmentsConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 61000-6-1 ;
AS/NZS 61000.6.1 ;
IEC 61000-6-1 ;
EN 50491-5-2

Medical electrical equipmentConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableIEC 60601-1-2, EN 60601-1-2
Aerospace and military grade equipmentConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableMIL-STD-461 D, E and F methods CS 101, CS 106, CS 109, CS 114, RS 101 and RS 103
Electrical equipment for measurement, control and laboratory useConducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 50270
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 61326-1; IEC 61326-1
Information technology equipmentConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableAS/NZS CISPR 24; CISPR 24; EN 55024
Information technology equipment; Multimedia equipment; Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableCISPR 35; EN 55035Excluding Broadband impulsive conducted disturbances test

Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygenConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 50270
Electrical relays; Measuring relays and protection equipment; Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableIEC 60225-22-6
Electrical lighting and similar equipmentConducted disturbance; Electrical fast transient; Electrostatic discharge; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 61547
Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity; Not applicableEN 55103-2
Railway electronic equipment used on rolling stockConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 50155 Clause 5.4 and 5.5 [referencing clause 12.2.7 and 12.2.8]
Railway electronic equipment used on rolling stock; Rolling stock - Train and complete vehicle; Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 50121-3-2
Audio, video, audio-visual and entertainment lighting control apparatus for professional useConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 55103-2
Road traffic signal systems and devicesConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Surge immunity; Voltage short dips and interruptions; Voltage spikes; Not applicableEN 50293
EN 50556 clause 6.7

Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity; Not applicableEN 50293
EN 50556 clause 6.7

Electrical and electronic productsPulsed magnetic fieldNot applicableEN 61000-4-9 ;
IEC 61000-4-9 ;
AS/NZS 61000.4.9 ;

Radiated radio-frequencyNot applicableIEC 61000-4-3 ;
EN 61000-4-3 ; 
AS/NZS 61000.4.3 

Electrical fast transientNot applicableEN 61000-4-4 ;
IEC 61000-4-4 ;
AS/NZS 61000.4.4 ;
IEC 60335-1 Section 19.11.4.3

Power frequency magnetic fieldNot applicableEN 61000-4-8 ;
IEC 61000-4-8 ; 
AS/NZS 61000.4.8 

Electrostatic dischargeNot applicableEN 61000-4-2 ;
IEC 61000-4-2 ;
AS/NZS 61000.4.2 ;
IEC 60335-1 Section 19.11.4.1

Conducted disturbance; Induced signal susceptibility; Not applicableEN 61000-4-6 ;
IEC 61000-4-6 ;
AS/NZS 61000.4.6 ;
IEC 60335-1 Section 19.11.4.5

Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 61000-4-11 ;
IEC 61000-4-11 ;
AS/NZS 61000.4.11 ;
IEC 60335-1 Section 19.11.4.6
For appliances having a rated current not exceeding 16 A
Surge immunityNot applicableEN 61000-4-5 ;
IEC 61000-4-5 ;
AS/NZS 61000.4.5 ;
IEC 60335-1 Section 19.11.4.4

Electrical and electronic products; Information technology equipment; Radio equipment; Telecommunication network equipment; Radiated radio-frequencyNot applicableIEC 61000-4-3; 
EN 61000-4-3 ;
AS/NZS 61000.4.3 ;
IEC 60335-1 Section 19.11.4.2

Electrical and electronic products; Power tools - Electric; Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 55014-2; AS/NZS CISPR 14-2, CISPR 14-2
Machine toolsConducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity; Not applicableEN 50370-2
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 50370-2
Railway vehicles and equipment including railway signalling and telecommunications equipmentConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 50121-4
Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Radiated susceptibility; Not applicableEN 50121-3-2
EN 50121-4
EN 50155 clause 5.4 and 5.5 [referencing clause 12.2.7 & 12.2.8]

In-vitro diagnostic (IVD) medical equipmentConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 61326-2-6; EN 61326-2-6
Industrial environmentsConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 61000-6-2, AS/NZS 61000.6.2, IEC 61000-6-2
Radio equipmentConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableETSI EN 301 489-1
Components of fire, intruder and social alarm systemsConducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Not applicableEN 50130-4
Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity; Not applicableEN 50130-4 [excluding testing using EN 61000-4-20 methodology]Excluding testing using EN 61000-4-20 methodology
Assessment of emissions and immunity - Non-ionising radiation strength and hazard assessmentAntennas; Broadcast and telecommunication equipment installations; Hand held and wireless communication devices; Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields; Radiated field strength measurements; Not applicableCanadian Standard RSS-102 (RF Exposure Evaluation and Nerve Stimulation - for external fields only, excluding SAR measurements)
| Accreditation Number: 18553 | Site Number: 20485 | Printed on : 27-Feb-2021

 