PRINT SCOPE


National Association of Testing Authorities, Australia

SCOPE OF ACCREDITATION



CSIRO
FIRE SYSTEMS LABORATORY
| Accreditation Number: 165 | Site Number: 549 |

Address Details:
Gate 5, 2 Normanby Road
CLAYTON, VIC 3168
AUSTRALIA
Website: www.csiro.au
Contact Details:
Mr Peter Haggar
+61(03) 95452494


Availability:Services available to external clients



Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

 

ISO/IEC 17025 (2005)
Manufactured Goods

SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION/RANGE
Electrical equipment approval and safety evaluationFire detection and warning devicesEffect of environmental exposure on electrical equipment and enclosuresVibrationAS 60068.2.6; IEC 60068-2-6 (Sinusoidal vibration only)



Sinusoidal vibration
Fire detection and protection systems including control and indicating equipmentElectrical safetyEndurance and resistance to external conditions; Function assessment including abnormal operation; for the purpose of environmental design and construction compliance
AS 2220.1 (except clause 5.3.2.7);
AS 4428 Series
AS 4428.0 (excluding clauses 4.3.7 and 4.3.8), AS 4428.1, AS 4428.3, AS 4428.4, AS 4428.5, AS 4428.6, AS 4428.7, AS 4428.9; 
AS 7240 Series 
AS 7240.2 (excluding clause 16.8), AS 7240.4 (excluding clause 9.9)


Fire detection, emergency alarm, warning, control and intercommunication systems


Fire detection and protection systems including control and indicating equipment; Fire detection and warning devices; Effect of environmental exposure on electrical equipment and enclosuresShock (impact); Vibration; AS 60068.2.47



Mounting of components, equipment an other articles for vibration, impact and similar dynamic tests
Effect of environmental exposure on electrical equipment and enclosuresDry heatAS60068.2.2; IEC 60068-2-2
Effect of environmental exposure on electrical equipment and enclosuresColdAS 60068.2.1, IEC 60068-2-1
Effect of environmental exposure on electrical equipment and enclosuresHammerAS 60068.2.75; IEC 60068-2-75 
Effect of environmental exposure on electrical equipment and enclosuresDamp heat - Cyclic (12 + 12 hour cycle)AS 60068.2.30; IEC 60068-2-30
Effect of environmental exposure on electrical equipment and enclosuresDamp heat - Steady stateAS 60068.2.78; IEC 60068-2-78
Evaluation of electrical appliances and devices - PerformanceCells and batteriesCapacity; Charge retention; Not applicableAS/NZS 4029.2;
IEC 60896-2:MOD clauses 5.1 and 5.4 only;
ActivFire Specification TS001 


Sealed batteries used in control and indicating equipment


Evaluation of fire risk (excluding electrical products) and fire mitigation performanceFire detection and warning devicesFunctional and compatibility assessmentNot applicablefor the purpose of environmental design and construction compliance
AS 7240.7 (excluding clauses 5.7, 5.12, 5.13, 5.17 and 5.18


Smoke detectors


Fire detection and warning devicesFunctional and compatibility assessmentNot applicablefor the purpose of environmental design and construction compliance
AS 7240.5 (excluding clauses 5.13, 5.14 and 5.18


Heat detectors


Fire detection and warning devicesHeat sensitivityNot applicableAS 2362.1

Actuating devices for automatic fire detection and alarm systems Types A, B, C and D heat detectors


Fire detection and warning devicesEnduranceNot applicableAS 2362.21

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesSound pressure levelNot applicableAS 2362.22

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesDamp heatNot applicableFTS 119 SSL Test specification

Sample testing of smoke detectors


Fire detection and warning devicesCarbon monoxide sensitivityNot applicableAS 2362.26

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesLow temperatureNot applicableAS 2362.10

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesFrangibilityNot applicableAS 2362.14

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesVoltage stabilityNot applicableAS 2362.4

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesFunctional and compatibility assessmentNot applicablefor the purpose of environmental design and construction compliance
AS 3786 (excluding clause 5.15.1 and 5.25)


Smoke alarms


Fire detection and warning devicesSensitivityNot applicableAS 2362.17

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesStatic dischargeNot applicableAS 2362.6

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesIndicator visibilityNot applicableAS 2362.25

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesDamp heatNot applicableAS 2362.11

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesFunctional and compatibility assessmentNot applicableAS 1603 series. 
AS 1603.1 , except clause 5.3.4
AS 1603.2 , except clause 5.3.4
AS 1603.3 , except clause 5.3.4
AS 1603.5 , except clause 3.5
AS 1603.7 , except clause 5.3.4
AS 1603.8 , except clause 4.3.5
AS 1603.11 , except clause 5.3.4
AS 1603.13 , except clause 5.3.4
AS 1603.14 , except clause 5.3.4

Tests as per AS 2362 series


Automatic fire detection and alarm systems Heat detectors, heat alarms, smoke detectors, warning devices and other related products


Fire detection and warning devicesDustNot applicableAS 2362.19

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesSensitivitySmoke detector test tunnelFTS 118 SSL Test specification

Smoke detectors


Fire detection and warning devicesImpactNot applicableAS 2362.16

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesRapid temperature rise effectsNot applicableAS 2362.3

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesVibrationNot applicableAS 2362.15

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesResistance to crushingNot applicableAS 2362.14

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesDry heatNot applicableAS 2362.12

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesOverloadNot applicableAS 2362.20

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesCorrosionNot applicableAS 2362.13

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesAir movement and stabilityNot applicableAS 2362.18

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesHeat sensitivityNot applicableAS 2362.2

Actuating devices for automatic fire detection and alarm systems Type E heat detectors


Fire detection and warning devicesCross sensitivityNot applicableAS 2362.27

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesImpulse voltage withstandNot applicableAS 2362.8

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesInsulation resistanceNot applicableAS 2362.5

Actuating devices for automatic fire detection and alarm systems


Fire detection and warning devicesHigh frequency disturbanceNot applicableAS 2362.9

Actuating devices for automatic fire detection and alarm systems


Fire sprinkler headsFunctional and compatibility assessment; Leakage; Not applicableSSL specification FTS 123 
AS 1851 clauses 3.21 a, b, c and clause 3.22 of Table 2.4.1.3 - (Testing only)

Thermal performance evaluation of building and insulating productsRigid and flexible thermal insulation materialsThermal conductivity; Thermal insulation performance; Thermal resistance measurement; Heat flow meter apparatusAS/NZS 4859.1; 
ASTM C518; 
ASTM C653 including AS/NZS 4859.1 - Appendix D;
ASTM C687 clauses 7.1 and 7.2
 
in the range of 0.1 m2 K/W to 10.0 mK/W
at sample thicknesses of 2 mm to 200 mm


Formed shapes and formed insitu materials; Blanket type mineral fibre insulation; Loose fill building insulation
Steady state thermal transmission properties

| Accreditation Number: 165 | Site Number: 549 | Printed on : 16-Sep-2019

 

--------------------- END OF SCOPE ----------------------