PRINT SCOPE


National Association of Testing Authorities, Australia

SCOPE OF ACCREDITATION



CI Scientific Pty Ltd
CI SCIENTIFIC PTY LTD
| Accreditation Number: 411 | Site Number: 404 |

Date of Accreditation: 08/03/1963

Address Details:
Unit 1, 9 Bearing Road
SEVEN HILLS , NSW 2147
AUSTRALIA
Website: www.ciscientific.com
Contact Details:
Mr Jurgen Cyrulla
+61(02) 98384488


Availability:Services available to external clients



Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

 

ISO/IEC 17025 (2017)
Calibration

SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION/RANGE
Dimensional metrology - Engineering equipment and precision instrumentsCentrifugesRotational speedComparison with a reference standard by differential measurementIn-house method CY 20821
CAPABILITY
With Calibration and measurement capability of -
0.05% of full scale or 3 rpm (whichever is greater)  from 500 rpm to 99,900 rpm
Mass - Determination of mass and calibration of weighing devicesMass standardsMassGravimetric measurement against reference mass
CAPABILITY
With Calibration and measurement capability of-
2 in 10⁶ or 20 μg (whichever is greater) in the range 1 mg to 30 kg
Mass - Determination of mass and calibration of weighing devicesLaboratory weighing devices; Precision laboratory balances; MassGravimetric measurement against reference mass
including on site calibrations



CAPABILITY
Including on site calibrations
With Calibration and measurement capability of-
2 in 10⁶ or 20 μg (whichever is greater) up to 30 kg
Mass - Determination of mass and calibration of weighing devicesIndustrial weighing devicesMassGravimetric measurement against reference mass
including on site calibrations



CAPABILITY
Including on site calibrations
With Calibration and measurement capability of-
1 in 10μ or 1 mg (whichever is greater) up to 30 kg
Temperature metrology - Ancillary temperature measuring equipmentMulti-channel thermocouple data recorders; Process calibrators; Volt to temperature conversionDirect measurement by electrical input
CAPABILITY
With Calibration and measurement capability of-
0.2 °C from -100 °C to 500 °C
0.3 °C from 500 °C to 1100 °C
Temperature metrology - Temperature measuring equipmentDigital temperature measuring systemsTemperatureMeasurement against reference standard
CAPABILITY
With Calibration and measurement capability of-
0.4 °C from -80 °C to 250 °C
0.6 °C from 250 °C to 500 °C
2.5 °C from 500 °C to 1100 °C
Temperature metrology - Verification of controlled enclosuresAutoclaves and sterilising ovens; Baths; Freezers; Furnaces; Incubators; Ovens; Gradient; Spatial uniformity; Direct temperature measurementAS 2853
CAPABILITY
With Calibration and measurement capability of -
0.9 °C in the range from 0 °C to 250 °C for Ovens and Furnaces
2.6 °C in the range from 250 °C to 1100 °C for Ovens and Furnaces
0.9 °C in the range from -40 °C to 100 °C for Incubators
0.8 °C in the range from 100 °C to 130 °C for Autoclaves and sterilising ovens
1 °C in the range from 131 °C to 160 °C for Autoclaves and sterilising ovens
1 °C in the range from -80 °C to -16 °C for Industrial freezers
0.9 °C in the range from -15 °C to ambient for Industrial freezers
0.8 °C in the range from 0 °C to 130 °C for Baths
Torque - Torque measuring and testing equipmentTorque wrenchesTorqueComparison with a reference standardISO 6789.2 and in house method 5.23
CAPABILITY
With Calibration and Measurement Capability of -
1.2% from 1.25 Nm to 1500 Nm
Volume and density - Determination of densityAlcohol meters; Apparent density (draft survey) hydrometers; Bark hydrometer; Baume hydrometer; Brix hydrometers; Density hydrometers; Soil (colloidal solution) hydrometers; Specific gravity hydrometers; Baume; Brix; g/L; Percentage (%) alcohol by volume; Specific gravity; Gravimetric method
CAPABILITY
With Calibration and measurement capability of -
1/3 of the smallest scale division in the range 0 to 2.0 g/ml for Density Hydrometers;
1/3 of the smallest scale division in the range 0.990 to 1.040 kg/L for Apparent Density Hydrometers;
1/3 of the smallest scale division in the range -5 to +60 g/l for Soil Hydrometers;
1/3 of the smallest scale division in the range 0 to 90° Bx for Brix Hydrometers;
1/3 of the smallest scale division in the range 0 to 80° Bk for Bark Hydrometers;
1/3 of the smallest scale division in the range 0 to 90° Be for Baume Hydrometers;
1/3 of the smallest scale division in the range 0.6 to 2.0 for Specific Gravity Hydrometers;
1/3 of the smallest scale division in the range 0 to 100% for Alcohol Hydrometers
| Accreditation Number: 411 | Site Number: 404 | Printed on : 25-Feb-2021

 

--------------------- END OF SCOPE ----------------------