PRINT SCOPE


National Association of Testing Authorities, Australia

SCOPE OF ACCREDITATION



Australian Pressure Laboratory Pty Ltd
AUSTRALIAN PRESSURE LABORATORY PTY LTD
| Accreditation Number: 9727 | Site Number: 9720 |

Address Details:
Unit 9, 39 Susan Street
ELTHAM, VIC 3095
AUSTRALIA
Website: www.auspressurelab.com.au
Contact Details:
Mr Randall Anderson
+61(03) 94313658


Availability:Services available to external clients



Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

 

ISO/IEC 17025 (2005) - The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Calibration

SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION/RANGE
DC and low frequency electrical metrology - Electrical instrument calibratorsInstrument calibratorsDC current; DC voltage; Direct measurement against a reference standardD.C. voltage
From 0 V to 100 V
D.C. current
From 0 mA to 100 mA

CAPABILITY
with Calibration and Measurement Capability of -
D.C. voltage 
0.004% of reading or 0.004 mV (which ever is the greater)
D.C.current
0.0075% of reading or 0.0006 mA (which ever is the greater)
DC and low frequency electrical metrology - Electrical measurement and test equipmentAmmeters; Digital multimeters (DMM); Voltmeters; DC current; DC voltage; Direct measurement against a reference standardD.C. ammeters
From 0 mA to 100 mA
D.C. voltmeters
From 0 V to 100 V


CAPABILITY
with Calibration and Measurement Capability of -
D.C. ammeters
0.0075% of reading or 0.0006 mA ( whichever is the greater) 
D.C. voltmeters
0.004 % of reading or 0.004 mV ( whichever is the greater)
 
 
Mass - Determination of mass and calibration of weighing devicesPressure calibration standardsMassDirect measurement; Gravimetric measurement against reference mass; Dead weight testers up to 12 kg
CAPABILITY
With a Calibration and Measurement Capability of:
6 in 106 or 60μg (whichever is greater)
Pressure metrology - Pressure and vacuum measuring equipmentAir data test sets; Altimeters; Air speed; Feet altitude; Comparison with dead weight tester; Comparison with reference instrument; Equivalent feet altitude range of up to 80478 feet
Equivalent Air Speed range of 0 knots to 1195 knots



CAPABILITY
Including the calibration of Air Data Test Sets (ADTS) pitot and static ranges to the methods of MSA Test Method 1 - 2008 and based on pressure to altitude conversion as per ISO 2533:1997 from 2.7 kPa to 375 kPa absolute.
with Calibration and Measurement Capability of -
Altitude
0.003% reading or 5 Pa (whichever is the greater) from 2.7 kPa to 375 kPa absolute
equivalent uncertainty of measurement in feet altitude as per the pressure capability as converted.
Airspeed
Including the calibration of Air Data Test Sets (ADTS) airspeed ranges to the methods of MSA Test Method - 2008 and based on and pressure to airspeed as per NASA Technical Note D-822 
with Calibration and Measurement Capability of -
0.004% of reading or 0.5 Pa (whichever is the greater) from 0 kPa to 375 kPa
equivalent uncertainty of measurement in air speed as per the pressure capability as converted 
 
BarometersAbsolute pressureComparison with dead weight tester; Comparison with reference instrument; Absolute pressure calibration up to 120 MPa
Gauge barometers
Non mercurial barometers


CAPABILITY
with Calibration and Measurement Capability of -
0.003% of reading or 5 Pa (whichever is the greater) from 0.5 kPa to 2500 kPa
0.006%of reading from 2.5 MPa to 120 MPa

Digital pressure gauges; Manometers; Mechanical pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges; Absolute pressure; Gauge pressure; Comparison with dead weight tester; Comparison with reference instrument; Pressure gauges,  vacuum gauges ( bourdon type)
By the methods of -
AS 1349 and MSA Test Method 2 -2008
Pressure transducers
By the methods of  -
MSA Test Method 1 -2008
Pressure recorders
By the methods of  -
MSA Test Method 1 -2008
Gauge pressure calibration in the range -100 kPa to 280 MPa Including test gauges
Absolute pressure calibration up to 120 MPa including test gauges
Pressure transducers
Self indicating and electrical transducer  with a d.c. voltage or a d.c. current  output

CAPABILITY
with Calibration and Measurement Capability of
Gauge pressure calibration
0.004% of reading or 0.5 Pa (whichever is the greater) from -100 kPa to -5 kPa
0.3 Pa from -5 kPa to -0.0015 kPa
0.3 Pa from 0.0015 kPa to 5 kPa
0.004% of reading or 0.5 Pa (whichever is the greater) from 5 kPa to 20 kPa
0.003% of reading from 20 kPa to 2500 kPa
0.005% of reading from 2.5 MPa to 80 MPa
0.006% of reading from 80 MPa to 140 MPa
0.009% of reading from 140 MPa to 175 MPa
0.015% of reading from 175 MPa to 280 MPa
Absolute pressure calibration
0.003% of reading or 5 Pa (whichever is the greater) from 0.5 kPa to 2500 kPa
0.006% of reading from 2.5 MPa to 120 MPa



Pressure metrology - Pressure standardsPressure calibrators - Non-dead weightAbsolute pressure; Gauge pressure; Comparison with dead weight tester; Comparison with reference instrument; By the methods of  -
MSA Test Method 1 -2008
Gauge pressure calibration in the range -100 kPa to 280 MPa Including test gauges
Absolute pressure calibration up to 120 MPa including test gauges
Pressure transducers
Self indicating and electrical transducer  with a d.c. voltage or a d.c. current  output

CAPABILITY
with Calibration and Measurement Capability of
Gauge pressure calibration
0.004% of reading or 0.5 Pa (whichever is the greater) from -100 kPa to -5 kPa
0.3 Pa from -5 kPa to -0.0015 kPa
0.3 Pa from 0.0015 kPa to 5 kPa
0.004% of reading or 0.5 Pa (whichever is the greater) from 5 kPa to 20 kPa
0.003% of reading from 20 kPa to 2500 kPa
0.005% of reading from 2.5 MPa to 80 MPa
0.006% of reading from 80 MPa to 140 MPa
0.009% of reading from 140 MPa to 175 MPa
0.015% of reading from 175 MPa to 280 MPa
Absolute pressure calibration
0.003% of reading or 5 Pa (whichever is the greater) from 0.5 kPa to 2500 kPa
0.006% of reading from 2.5 MPa to 120 MPa



Air operated piston gauges; Dead weight testers - Ball and float type; Dead weight testers - Piston type; Oil operated piston gauges; Pressure calibrators - Non-dead weight; Gauge pressureComparison with dead weight tester; Comparison with reference instrument; Gauge pressure calibration
From -100 kPa to 280 MPa
Air operated piston gauges 
Calibration up to 8 MPa
 
Oil operated piston gauges 
Calibration up to 280 MPa

CAPABILITY
with Calibration and Measurement Capability of -
0.004% of reading or 0.5 Pa (whichever is the greater) from -100 kPa to -5 kPa
0.3 Pa from -5 kPa to -0.0015 kPa
0.3 Pa from 0.0015 kPa to 5 kPa
0.004% of reading or 0.5 Pa (whichever is the greater) from 5 kPa to 20 kPa
0.003% of reading from 20 kPa to 2500 kPa
0.005% of reading from 2.5 MPa to 80 MPa
0.006% of reading from 80 MPa to 140 MPa
0.009% of reading from 140 MPa to 175 MPa
0.015% of reading from 175 MPa to 280 MPa
Oil operated piston gauges
with a base Calibration and Measurement Capability of -
 0.05 kPa
| Accreditation Number: 9727 | Site Number: 9720 | Printed on : 18-Nov-2018

 

--------------------- END OF SCOPE ----------------------