Electronic Standards Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
High frequency electrical metrology - Communications, electromagnetic field strength and EMC test equipment Amplifiers; Attenuators Attenuation Comparison with a reference standard; Comparison with a reference standard by differential measurement

In a coaxial system by scalar measurements

100 kHz to 18 GHz, and

0 to 120 dB

Capability

Attenuators and amplifiers

with Calibration and Measurement Capability of - 

0.25 dB from 0 to 30 dB and 100 kHz to 300 kHz ;

0.2 dB from 0 to 30 dB and 300 kHz to 2.5 MHz ;

0.15 dB from 0 to 40 dB and 2.5 MHz to 1300 MHz ;

0.2 dB from 40 to 80 dB and 2.5 MHz to 1300 MHz ;

0.25 dB from 80 to 120 dB and 2.5 MHz to 1300 MHz ;

0.25 dB from 0 to 30 dB and 1.3 to 8 GHz ; 

0.3 dB from 0 to 30 dB and 8 to 10 GHz ; 

0.4 dB from 0 to 30 dB and 10 to 12 GHz ; 

0.45 dB from 0 to 30 dB and 12 to 18 GHz 

Impedance and reflection measuring equipment Reflection coefficient Comparison with a reference standard; Direct measurement by electrical input

In a coaxial system by scalar measurements

VSWR and return loss, 30 kHz to 18 GHz; 

Directivity and source match measurement, 10 MHz to 18 GHz;

Source match from 2 to 18 GHz in the range 10 dB match to greater or equal to 30 dB match

Capability

with Calibration and Measurement Capability of - 

VSWR and return loss measuring equipment

0.021+0.08 ρ2 for reflection coefficient from 30 kHz to 250 MHz ;

0.014+0.021 ρ2 for reflection coefficient from 250 MHz to 18 GHz

Directivity and source match measurement

0.015 equivalent reflection coefficient from 10 MHz to 2 GHz ;

0.006 equivalent reflection coefficient from 2 GHz to 18 GHz

Source match from 2 to 18 GHz

0.175 equivalent reflection coefficient for 10 dB match ;

0.052 equivalent reflection coefficient for 15 dB match ;

0.023 equivalent reflection coefficient for 20 dB match ;

0.017 equivalent reflection coefficient for 25 dB match ;

0.015 equivalent reflection coefficient for ≥ 30 dB match 

Time and frequency metrology - Frequency and time standards Frequency standards Frequency Comparison with a reference standard; Direct measurement

at 1, 2, 2.5, 5 and 10 MHz

Capability

with Calibration and Measurement Capability of - 

2 in 1011 at 1, 2, 2.5, 5 and 10 MHz

Signal sources Frequency; Power; Voltage Comparison with a reference standard; Direct measurement

Frequency characteristics from 10 Hz to 40 GHz ;

Power measurements from 0 to -120 dBm ; 1mW to 30 W and 30 kHz to 40 GHz ; 

Pulse characteristics from 0.10 ns to 1 s ;

Measurement of internal D.C. voltage and current in accordance with manufacturers' handbook - 

DC Volts from 10 mV to 1000 V ;

DC Current from 1 mA to 3 A

Capability

Frequency characteristics

with Calibration and Measurement Capability of - 

5 in 106 from 10 to 100 Hz ;
5 in 107 from 100 Hz to 1 kHz ;
5 in 108 from 1 to 10 kHz ;
5 in 109 from 10 to 100 kHz ;
5 in 1010 from 100 kHz to 1 MHz ;
6 in 1011 from 1 to 10 MHz ;
4 in 1011 from 10 MHz to 3 GHz ;
3 in 1010 from 3 to 10 GHz ;
1 in 1010 from 10 to 20 GHz ;
5 in 1011 from 20 to 30 GHz ;
3 in 1011 from 30 to 40 GHz

Power measurements

with Calibration and Measurement Capability of - 

0.6% at 1 mW and 50 MHz ;

2.7% from 1 to 100 W and 1.8 MHz to 1 GHz ;

3.7% from 0 to 35 dBm and 30 kHz to 50 kHz ;

2.9% from 0 to 35 dBm and 50 kHz to 4.2 GHz ;

3.1% from -20 to -10 dBm and 10 to 30 MHz ;

2.8% from -20 to -10 dBm and 30 MHz to 2 GHz ;

3.3% from -20 to -10 dBm and 2 to 12.4 GHz ;

3.7% from -20 to -10 dBm and 12.4 to 18 GHz ;

2.5% from -10 to +20 dBm and 10 to 30 MHz ;

2.1% from -10 to +20 dBm and 30 MHz to 2 GHz ;

2.8% from -10 to +20 dBm and 2 to 12.4 GHz ;

3.2% from -10 to +20 dBm and 12.4 to 18 GHz ;

4.3% from -20 to +20 dBm and 18 to 26 GHz ;

4.8% from -20 to +20 dBm and 26 to 38 GHz ;

5.6% from -20 to +20 dBm and 38 to 40 GHz ;

3.7% from -50 to -20 dBm and 10 to 30 MHz ;

3.6% from -50 to -20 dBm and 30 MHz to 2 GHz ;

5.5% from -50 to -20 dBm and 2 to 18 GHz ;

7.3% from -50 to -20 dBm and 18 to 33 GHz ;

7.7% from -50 to -20 dBm and 33 to 40 GHz ;

5.1% from -60 to -50 dBm and 10 to 30 MHz ;

5.0% from -60 to -50 dBm and 30 MHz to 2 GHz ;

5.6% from -60 to -50 dBm and 2 to 18 GHz ;

7.3% from -60 to -50 dBm and 18 to 33 GHz ;

8.0% from -60 to -50 dBm and 33 to 40 GHz ;

4.4% from -40 to 0 dBm and 2.5 to 1300 MHz ;

4.7% from -80 to -40 dBm and 2.5 to 1300 MHz ;

8.6% from -120 to -80 dBm and 2.5 to 1300 MHz

Pulse characteristics 

with Calibration and Measurement Capability of - 

0.2 ns or 0.002% (whichever is greater) for pulse spacing ;

1.2 ns or 0.002% (whichever is greater) for pulse width ;

0.4 ns or 0.004% (whichever is greater) for rise time

Measurement of internal instrument parameters

with Calibration and Measurement Capability of - 

DC Volts 0.015% of reading + 5 μV ;

DC Current 0.2% of reading + 2 μA

Time and frequency metrology - Frequency, time and waveform measuring equipment Counters Frequency Comparison with a reference standard; Direct measurement

Counters from 10 Hz to 40 GHz;

Capability

Counters

with Calibration and Measurement Capability of -
5 in 106 from 10 to 100 Hz ;
5 in 10from 100 Hz to 1 kHz ;
5 in 108 from 1 to 10 kHz ;
5 in 109 from 10 to 100 kHz ;
5 in 1010 from 100 kHz to 1 MHz ;
6 in 1011 from 1 to 10 MHz ;
4 in 1011 from 10 MHz to 3 GHz ;
3 in 1010 from 3 to 10 GHz ;
1 in 1010 from 10 to 20 GHz ;
5 in 1011 from 20 to 30 GHz ;
3 in 1011 from 30 to 40 GHz