SERVICE | PRODUCT | DETERMINANT | TECHNIQUE | PROCEDURE | LIMITATION / RANGE | DC and low frequency electrical metrology - Electrical measurement and test equipment
| Digital multimeters (DMM); Ohm meters;
| Resistance;
| Comparison with a reference standard; | | | | CAPABILITY With Calibration and Measurement Capability of - 7 mμ at 100 mμ, 1 μ, 10 μ 0.011 μ at 100 μ 0.083 μ at 1 kμ 0.82 μ at 10 kμ 0.004 kμ at 100 kμ 0.00015 Mμ at 1 Mμ 0.0039 Mμ at 10 Mμ 0.52 Mμ at 100 Mμ
|
| Digital multimeters (DMM); Voltmeters;
| AC voltage; DC voltage;
| Comparison with a reference standard; | | | | CAPABILITY With Calibration and Measurement Capability of -
DC Voltage 0.004 % + 3 μV from 0 to 200 mV 0.003 % + 4 μV from 200 mV to 2 V 0.003 % + 40 μV from 2 V to 20 V 0.003 % + 0.4 mV from 20 V to 200 V 0.003 % + 4 mV from 200 V to 1000 V
AC Voltage 0.032 % + 20 μV from 20 mV to 200 mV and from 45 Hz to 1 kHz, 0.033 % + 90 μV from 200 mV to 2 V and from 45 Hz to 1 kHz, 0.031 % + 1 mV from 2 V to 20 V and from 45 Hz to 1 kHz, 0.035 % + 8 mV from 20 V to 200 V and from 45 Hz to 1 kHz, 0.036 % + 75 mV from 200 V to 700 V and from 45 Hz to 1 kHz.
0.07 % + 35 μV from 20 mV to 200 mV and from 1 kHz to 20 kHz, 0.06 % + 135 μV from 200 mV to 2 V and from 1 kHz to 20 kHz, 0.05 % + 2 mV from 2 V to 20 V and from 1 kHz to 20 kHz. 0.09 % + 40 mV from 20 V to 200 V and from 1 kHz to 20 kHz, 0.13 % + 400 mV from 200 V to 700 V and from 1 kHz to 10 kHz.
0.3 % + 70 μV from 20 mV to 200 mV and from 20 kHz to 100 kHz, 0.22 % + 2 mV from 200 mV to 2 V and from 20 kHz to 100 kHz. 0.18 % + 33 mV from 2 V to 20 V and from 20 kHz to 100 kHz.
|
| Ammeters; Digital multimeters (DMM);
| AC current; DC current;
| Comparison with a reference standard; | | | | CAPABILITY With Calibration and Measurement Capability of -
D.C. current 0.01 % + 30 nA from 0 to 200 μA, 0.0009 % + 40 nA from 200 μA to 2 mA, 0.007 % + 0.3 μA from 2 mA to 20 mA, 0.008 % + 3 μA from 20 mA to 200 mA, 0.014 % + 35 μA from 200 mA to 2 A, 0.032 % + 0.35 mA from 2 A to 10 A
A.C. current 0.10% + 0.25 μA from 25 μA to 100 μA and from 45 Hz to 1 kHz, 0.09% + 0.5 μA from 100 μA to 1 mA and from 45 Hz to 1 kHz, 0.08% + 4 μA from 1 mA to 10 mA and from 45 Hz to 1 kHz, 0.09% + 40 μA from 10 mA to 100 mA and from 45 Hz to 1 kHz, 0.10% + 400 uA from 100 mA to 1 A and from 45 Hz to 1 kHz, 0.06% + 2 mA from 1 A to 10 A and from 45 Hz to 100 Hz,
1.30% + 0.25 μA from 25 μA to 100 μA and from 1 kHz to 2 kHz, 0.70% + 0.7 μA from 100 μA to 1 mA and from 1 kHz to 2 kHz, 0.46 % + 7 μA from 1 mA to 10 mA and from 1 kHz to 2 kHz, 0.46 % + 70 μA from 10 mA to 100 mA and from 1 kHz to 2 kHz, 0.60% + 700 μA from 100 mA to 1 A and from 1 kHz to 2 kHz, 0.30 % + 4 mA from 1 A to 10 A and from 100 Hz to 1 kHz,
|
|