Back to Search Results


Address Details:
2/112 Fison Avenue West
EAGLE FARM, QLD 4009
AUSTRALIA Map
www.ipipe.com.au

Contact Details:
Mr William Gadsby
+61(07) 32524337

Availability:
Services conditionally available to external clients

SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.


  • ISO/IEC 17025 (2005)
    Infrastructure and Asset Integrity
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    Evaluation of mechanical performance of pressure plant, pipelines and equipment
    High pressure oil and gas pipelines;
    Hydrostatic pressure; Leakage; Pneumatic pressure;
    Not applicable;
    AS 2885.5 Type 1A
    above ground piping only up to 70000 kPa

    Low pressure oil and gas pipelines;
    Hydrostatic pressure; Leakage; Pneumatic pressure; Strength of assembly;
    Not applicable;
    APGA-CoP
    above ground pipelines only

    Hose and hose assemblies; Piping; Pressure fittings; Valves;
    Hydrostatic pressure;
    Not applicable;
    AS 1180.5, AS 2117, AS 3791, AS 4037, AS 4041, ASME B31.1, ASME B31.3, ASTM E1003; pressure relief valves - API 526, API 527; API 598 
    up to 70000 kPa


    Pneumatic pressure;
    Not applicable;
    API 526, API 527, API 598, AS 1180.5, AS 3791, AS 4037, AS 4041, ASME B31.3

    Water pipelines;
    Hydrostatic pressure; Leakage; Pneumatic pressure;
    Not applicable;
    AS/NZS 2566.2, APGA-CoP (upstream polyethylene gathering networks - CSG industry)
    Up to 70000 kPa