Back to Search Results


Address Details:
Unit 18, 88 Merrindale Drive
CROYDON SOUTH, VIC 3136
AUSTRALIA Map
www.emcbayswater.com.au

Contact Details:
Mr Neville Liyanapatabendige
+61(03) 97615888

Availability:
Services available to external clients

SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.



ISO/IEC 17025 (2017)
Manufactured Goods
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
Assessment of emissions and immunity - EMC emission standards
Vehicles, boats and internal combustion engine driven equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS CISPR 12 ; 
CISPR 12 ; 
EN 55012 ;
EN 55025
excluding insertion loss of ignition noise suppressors

Industrial, scientific and medical (ISM) radio-frequency equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZSCISPR 11 ; 
CISPR 11 ; 
EN 55011 ;
ICES-001 ;
CAN/CSA-CEI/IEC CISPR 11
excluding measurements below 9 kHz


Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS CISPR 25 and CISPR 25

Residential, commercial and light industrial environments;
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS 61000.6.3 ;
EN 61000-6-3 ; 
IEC 61000-6-3 ;
BS EN 50491-5-2 ;

Medical electrical equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
IEC 60601-1-2 ; 
EN 60601-1-2

Aerospace and military grade equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
MIL-STD-461D, E and F methods CE101, CE102, RE101 and RE102

Electrical equipment for measurement, control and laboratory use;
Conducted emissions; Conducted interference;
Not applicable;
AS/NZS CISPR 11;CISPR 11; EN 55011 excluding measurements below 9 kHz


Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
IEC 61326-1; EN 61326-1

Information technology equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS CISPR 22 ;
CISPR 22 ; 
EN 55022 ;
ICES-003 ;
CAN/CSA-CEI/IEC CISPR 22

Information technology equipment; Multimedia equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS CISPR 32, CISPR 32 and EN 55032

Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen;
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
EN 50270

Electrical lighting and similar equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS CISPR 15, CISPR 15 and EN 55015

Sound and television broadcast receivers and associated equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS CISPR 13, CISPR 13 and EN 55013

Railway electronic equipment used on rolling stock; Rolling stock - Train and complete vehicle;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
EN 50121-3-2
EN 50155 clause 5.4 and 5.5 [referencing clause 12.2.7 and 12.2.8]

Audio, video, audio-visual and entertainment lighting control apparatus for professional use;
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
EN 55103-1 Excluding testing of harmonics and flicker with products >16 Amps mains supply

Road traffic signal systems and devices;
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
EN 50293
EN 50556 clause 6.7

Electrical and electronic products;
Mains harmonics and flicker;
Not applicable;
AS/NZS 61000.3.2 ;
EN 61000-3-2 ;
AS/NZS 61000.3.3 ; 
EN 61000-3-3

Electrical and electronic products; Information technology equipment;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
ANSI C63.4: 2014 for unintentional emitters ;
ANSI C63.10: 2013 for intentional radiators ; 
Unintentional Radiators described in FCC Part 15, Subpart B using ANSI C63.4-2014 ; 
Intentional radiators described in FCC part 15, Subpart C using ANSI C63.4-2014 and ANSI C63.10-2013 ;
KDB Guidelines : KDB 789033 D02, KDB 558074 D01, and KDB 905462 ; 
ICES-003 ; 
RSS-210 ;
RSS-247 ; 
RSS-GEN
Frequency range of 9 kHz to 40 GHz



Radiated Measurements conducted at 3 metre iOATS Semi Anechoic Chamber Croydon South

Electrical and electronic products; Power tools - Electric;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS CISPR 14-1, CISPR 14-1 and EN 55014-1

Machine tools;
Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS CISPR 11, CISPR 11, EN 55011 
excluding measurements below 9 kHz

Railway vehicles and equipment including railway signalling and telecommunications equipment;
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
EN 50121-4

In-vitro diagnostic (IVD) medical equipment;
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
IEC 61326-2-6; EN 61326-2-6

Industrial environments;
Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS 4251.1 ;
AS/NZS 4251.2 ; 
AS/NZS 61000.6.4 ; 
EN 61000-6-4 ;
IEC 61000-6-4

Radio equipment;
Conducted and radiated emissions; Conducted emissions; Radiated emissions; Radiated interference;
Not applicable;
ETSI EN 300 328 
all tests applicable to transmitters with output power of less than and including 10 dBm EIRP


Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS 4268 in the frequency range 9 kHz to 26.5 GHz


Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
Not applicable;
ETSI EN 301 489-1


Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
Not applicable;
AS/NZS 4268

Shielded enclosures;
Attenuation performance;
Not applicable;
MIL-STD-285
IEEE Std 299
Assessment of emissions and immunity - EMC immunity standards
Gaming machines;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
AS/NZS GMNS clauses 2.3.52 to 2.3.59

Residential, commercial and light industrial environments;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 61000-6-1 ;
AS/NZS 61000.6.1 ;
IEC 61000-6-1 ;
EN 50491-5-2

Medical electrical equipment;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
IEC 60601-1-2, EN 60601-1-2

Aerospace and military grade equipment;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
MIL-STD-461 D, E and F methods CS 101, CS 106, CS 109, CS 114, RS 101 and RS 103

Electrical equipment for measurement, control and laboratory use;
Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 50270


Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 61326-1; IEC 61326-1

Information technology equipment;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
AS/NZS CISPR 24; CISPR 24; EN 55024

Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 50270

Electrical relays; Measuring relays and protection equipment;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
IEC 60225-22-6

Electrical lighting and similar equipment;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 61547


Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity;
Not applicable;
EN 55103-2

Railway electronic equipment used on rolling stock;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 50155 Clause 5.4 and 5.5 [referencing clause 12.2.7 and 12.2.8]

Railway electronic equipment used on rolling stock; Rolling stock - Train and complete vehicle;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 50121-3-2

Audio, video, audio-visual and entertainment lighting control apparatus for professional use;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 55103-2

Road traffic signal systems and devices;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Surge immunity; Voltage short dips and interruptions; Voltage spikes;
Not applicable;
EN 50293
EN 50556 clause 6.7


Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity;
Not applicable;
EN 50293
EN 50556 clause 6.7

Electrical and electronic products;
Pulsed magnetic field;
Not applicable;
EN 61000-4-9 ;
IEC 61000-4-9 ;
AS/NZS 61000.4.9 ;


Radiated radio-frequency;
Not applicable;
IEC 61000-4-3 ;
EN 61000-4-3 ; 
AS/NZS 61000.4.3 


Electrical fast transient;
Not applicable;
EN 61000-4-4 ;
IEC 61000-4-4 ;
AS/NZS 61000.4.4 ;
IEC 60335-1 Section 19.11.4.3


Power frequency magnetic field;
Not applicable;
EN 61000-4-8 ;
IEC 61000-4-8 ; 
AS/NZS 61000.4.8 


Electrostatic discharge;
Not applicable;
EN 61000-4-2 ;
IEC 61000-4-2 ;
AS/NZS 61000.4.2 ;
IEC 60335-1 Section 19.11.4.1


Conducted disturbance; Induced signal susceptibility;
Not applicable;
EN 61000-4-6 ;
IEC 61000-4-6 ;
AS/NZS 61000.4.6 ;
IEC 60335-1 Section 19.11.4.5


Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 61000-4-11 ;
IEC 61000-4-11 ;
AS/NZS 61000.4.11 ;
IEC 60335-1 Section 19.11.4.6
For appliances having a rated current not exceeding 16 A


Surge immunity;
Not applicable;
EN 61000-4-5 ;
IEC 61000-4-5 ;
AS/NZS 61000.4.5 ;
IEC 60335-1 Section 19.11.4.4

Electrical and electronic products; Information technology equipment; Radio equipment; Telecommunication network equipment;
Radiated radio-frequency;
Not applicable;
IEC 61000-4-3; 
EN 61000-4-3 ;
AS/NZS 61000.4.3 ;
IEC 60335-1 Section 19.11.4.2

Electrical and electronic products; Power tools - Electric;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 55014-2; AS/NZS CISPR 14-2, CISPR 14-2

Machine tools;
Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity;
Not applicable;
EN 50370-2


Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 50370-2

Railway vehicles and equipment including railway signalling and telecommunications equipment;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 50121-4


Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Radiated susceptibility;
Not applicable;
EN 50121-3-2
EN 50121-4
EN 50155 clause 5.4 and 5.5 [referencing clause 12.2.7 & 12.2.8]

In-vitro diagnostic (IVD) medical equipment;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 61326-2-6; EN 61326-2-6

Industrial environments;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 61000-6-2, AS/NZS 61000.6.2, IEC 61000-6-2

Radio equipment;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
ETSI EN 301 489-1

Components of fire, intruder and social alarm systems;
Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
Not applicable;
EN 50130-4


Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity;
Not applicable;
EN 50130-4 [excluding testing using EN 61000-4-20 methodology] Excluding testing using EN 61000-4-20 methodology
Assessment of emissions and immunity - Non-ionising radiation strength and hazard assessment
Antennas; Broadcast and telecommunication equipment installations; Hand held and wireless communication devices;
Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields; Radiated field strength measurements;
Not applicable;
Canadian Standard RSS-102 (RF Exposure Evaluation and Nerve Stimulation - for external fields only, excluding SAR measurements)