SERVICE | PRODUCT | DETERMINANT | TECHNIQUE | PROCEDURE | LIMITATION / RANGE |
Assessment of emissions and immunity - EMC emission standards
| Vehicles, boats and internal combustion engine driven equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS CISPR 12 ; CISPR 12 ; EN 55012 ; EN 55025 | excluding insertion loss of ignition noise suppressors |
|
| Industrial, scientific and medical (ISM) radio-frequency equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZSCISPR 11 ; CISPR 11 ; EN 55011 ; ICES-001 ; CAN/CSA-CEI/IEC CISPR 11 | excluding measurements below 9 kHz |
|
|
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS CISPR 25 and CISPR 25 | |
|
| Residential, commercial and light industrial environments;
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS 61000.6.3 ; EN 61000-6-3 ; IEC 61000-6-3 ; BS EN 50491-5-2 ;
| |
|
| Medical electrical equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | IEC 60601-1-2 ; EN 60601-1-2 | |
|
| Aerospace and military grade equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | MIL-STD-461D, E and F methods CE101, CE102, RE101 and RE102 | |
|
| Electrical equipment for measurement, control and laboratory use;
| Conducted emissions; Conducted interference;
| Not applicable; | AS/NZS CISPR 11;CISPR 11; EN 55011 | excluding measurements below 9 kHz |
|
|
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | IEC 61326-1; EN 61326-1 | |
|
| Information technology equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS CISPR 22 ; CISPR 22 ; EN 55022 ; ICES-003 ; CAN/CSA-CEI/IEC CISPR 22 | |
|
| Information technology equipment; Multimedia equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS CISPR 32, CISPR 32 and EN 55032 | |
|
| Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen;
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | EN 50270 | |
|
| Electrical lighting and similar equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS CISPR 15, CISPR 15 and EN 55015 | |
|
| Sound and television broadcast receivers and associated equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS CISPR 13, CISPR 13 and EN 55013 | |
|
| Railway electronic equipment used on rolling stock; Rolling stock - Train and complete vehicle;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | EN 50121-3-2 EN 50155 clause 5.4 and 5.5 [referencing clause 12.2.7 and 12.2.8] | |
|
| Audio, video, audio-visual and entertainment lighting control apparatus for professional use;
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | EN 55103-1 | Excluding testing of harmonics and flicker with products >16 Amps mains supply |
|
| Road traffic signal systems and devices;
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | EN 50293 EN 50556 clause 6.7 | |
|
| Electrical and electronic products;
| Mains harmonics and flicker;
| Not applicable; | AS/NZS 61000.3.2 ; EN 61000-3-2 ; AS/NZS 61000.3.3 ; EN 61000-3-3 | |
|
| Electrical and electronic products; Information technology equipment;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | ANSI C63.4: 2014 for unintentional emitters ; ANSI C63.10: 2013 for intentional radiators ; Unintentional Radiators described in FCC Part 15, Subpart B using ANSI C63.4-2014 ; Intentional radiators described in FCC part 15, Subpart C using ANSI C63.4-2014 and ANSI C63.10-2013 ; KDB Guidelines : KDB 789033 D02, KDB 558074 D01, and KDB 905462 ; ICES-003 ; RSS-210 ; RSS-247 ; RSS-GEN | Frequency range of 9 kHz to 40 GHz |
|
|
| Radiated Measurements conducted at 3 metre iOATS Semi Anechoic Chamber Croydon South | | |
|
| Electrical and electronic products; Power tools - Electric;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS CISPR 14-1, CISPR 14-1 and EN 55014-1 | |
|
| Machine tools;
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS CISPR 11, CISPR 11, EN 55011
| excluding measurements below 9 kHz |
|
| Railway vehicles and equipment including railway signalling and telecommunications equipment;
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | EN 50121-4 | |
|
| In-vitro diagnostic (IVD) medical equipment;
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | IEC 61326-2-6; EN 61326-2-6 | |
|
| Industrial environments;
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS 4251.1 ; AS/NZS 4251.2 ; AS/NZS 61000.6.4 ; EN 61000-6-4 ; IEC 61000-6-4 | |
|
| Radio equipment;
| Conducted and radiated emissions; Conducted emissions; Radiated emissions; Radiated interference;
| Not applicable; | ETSI EN 300 328
| all tests applicable to transmitters with output power of less than and including 10 dBm EIRP |
|
|
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS 4268 | in the frequency range 9 kHz to 26.5 GHz |
|
|
| Conducted emissions; Conducted interference; Mains harmonics and flicker; Radiated emissions; Radiated interference;
| Not applicable; | ETSI EN 301 489-1
| |
|
|
| Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
| Not applicable; | AS/NZS 4268 | |
|
| Shielded enclosures;
| Attenuation performance;
| Not applicable; | MIL-STD-285 IEEE Std 299
| |
|
Assessment of emissions and immunity - EMC immunity standards
| Gaming machines;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | AS/NZS GMNS clauses 2.3.52 to 2.3.59 | |
|
| Residential, commercial and light industrial environments;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 61000-6-1 ; AS/NZS 61000.6.1 ; IEC 61000-6-1 ; EN 50491-5-2 | |
|
| Medical electrical equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | IEC 60601-1-2, EN 60601-1-2 | |
|
| Aerospace and military grade equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | MIL-STD-461 D, E and F methods CS 101, CS 106, CS 109, CS 114, RS 101 and RS 103 | |
|
| Electrical equipment for measurement, control and laboratory use;
| Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 50270 | |
|
|
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 61326-1; IEC 61326-1 | |
|
| Information technology equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | AS/NZS CISPR 24; CISPR 24; EN 55024 | |
|
| Information technology equipment; Multimedia equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | CISPR 35; EN 55035 | Excluding Broadband impulsive conducted disturbances test
|
|
| Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 50270 | |
|
| Electrical relays; Measuring relays and protection equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | IEC 60225-22-6 | |
|
| Electrical lighting and similar equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 61547 | |
|
|
| Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity;
| Not applicable; | EN 55103-2 | |
|
| Railway electronic equipment used on rolling stock;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 50155 Clause 5.4 and 5.5 [referencing clause 12.2.7 and 12.2.8] | |
|
| Railway electronic equipment used on rolling stock; Rolling stock - Train and complete vehicle;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 50121-3-2 | |
|
| Audio, video, audio-visual and entertainment lighting control apparatus for professional use;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 55103-2 | |
|
| Road traffic signal systems and devices;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Surge immunity; Voltage short dips and interruptions; Voltage spikes;
| Not applicable; | EN 50293 EN 50556 clause 6.7 | |
|
|
| Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity;
| Not applicable; | EN 50293 EN 50556 clause 6.7 | |
|
| Electrical and electronic products;
| Pulsed magnetic field;
| Not applicable; | EN 61000-4-9 ; IEC 61000-4-9 ; AS/NZS 61000.4.9 ; | |
|
|
| Radiated radio-frequency;
| Not applicable; | IEC 61000-4-3 ; EN 61000-4-3 ; AS/NZS 61000.4.3 | |
|
|
| Electrical fast transient;
| Not applicable; | EN 61000-4-4 ; IEC 61000-4-4 ; AS/NZS 61000.4.4 ; IEC 60335-1 Section 19.11.4.3 | |
|
|
| Power frequency magnetic field;
| Not applicable; | EN 61000-4-8 ; IEC 61000-4-8 ; AS/NZS 61000.4.8 | |
|
|
| Electrostatic discharge;
| Not applicable; | EN 61000-4-2 ; IEC 61000-4-2 ; AS/NZS 61000.4.2 ; IEC 60335-1 Section 19.11.4.1 | |
|
|
| Conducted disturbance; Induced signal susceptibility;
| Not applicable; | EN 61000-4-6 ; IEC 61000-4-6 ; AS/NZS 61000.4.6 ; IEC 60335-1 Section 19.11.4.5 | |
|
|
| Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 61000-4-11 ; IEC 61000-4-11 ; AS/NZS 61000.4.11 ; IEC 60335-1 Section 19.11.4.6 | For appliances having a rated current not exceeding 16 A |
|
|
| Surge immunity;
| Not applicable; | EN 61000-4-5 ; IEC 61000-4-5 ; AS/NZS 61000.4.5 ; IEC 60335-1 Section 19.11.4.4 | |
|
| Electrical and electronic products; Information technology equipment; Radio equipment; Telecommunication network equipment;
| Radiated radio-frequency;
| Not applicable; | IEC 61000-4-3; EN 61000-4-3 ; AS/NZS 61000.4.3 ; IEC 60335-1 Section 19.11.4.2 | |
|
| Electrical and electronic products; Power tools - Electric;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 55014-2; AS/NZS CISPR 14-2, CISPR 14-2 | |
|
| Machine tools;
| Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity;
| Not applicable; | EN 50370-2 | |
|
|
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 50370-2 | |
|
| Railway vehicles and equipment including railway signalling and telecommunications equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 50121-4 | |
|
|
| Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Induced signal susceptibility; Radiated susceptibility;
| Not applicable; | EN 50121-3-2 EN 50121-4 EN 50155 clause 5.4 and 5.5 [referencing clause 12.2.7 & 12.2.8] | |
|
| In-vitro diagnostic (IVD) medical equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 61326-2-6; EN 61326-2-6 | |
|
| Industrial environments;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 61000-6-2, AS/NZS 61000.6.2, IEC 61000-6-2 | |
|
| Radio equipment;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | ETSI EN 301 489-1 | |
|
| Components of fire, intruder and social alarm systems;
| Conducted disturbance; Electrical fast transient; Electrostatic discharge; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions;
| Not applicable; | EN 50130-4 | |
|
|
| Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Surge immunity;
| Not applicable; | EN 50130-4 [excluding testing using EN 61000-4-20 methodology] | Excluding testing using EN 61000-4-20 methodology |
|
Assessment of emissions and immunity - Non-ionising radiation strength and hazard assessment
| Antennas; Broadcast and telecommunication equipment installations; Hand held and wireless communication devices;
| Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields; Radiated field strength measurements;
| Not applicable; | Canadian Standard RSS-102 (RF Exposure Evaluation and Nerve Stimulation - for external fields only, excluding SAR measurements) | |
|