SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.


  • ISO/IEC 17025 (2005) - The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
    Calibration
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    DC and low frequency electrical metrology - Electrical measurement and test equipment
    Insulation resistance test equipment;
    Resistance;
    Direct measurement against a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.04% from 30 Ω to 199.9 Ω
    0.12% from 200 Ω to 499 Ω
    0.04% from 500 Ω to 1.999 kΩ
    0.12% from 2.00 kΩ to 4.99 kΩ
    0.06% from 5.00 kΩ to 10 kΩ
    0.03% from 10 kΩ to 39.99 kΩ at 55 V
    0.02% from 40 kΩ to 99.99 kΩ at 400 V
    0.03% from 100 kΩ to 199.99 kΩ at 800 V
    0.02% from 200 kΩ to 999. 9 kΩ at 1100 V
    0.2% from 1 MΩ to 9.999 MΩ at 1150 V
    1.0% from 10 MΩ to 99.99 MΩ at 1570 V
    2.1% from 100 MΩ to 999.9 MΩ at 1570 V


    Ammeters;
    AC current; DC current;
    Direct measurement against a reference standard;
    By methods of -
    in-house method LMS-P-ELC-09 Calibration of clamp meters/Tong Testers
    CAPABILITY
    D.C. ammeters
    with Calibration and Measurement Capability of-
    0.02% from 100 μA to 1 A
    0.03% from 1 A to 10 A
    0.5% plus 0.1 A from 10 A to 50 A
    0.5% plus 0.05 A from 50 A to 100 A
    0.5% plus 0.2 A from 100 A to 300 A
    0.5% from 300 A to 500 A
    A.C. ammeters
    with Calibration and Measurement Capability of-
    0.02% from 10 mA to 10 A at 50 Hz and 1 KHz
    Non Toroidal clamps using multiple turn technique
    with Calibration and Measurement Capability of-
    0.5% plus 0.2 A at 50 Hz from 10 A to 100 A
    0.8% at 50 Hz from 100 A to 200 A
    0.7% at 50 Hz from 200 A to 300 A
    0.65% at 50 Hz from 300 A to 400 A
    0.6% at 50 Hz from 400 A to 500 A
    0.5% plus 0.3 A at 400 Hz from 10 A to 30 A
    0.5% plus 0.35 A at 400 Hz from 30 A to 50 A
    0.5% plus 0.4 A at 400 Hz from 50 A to 70 A
    0.8% plus 0.2 A at 400 Hz from 70 A to 100 A
    1.0% plus 0.3 A at 400 Hz from 100 A to 200 A
    1.0% plus 0.1 A at 400 Hz from 200 A to 300 A
    0.95% at 400 Hz from 300 A to 500 A


    Ohm meters;
    Resistance;
    Direct measurement against a reference standard;
    By the methods of -
    in-house method LMS-P-ELC-01 Calibration of Digital Multimeters
    CAPABILITY
    with Calibration and Measurement Capability of -
    1% from 0.001 Ω to 0.009 Ω
    0.1% from 0.01 Ω to 0.09 Ω
    0.02% from 0.1 Ω to 0.9 Ω
    0.006% from 1 Ω to 9 Ω
    0.02% from 10 Ω to 1 MΩ
    0.2% from 10 MΩ to 100 MΩ


    Voltmeters;
    AC voltage; DC voltage;
    Direct measurement against a reference standard;
    CAPABILITY
    DC Voltmeters
    with Calibration and Measurement Capability of-
    0.002% at 100 mV
    0.001% from 1 V to 100 V
    0.002% from 100 V to 1000 V
    AC voltmeters
    with Calibration and Measurement Capability of -
    0.02% from 100 mV to 100V at 50 Hz and 1 kHz
    0.01% from 100 V to 1000 V at 50 Hz and 1 kHz
    DC and low frequency electrical metrology - Electrical standards
    Resistance boxes;
    Resistance;
    Direct measurement against a reference standard;
    By the methods of-
    in-house method LMS-P-ELC-11 Calibration of resistance boxes
    Resistance boxes only from 0.001 Ω to 100 MΩ
    CAPABILITY
    with Calibration and Measurement Capability of -
    1% from 0.001 Ω to 0.009 Ω
    0.1% from 0.01 Ω to 0.09 Ω
    0.02% from 0.1 Ω to 0.9 Ω
    0.006% from 1 Ω to 9 Ω
    0.02% from 10 Ω to 1 MΩ
    0.2% from 10 MΩ to 100 MΩ 
    Pressure metrology - Pressure and vacuum measuring equipment
    Digital pressure gauges; Mechanical pressure gauges; Vacuum gauges;
    Gauge pressure;
    Comparison with reference instrument;
    By the methods of –
    AS 1349 and the Metrology Society of Australia (MSA) Test Methods 1 and 2
    Gauge pressure calibration including test gauges and digital indicators in the range -80 kPa to 70 MPa
    CAPABILITY
    With Calibration and Measurement Capability of -
    0.06 kPa from -80 kPa to 700 kPa
     1.9 kPa from 700 kPa to 7,000 kPa
     2.0 kPa from 7,000 kPa to 14,000 kPa
      0.01 MPa from 14 MPa to 70 MPa
    Temperature metrology - Non-contact temperature measuring equipment
    Radiation pyrometers; Thermal imaging systems;
    Temperature;
    To be determined;
    Calibration of non-contact thermometers and thermal imaging cameras (8-14 μm)
    At 0 ºC and from 35 ºC to 500 ºC
    CAPABILITY
    With Calibration and Measurement Capability of -
     0.7 ºC at 0 ºC
     0.7 ºC + 0.20%T from 35 ºC to 100 ºC
     0.7 ºC + 0.35%T from 100 ºC to 200 ºC
     0.7 ºC + 0.4%T from 200 ºC to 350 ºC
     0.7 ºC + 0.36%T from 350 ºC to 500 ºC