Back to Search Results


Address Details:
Unit 17, 15 Suscatand Street
ROCKLEA, QLD 4106
AUSTRALIA Map
www.antl.com.au

Contact Details:
Mr Jeffrey Profke
+61(07) 32740737

Availability:
Services available to external clients

SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.


  • ISO/IEC 17025 (2005)
    Infrastructure and Asset Integrity
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    Evaluation of mechanical performance of pressure plant, pipelines and equipment
    Hose and hose assemblies; Waste disposal fittings;
    Abrasion resistance; Ageing; Burst pressure; Dimensional stability; Dispersal rate of a hose reel discharge; Distortion; Ease of opening a nozzle, other than a twist nozzle, to the open position; Ease of turning a twist nozzle to the open position; Expansion; Flexibility; Flow rate of a hose reel; Hose reel assembly pressure; Hydrostatic pressure; Lining adhesion; Load appraisal of inspection opening and access cover; Pressure loss due to friction; Serviceability after kinking; Strength of assembly;
    Not applicable;
    AS 1180.5; AS/NZS 1221 clauses 2.2.2.2, 2.2.2.3, 3.2.1, 3.2.2.1, 3.2.2.2, 3.2.2.3, 3.2.3, 3.2.4.2, 3.2.4.3, Appendices B, C, D, E, F, G; AS/NZS 2554 clauses 1.6, 2.2.1, 2.2.2, 2.2.3, 2.2.4, 2.3, 2.4, Appendix B; AS 2792 clauses 3.1.2, 3.1.3, 3.1.4, 3.1.5, 3.1.6, 3.1.7, 3.3.1, 3.3.2, 3.3.3, Appendices E, F, G, H, I, K, L, M 

  • ISO/IEC 17025 (2005)
    Manufactured Goods
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    Evaluation of electrical appliances and devices - Performance
    Water heaters;
    Boiling time and efficiency; Electrical energy consumption; Overflow; Pressure measurement; Strength and dimensions of components; Temperature control; Temperature distribution; Torque;
    Not applicable;
    AS 3498 Section 7.2, Appendices A, B, C; AS/NZS 4692.1 Sections 2.2.2, 2.2.3, 2.2.4, 5.2.1, 5.2.3, 5.3, 5.5.2.1, 5.6.5; AS/NZS 6400 Sections 2.1, 2.1.4, 2.2, 2.2.4, 2.3, 2.3.4, 2.4, 2.4.4, 2.5, 2.6,2.6.4, 2.7, 2.7.4
    Material performance evaluation of elastomers, plastics and composite products
    Hosing material; Pipe material and related products;
    Adhesion; Bending properties; Compression; Dimensional stability; Dimensions; Flexing; Formability; Heat resistance; Impact resistance; Pull-out strength; Strength;
    Not applicable;
    AS 2053.1 clauses 8.1, 8.2, 8.3, 8.4, 9.2, 9.3, 9.4, 9.5, 9.6, Appendices A, B, C, D; AS 2053.5 clauses 6, 7, 8, 9, 10, Appendices AA, BB, CC, DD 
    Mechanical performance evaluation of components for building envelopes, framing and interior lining
    Cable trunking systems;
    Cable trunking system cover retention; Cable trunking system supporting capacity; Deflection; Dimensions; Finish; Impact resistance; Resistance to linear deflection; Squareness; Strength at ultimate limit state loading; Structural performance evaluation;
    Not applicable;
    AS/NZS 4296 clauses 8, 9, 10, Appendices D, E, F, G
    Performance evaluation of healthcare equipment and related items
    Medical suction tubing;
    Dimensions; Flow rate; Mass; Vacuum pressure - Degree of collapse;
    Not applicable;
    AS 2120.3 clause 5.2, Appendix A
    Products and appliances connected to the water supply - Physical evaluation
    Sanitary fixtures - Urinals, water closet pan/suites, bidets, douche seats, cisterns and purpose built bathroom modules;
    Discharge; Flush performance; Flush volume; Hydraulic strength; Leakage; Leak tightness; Load; Splash; Wetting;
    Not applicable;
    AS 1172.1 clauses 3.1, 3.2, 3.3, 3.4, 3.5, 3.6, 3.7, 3.8, Appendices A, B, C, D, E, F, G, H; AS 1172 clauses 4.2, 4.3, 4.7, Appendices A, F; AS 1976 clauses 5.2, 5.3, 5.4, Appendices A, B, C; AS/NZS 3662 clauses 5.1, 5.2, 5.3, 5.4, 5.5, Appendices B, C, D, E; AS/NZS 3982 Appendices A, B, C, D; WMTS 5200.004 clauses 9.3, Appendix C; WMTS 5200.020 clauses 9.2, 9.3, 9.4; WMTS 5200.021 clauses 9.2, 9.3; WMTS 5200.051 clause 9.2, Appendix B 
     

    Food waste disposal units;
    Air gap; Back flow; Degree of fineness (FWDU); Drainage;
    Not applicable;
    WMTS 5200.028 clauses 9.1, 9.2, 9.3, 9.4

    Baths, sinks and basins;
    Endurance; Flow rate; Flush performance; Leak tightness; Spread angle; Strength of assembly; Thermal distortion;
    Not applicable;
    AS/NZS 3662 clauses 5.4.1, 5.4.2, 5.4.3, 5.4.4, 5.5, 5.6.1, 5.6.2, Appendices B, C, D, E, F (2005); AS/NZS 3662 clauses 5.5.1, 5.5.2, 5.5.3, 5.5.4, 5.6, 5.7.1, 5.7.2, Appendices B, C, D, E, F; AS 3982 clauses 1.6.1, 1.6.2, 1.6.3, 1.6.4, Appendices A, B, C, D; AS 4775 clauses 6.5.1, 7.3.1, 8.3; AS/NZS 6400 clause 2.1.3

    Water service products - Connectors, filters, fittings, hoses and pipes;
    Air gap; Air separation distance; Bending properties; Compatibility; Crack propagation; Dimensions; Endurance; Flow rate; Functionality; Impact resistance; Joint strength; Leakage; Leak tightness; Load; Ovality; Pressure; Pressure cycling resistance; Rigidity; Seal integrity; Sliding fit; Socket fit; Strength of assembly; Thermal cycling; Thread form evaluation; Torque;
    Not applicable;
    AS/NZS 1260 clauses 3.2.1, 3.2.2; AS 1432 clauses 4.3, 5.4.2; AS/NZS 1462.1 clauses 7, 8, 11; AS/NZS 1462.4, AS/NZS 1462.6; AS/NZS 1462.8; AS/NZS 1462.10; AS/NZS 1462.11; AS/NZS 1462.13; AS/NZS 1462.17; AS/NZS 1462.24; AS/NZS 1462.29; AS/NZS 1477 clauses 3.3.1, 3.3.3, 3.3.6, 3.4.1(b), 3.4.2, 3.4.3, 3.4.4, 3.5.1, 3.5.2; AS 1571 clause 8.2; AS 1589 clauses 1.7.4, 1.7.5, 1.9.2, 1.10, 1.13.3 up to DN 80, 3.3.1, 3.3.2, 3.3.3, 3.3.4, 3.3.5, 3.4.1, 3.4.2, 3.4.3, 3.5.1, 3.6.1, 4.9.1, 4.9.2, Appendices E, G, H;  AS 1926.3 clauses 5, 6.1, 6.2, Appendices A5.1, A5.2, A5.3, A5.4, B; AS 2280 clauses 2.5.2, 3.1, 3.1.1, 3.1.2.1, 3.1.2.2, 3.1.2.3, 3.1.2.4, 3.5.2.1, 3.5.2.2,4.2.2, Appendices F, H; AS 2419.3 clauses 4.2, 4.2.3, 4.2.3, 4.3, 4.3.2, 4.3.3, 4.3.4, 4.3.5, 4.3.6; AS/NZS 2492 clauses 3.8, 3.9; AS 2537 (1994) clauses 11.2.1, 11.2.3, 11.2.4, 11.2.5, 11.2.6, 11.2.7, 11.2.8, 11.2.9; AS/NZS 2537.3; AS/NZS 2642.3 clauses 12.2.1, 12.2.2, 12.2.3, 12.2.4, 12.2.5, 12.2.6, 12.2.7, 12.2., AS 2887 clauses 2.6.1, 2.6.3, 2.6.5; AS 2888.1; AS 2888.2; AS 2888.3; AS 2888.4; AS 2888.5; AS 2888.6; AS 2888.7; AS 2888.8; AS 2888.10; AS 3499 Clauses 8.2, 8.4, 8.5, 8.8, 8.9, Appendix C; AS 3518 (2004); AS 3688 clauses 3.2, 3.4, 3.5, 3.6, 3.7.1, 3.7.2, 3.8, 4.2, 4.3, 4.4, 4.5, 4.6, 4.7, 4.8, Appendices C, D, E, F, G, H, I, J, K, L; AS/NZS 4129 clauses 1.8, 1.13.1, 1.13.2, 2.4.2, 2.4.3, 2.4.4, 2.4.5, 3.4, 3.5, 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6, Appendices D,E; AS/NZS 4130 clauses 9.1, 10.1, 10.2, 10.4; AS/NZS 4327 clauses 4.1, 4.2,Appendices B, C, D, E, F; AS/NZS 4401 clauses 6.2, 6.3, 6.4, 7.2, 8; AS/NZS 4441 clauses 10, 11.1.1, 11.1.2, 13.2, 13.3, 13.4; AS/NZS 4765 clauses 3.2.3, 3.2.4, 3.2.7, 3.2.8, 3.2.9, 3.2.10, 3.3.1, 3.3.2, 3.3.3, Appendices B, D, E; AS/NZS 4793 clauses 4.1.2, 4.1.3, 4.1.5, 4.1.6, 4.4.1; AS/NZS 4798 Clause 3.3, 3.4, 3.5.1, 3.5.2, 4.2, 5.2, 5.3, 5.5, 5.5.5; AS/NZS 5065 clauses 3.3.1, 3.3.2, 3.4.1, 3.4.2, 3.4.3, 5.2; AS 5082.2 clauses 12.1, 12.2, Appendices C, D, E, F, G, H; AS/NZS 6400 clause 2.7.3; WMTS 5200.040 clause 9; WMTS 5200.053; WMTS 5200.475 clauses 9.2, 9.3, Appendices B, C; WMTS 5200.477 clause 9.4, Appendix C; WMTS 5200.482; EN 713; EN 714; EN 1053; EN 1054; EN 1055; EN 12293; EN 12294; EN 12295; ISO 1167.1;  ISO 1167.2; ISO 1167.3; ISO 1167.4;; ISO 3126; ISO 3459; ISO 3501; ISO 3503; ISO 13257; ISO 13479; ISO 13844; ISO 13845; ISO 13846; ISO 13954; ISO 13955; ISO 16422 clauses 10, 11.1.1, 11.1.2, 13.2, 13.3, 13.4; UK-WIS-4-24-01

    Tap assemblies; Valves;
    Back flow; Bending properties; Closing pressure; Compatibility; Dimensions; Distortion; Endurance; Flow rate; Functionality; Hydrostatic pressure; Leakage; Leak tightness; Load; Pressure; Seal integrity; Spread angle; Strength of assembly; Thermal cycling; Torque;
    Not applicable;
    AS 1357.2 clauses 3.2, 3.3, 7.2, 7.3, 7.4, 7.5, 9.4, Appendices E, L, M, N, V, W; AS 1628 clauses 4.2, 4.3, 4.4, 4.5, 5.6, Appendices B, C, D; AS 1910 clauses 4.2, 4.3, 4.4, Appendices C, D, E; AS 2419.2 clauses 4.3.2, 4.3.3, 4.3.4, 4.3.5, 4.3.6, Appendices D3, D4, D5, D6, D7; AS/NZS 2638.1 clauses 5.1.2, 5.1.3, 5.1.4, 5.1.5, 5.1.6, 5.1.7, 5.1.8, 5.1.9, 5.1.10, 5.1.11, 5.1.12; AS/NZS 2638.2 clauses 3.2, 3.3, 5.1.1, 5.1.2, 5.1.3, 5.1.4, 5.1.5, 5.1.6, 5.1.7, 5.1.8, 5.1.9, 5.1.10, 5.1.11, 5.1.12, 5.1.13, 5.1.14, 5.1.15; AS/NZS 2845.1; AS 3498 Appendices A, B; AS/NZS 3718 clauses 43.11, .3, 4.5, 4.6.2, 4.8, 4.9, 4.10, 4.11, 4.12, 4.15, Appendices D, F, G, H, I, J, K, L, M, Q; AS 3952 clauses 3.3.1, 3.3.3, 5.1.1, 5.1.2, 5.1.3, 5.4.1, Appendix A; AS 4032.1 clauses 4.3, 4.4, 4.5, 4.6, 4.7, 4.8, 4.9, 4.10, Appendices D, E, F, G, H, I, J; AS 4032.2 clauses 3.2, 3.3.1, 3.3.2, 3.4, 4.4, Appendices C, D, F, G; AS 4794 clauses 5.1.2, 5.1.3, 5.1.4, 5.2.2, 5.2.3, 5.2.4, Appendices D, E; AS 4795 (2006) clauses 5.2.1 Test A, 5.2.2 Test B, 5.2.3 Test C, 5.2.4 Test D, 5.2.5 Test E, 5.2.6 Test F; AS 4796 clauses 4.2, 4.3, 4.4.1, 4.5, 4.7, 4.8, Appendices E, F, G, H, I; AS 5081 clauses 5.2.2, 5.2.3, 5.2.4, 5.2.5, 5.2.6, 5.3,2, 5.3.3, 5.3.4, 5.3.5, 5.3.6, 5.3.7, 5.3.8, 5.3.9; AS/NZS 6400 clause 2.6.3;  WMTS 5200.006 clauses 8.1, 8.3, 9.1, 9.2, 9.3, 9.4, Appendix A; WMTS 5200.012 clauses 9.2, 9.4.1, Appendices B, C; WMTS 5200.030 clauses 9.3, 9.4, Appendix C; WMTS 5200.037.2 clauses 8.1, 9.2, 9.3, 9.4, Appendices B, C, D, F; WMTS 5200.053 clause 9; WMTS 5200.460 clause 9.1; WMTS 5200.467 clauses 8.1, 8.3, 9.1, 9.3.2, 9.4; WMTS 5200.476 clauses 9.1,9.2; WMTS 5200.477 clauses 9.2, 9.3, 9.4, 9.5, Appendices B, C, D; WMTS 5200.481 clauses 9.2, 9.3, 9.4.1, 9.4.2, 9.4.3, 9.5, Appendices B, C; ISO/EN 817 clauses 8.3, 8.4, 8.5, 8.6, 8.7, 9.4, 9.5, 10.2, 10.4, 10.5, 10.6, 10.7, 11.2, 12.1, 12.2, 12.3, 13, Annexes A, B; ISO 5208 clauses 4.8, 4.9, 4.10, 4.11, 4.12

    Water treatment appliances and systems;
    Burst pressure; Endurance; Hydrostatic pressure; Strength of assembly;
    Not applicable;
    AS/NZS 3497 clauses 5.2, 5.3, 5.4; WMTS 5200.103 clauses 9.2, 9.3, 9.4; WMTS 5200.104 clause 9.3; WMTS 5200.105 clause 9.3

  • ISO/IEC 17025 (2005)
    Materials
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    Metallic corrosion evaluation
    Copper and copper alloys;
    Dezincification resistance;
    Classical;
    AS 2345 Appendix C