Address Details:
72 Donaldson Road
ROCKLEA, QLD 4106
AUSTRALIA Map
www.trcalibration.com.au

Contact Details:
Mr Kerri Kirk
+61(07) 37179100

Availability:
Services available to external clients

SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

  • ISO/IEC 17025 (2005) - The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
    Calibration
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    DC and low frequency electrical metrology - Electrical instrument calibrators
    Instrument calibrators;
    AC current;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
     0.07% from 100 μA to 220 μA from 10 Hz to 1 kHz
    0.11% from 100 μA to 220 μA from 1 kHz to 5 kHz
    0.54% from 100 μA to 220 μA from 5 kHz to 10 kHz
    0.07% above 220 μA up to 2.2 mA from 10 Hz to 1 kHz
    0.19% above 220 μA up to 2.2 mA from 1 kHz to 5 kHz
    0.65% above 220 μA up to 2.2 mA from 5 kHz to 10 kHz
    0.07% above 2.2 mA up to 22 mA from 10 Hz to 1 kHz
    0.19% above 2.2 mA up to 22 mA from 1 kHz to 5 kHz
    0.56% above 2.2 mA up to 22 mA from 5 kHz to 10 kHz
    0.08% above 22 mA up to 220 mA from 10 Hz to 1 kHz
    0.2% above 22 mA up to 220 mA from 1 kHz to 5 kHz
    1.1% above 22 mA up to 220 mA from 5 kHz to 10 kHz
    0.05% above 220 mA up to 2.2 A from 10 Hz to 40 Hz
    0.07% above 220 mA up to 2.2 A from 40 Hz to 1 kHz
    0.9% above 220 mA up to 2.2 A from 1 kHz to 5 kHz
    0.12% above 2.2 A up to 10 A from 40 Hz to 1 kHz
    0.43% above 2.2 A up to 10 A from 1 kHz to 10 kHz
    0.21% above 10 A up to 20 A from 40 Hz to 1 kHz
    3.5% above 10 A up to 20 A from 1 kHz to 5 kHz 


    Resistance;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.13% from 500 μΩ to less than 1 Ω
    0.01% from 1 Ω to 5 Ω
    0.005% above 5 Ω to 10 Ω
    0.003% above 10 Ω to 1 MΩ
    0.01% above 1 MΩ to 10 MΩ
    0.07% above 10 MΩ to 1 GΩ


    DC voltage;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.002% + 0.2 μV from 0.01 V up to 0.22 V
    0.001% + 0.2 μV from above 0.22 V up to 2.2 V
    0.001% + 1.3 μV from above 2.2 V up to 11 V
    0.003% + 3 μV from above 11 V up to 22 V
    0.005% + 33 μV from above 22 V up to 220 V
    0.002% + 164 μV from above 220 V up to 1100 V 


    AC voltage;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.07% from 10 mV to 22 mV and from 10 Hz to 20 kHz
    0.08% from 10 mV to 22 mV and from 20 kHz to 50 kHz
    0.24% from 10 mV to 22 mV and from 50 kHz to 100 kHz
    0.35% from 10 mV to 22 mV and from 100 kHz to 300 kHz
    0.05% from 22 mV to 220 mV and from 10 Hz to 50 kHz
    0.1% from 22 mV to 220 mV and from 50 kHz to 100 kHz
    0.34% from 22 mV to 220 mV and from 100 kHz to 300 kHz
    0.05% from 0.22 V to 2.2 V and from 10 Hz to 50 kHz
    0.1% from 0.22 V to 2.2 V and from 50 kHz to 100 kHz
    0.16% from 0.22 V to 2.2 V and from 100 kHz to 300 kHz
    0.05% from 2.2 V to 22 V and from 10 Hz to 50 kHz
    0.1% from 2.2 V to 22 V and from 50 kHz to 100 kHz
    0.22% from 2.2 V to 22 V and from 100 kHz to 300 kHz
    0.03% from 22 V to 220 V and from 10 Hz to 20 kHz
    0.15% from 22 V to 70 V and from 100 kHz to 300 kHz
    0.08% from 22 V to 220 V and from 20 kHz to 50 kHz
    0.3% from 22 V to 220 V and from 50 kHz to 100 kHz
    0.02% from 220 V to 1000 V and from 15 Hz to 40 Hz
    0.03% from 220 V to 1100 V and from 40 Hz to 20 kHz
    0.08% from 220 V to 750 V and from 20 kHz to 50 kHz 


    DC current;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    25 μA/A + 0.9 nA from 10 μA to 100 μA
    25 μA/A + 6 nA above 100 μA to 1 mA
    25 μA/A + 60 nA above 1 mA to 10 mA
    45 μA/A + 0.6 μA above 10 mA to 100 mA
    0.01% above 100 mA to 1 A
    0.02% above 1 A to 2 A
    0.05% above 2 A to 10 A
    0.12% above 10 A to 20 A 
    DC and low frequency electrical metrology - Electrical measurement and test equipment
    Current clamps;
    AC current; DC current;
    Comparison with a reference standard;
    CAPABILITY
    DC Clamp Meters
    with Calibration and Measurement Capability of -
    0.34% from 20 A to 1000 A 
    AC Clamp Meters
    with Calibration and Measurement Capability of -
    0.34% from 20 A up to 1000 A and from 45 Hz to 100 Hz
    1% from 20 A up to 350 A above 100 Hz to 440 Hz 

    Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters;
    Resistance;
    Comparison with a reference standard;
    including megohmmeters up to 1 GΩ and up to 1000 V dc applied voltage
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.13% from 500 μΩ to less than 1 Ω
    0.01% from 1 Ω to 5 Ω
    0.005% above 5 Ω to 10 Ω
    0.003% above 10 Ω to 1 MΩ
    0.01% above 1 MΩ to 10 MΩ
    0.07% above 10 MΩ to 1 GΩ 



    Digital multimeters (DMM); LCR meters;
    Capacitance;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.1% from 10 pF to 100 μF and from 50 Hz to 1 kHz

    Digital multimeters (DMM); Voltmeters;
    AC voltage;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.07% from 10 mV to 22 mV and from 10 Hz to 20 kHz
    0.08% from 10 mV to 22 mV and from 20 kHz to 50 kHz
    0.24% from 10 mV to 22 mV and from 50 kHz to 100 kHz
    0.35% from 10 mV to 22 mV and from 100 kHz to 300 kHz
    0.05% above 22 mV to 220 mV and from 10 Hz to 50 kHz
    0.1% above 22 mV to 220 mV and from 50 kHz to 100 kHz
    0.34% above 22 mV to 220 mV and from 100 kHz to 300 kHz
    0.05% above 0.22 V to 2.2 V and from 10 Hz to 50 kHz
    0.1% above 0.22 V to 2.2 V and from 50 kHz to 100 kHz
    0.16% above 0.22 V to 2.2 V and from 100 kHz to 300 kHz
    0.05% above 2.2 V to 22 V and from 10 Hz to 50 kHz
    0.1% above 2.2 V to 22 V and from 50 kHz to 100 kHz
    0.22% above 2.2 V to 22 V and from 100 kHz to 300 kHz
    0.15% above 22 V to 70 V and from 100 kHz to 300 kHz
    0.03% above 22 V to 220 V and from 10 Hz to 40 Hz
    0.03% above 22 V to 220 V and from 40 Hz to 20 kHz
    0.08% above 22 V to 220 V and from 20 kHz to 50 kHz
    0.3% above 22 V to 220 V and from 50 kHz to 100 kHz
    0.02% above 220 V  to 1000 V and from 15 Hz to 40 Hz
    0.03% above 220 V to 1100 V and from 40 Hz to 20 kHz
    0.08% above 220 V to 750 V and from 20 kHz to 50 kHz 


    DC voltage;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.002% + 0.2 μV from 0.01 to 0.22 V
    0.001% + 0.2 μV above 0.22 V to 2.2 V
    0.001% + 1.3 μV above 2.2 V to 11 V
    0.003% + 3 μV above 11 V to 22 V
    0.005% + 33 μV above 22 V to 220 V
    0.002% + 164 μV above 220 V to 1100 V 

    Ammeters; Digital multimeters (DMM);
    DC current;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    25 μA/A + 0.9 nA from 10 μA to 100 μA
    25 μA/A + 6 nA above 100 μA to 1 mA
    25 μA/A + 60 nA above 1 mA to 10 mA
    45 μA/A + 0.6 μA above 10 mA to 100 mA
    0.01% above 100 mA to 1 A
    0.02% above 1 A to 2 A
    0.05% above 2 A to 10 A
    0.12% above 10 A to 20 A


    AC current;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.07% from 100 μA to 220 μA and from 10 Hz to 1 kHz
    0.11% from 100 μA to 220 μA and from 1 kHz to 5 kHz
    0.54% from 100 μA to 220 μA and from 5 kHz to 10 kHz
    0.07% above 220 μA to 2.2 mA and from 10 Hz to 1 kHz
    0.19% above 220 μA to 2.2 mA and from 1 kHz to 5 kHz
    0.65% above 220 μA to 2.2 mA and from 5 kHz to 10 kHz
    0.07% above 2.2 mA to 22 mA and from 10 Hz to 1 kHz
    0.19% above 2.2 mA to 22 mA and from 1 kHz to 5 kHz
    0.56% above 2.2 mA to 22 mA and from 5 kHz to 10 kHz
    0.08% above 22 mA to 220 mA and from 10 Hz to 1 kHz
    0.2% above 22 mA to 220 mA and from 1 kHz to 5 kHz
    1.1% above 22 mA to 220 mA and from 5 kHz to 10 kHz
    0.05% above 220 mA to 2.2 A and from 10 Hz to 40 Hz
    0.07% above 220 mA to 2.2 A and from 40 Hz to 1 kHz
    0.9% above 220 mA to 2.2 A and from 1 kHz to 5 kHz
    0.12% above 2.2 A to 10 A and from 40 Hz to 1 kHz
    0.43% above 2.2 A to 10 A and from 1 kHz to 10 kHz
    0.21% above 10 A to 20 A and from 40 Hz to 1 kHz
    3.5% above 10 A to 20 A and from 1 kHz to 5 kHz
    DC and low frequency electrical metrology - Electrical standards
    Conductance boxes; Precision resistors; Resistance boxes;
    Resistance;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.13% from 500 μΩ to less than 1 Ω
    0.01% from 1 Ω up to 5 Ω
    0.005% from 5 Ω up to 10 Ω
    0.003% from 10 Ω up to 1 MΩ
    0.01% from 1 MΩ up to 10 MΩ
    0.07% from 10 MΩ up to 1 GΩ
    DC and low frequency electrical metrology - High-voltage/high-current standards and equipment
    High voltage test sets;
    Voltage;
    Comparison with a reference standard;




    CAPABILITY
    with Calibration and Measurement Capability of -
    0.2% from 1000 V up to 90 kV DC
    0.4% from 1000 V up to 70 kV AC at 50 Hz 


    Dimensional metrology - Engineering equipment and precision instruments
    Electronic calipers; Vernier calipers;
    Length measurements;
    Comparison with a reference standard;
    for compliance with AS 1984, BS 887 and JIS B7507 


    CAPABILITY
    with Calibration and Measurement Capability of -
    (10 + 0.01L) μm for indication errors where L is the scale value in mm up to 300 mm



    Dial gauges;
    Length measurements;
    Comparison with a reference standard;
    For compliance with AS 2103, BS 907 and BS 2795 and JIS B7503 
    CAPABILITY
    with Calibration and Measurement Capability of -
    1.2 μm for linear measurements up to 10 mm;
    2.5 μm for linear measurements from 10 up to 25 mm;
    3.5 μm for linear measurements from 25 up to 100 mm



    External micrometers;
    Length measurements;
    Comparison with a reference standard;
    for compliance with AS 2102, BS 870 and JIS B7502 
    CAPABILITY
    with Calibration and Measurement Capability of -
    (1 + 0.01L) μm for indication errors where L is the length in mm up to 300 mm


    Pressure metrology - Pressure and vacuum measuring equipment
    Digital pressure gauges; Mechanical pressure gauges; Pressure transducers; Vacuum gauges;
    Gauge pressure; High vacuum;
    Comparison with dead weight tester; Comparison with reference instrument;
    AS 1349
    .
    Electrical transducers with dc voltage, dc current or resistance outputs
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.035% or 5 Pa (whichever is greater) from -100 kPa to 2 MPa;
    0.06% from 2 to 5.5 MPa;
    0.09% from 5.5 to 14 MPa;
    0.05% from 14 to 70 MPa;
    Time and frequency metrology - Frequency, time and waveform measuring equipment
    Counters; Frequency meters;
    Frequency;
    Measurement against reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    1 in 107 from 100 mHz to 500 MHz

    Tachometers;
    Rotational speed;
    Comparison with a reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.013 rpm from 1 rpm to 99 rpm
    0.13 rpm from 100 rpm to 999 rpm
    1.3 rpm from 1 000 rpm to 99 999 rpm 

    Time interval meters;
    Time interval;
    Measurement against reference standard;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.02% from 50 μs to 10 s
    Torque - Torque measuring and testing equipment
    Torque transducers;
    Torque;
    Gravimetric measurement with reference beam;
    BS 7882
    CAPABILITY
    With a Calibration and Measurement Capability of -
    0.3% from 0.1 to 25 Nm
    0.2% from above 25 to 3000 Nm
    Torque - Torque measuring and testing equipment
    Torque wrenches;
    Torque;
    Comparison with a reference standard;
    including on site calibrations



    CAPABILITY
    Including on-site calibrations
    With a Calibration and Measurement Capability of -
    0.9% of indicated value from 0.1 Nm to 1500 Nm;
    Vibration metrology - Vibration equipment
    Accelerometers;
    Acceleration sensitivity; Frequency;
    Comparison measurement against reference transducer; Direct measurement by electrical input;
    ISO 16063-21 


    CAPABILITY
    Accelerometers of a mass up to 270 grams in the acceleration range from 9.8m/sto 392 m/s from 5 Hz to 20 kHz with a sensitivity from 3.0 pc/g to 100 pc/g (0.3 pC/ms-2 to 10.2 pC/ms-2), or 10 mV/g to 100 mV/g (1.0 mV/ms-2  to  10.2 mV/ms-2)
    with Calibration and Measurement Capability of -
    1.8% of reading over the frequency range 5 to 9 Hz
    1.3% of reading over the frequency range 10 to 99 Hz
    1% of reading at the frequency range 100 Hz
    1.1% of reading over the frequency range 101 to 920 Hz
    1.4% of reading over the frequency range 921 to 5000 Hz
    2.0% of reading over the frequency range 5001 to 10 000 Hz
    2.4% of reading over the frequency range 10 001 to 15 000 Hz
    3.4% of reading over the frequency range 15 001 to 20 000 Hz



    Velocity transducers;
    Frequency; Velocity sensitivity;
    Comparison measurement against reference transducer; Direct measurement by electrical input;
    CAPABILITY
    Velocity transducers of a mass up to 270 grams, in the velocity range from 5 mm/s to 394 mm/s from 5 Hz to 10 kHz, with a sensitivity from 10 mV/in/s to 100 mV/in/s (0.394 V/ms-1 to 3.94 V/ms-1)
    with Calibration and Measurement Capability of -
    2.4% of reading over the frequency range 5 to 9 Hz
    1.6% of reading over the frequency range 10 to 99 Hz
    1.3% of reading over the frequency range 100 and 160 Hz
    2.0% of reading over the frequency range 101 to 1000 Hz
    2.0% of reading over the frequency range 1001 to 5000 Hz
    2.5% of reading over the frequency range 5001 to 10 000 Hz