Back to Search Results


Address Details:
176 Harrick Road
KEILOR PARK, VIC 3042
AUSTRALIA Map
www.emctech.com.au

Contact Details:
Mr A Whiteford
+61(03) 93651000

Availability:
Services available to external clients

SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

  • ISO/IEC 17025 (2005)
    Manufactured Goods
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    Assessment of emissions and immunity - EMC emission standards
    Maritime navigation equipment;
    Conducted emissions; Conducted interference; Radiated interference;
    Not applicable;
    EN 60945
    Excluding measurements below 2 kHz

    Vehicles, boats and internal combustion engine driven equipment;
    Conducted interference; Radiated interference;
    Not applicable;
    AS/NZS CISPR 25; CISPR 25; EN 55025;
    AS/NZS CISPR 12; CISPR 12; EN 55012;
    ISO 7637-2; ISO 7637-3

    Testing on components only



    Power leads;
    Conducted interference; Radiated interference;
    Not applicable;
    MIL-STD-461 D/E/F: CE101 (30 Hz to 10 kHz);
    MIL-STD-461 D/E/F: CE102 (10 kHz to 10 MHz)

    Telecommunication network equipment;
    Conducted emissions; Conducted interference; Radiated interference;
    Not applicable;
    ETSI EN 300 386

    Medical electrical equipment;
    Conducted interference; Radiated interference;
    Not applicable;
    AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803;
    AS/NZS 3200.1.2; IEC 60601-1-2; EN 60601-1-2

    Aerospace and military grade equipment;
    Radiated emissions;
    Not applicable;
    MIL-STD-461 B/C: RE01;
    MIL-STD-461 B/C: RE02;
    MIL-STD-461 D/E/F: RE101;
    MIL-STD-461 D/E/F: RE102;
    MIL-STD-461 B/C: RE01 - 30 Hz to 50 kHz
    MIL-STD-461 B/C: RE02 - 14 kHz to 10 GHz
    MIL-STD-461 D/E/F: RE101 - 30 Hz to 100 kHz
    MIL-STD-461 D/E/F: RE102 - 10 kHz to 18 GHz 


    Conducted emissions; Conducted interference; Discontinuous disturbances; Disturbance power; Radiated interference;
    Not applicable;
    MIL-STD-461 B/C: CE01 - 0 to 15 kHz;
    MIL-STD-461 B/C: CE03 - 0.015 MHz to 50 MHz;

    Electrical equipment for measurement, control and laboratory use;
    Conducted emissions; Conducted interference; Radiated interference;
    Not applicable;
    AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803;
    IEC 61326-1; EN 61326-1
    Excluding measurements below 2 kHz

    Information technology equipment;
    Conducted emissions; Conducted interference; Conducted telecommunications port emissions; Radiated interference;
    AMN and voltage probe; ISN and current clamp;
    Excluding capacitive voltage probe tests for telecommunications ports AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; VCCI; CNS 13438; EN 55022

    Electrical lighting and similar equipment;
    Conducted emissions; Conducted interference; Radiated emissions; Radiated interference;
    Not applicable;
    AS/NZS CISPR 15; CISPR 15; EN 55015 

    Sound and television broadcast receivers and associated equipment;
    Conducted interference; Disturbance power; Radiated interference;
    Not applicable;
    AS/NZS CISPR 13; CISPR 13; EN 55013; CNS 13439 

    Electrical and electronic products; Power tools - Electric;
    Conducted emissions; Conducted interference; Discontinuous disturbances; Disturbance power; Radiated interference;
    Not applicable;
    AS/NZS CISPR 14.1; CISPR 14-1; EN 55014-1; CNS 13783-1;
    AS/NZS CISPR 32 ED 2.0; CISPR 32 ED 2.0; EN 55032;
    AS/NZS 4251.1; AS/NZS 61000.6.3; IEC 61000-6-3; EN 61000-6-3
    FCC part 18 requirements and MP-5 for intentional emitters up to 18 GHz; 
    FCC part 15 requirements; ANSI C63.4:2014;  ANSI C63.10:2013;  KDB publications and ISED (formerly Industry Canada) ICES-003;
    Unintentional radiators described in FCC part 15, subpart B using ANSI C63.4-2014; 
    Intentional radiators described in FCC part 15, subpart C using ANSI C63.10-2013; 
    Intentional  radiators described in FCC part 15, subpart E for U-NII devices without DFS using ANSI C63.10:2013; 
    FCC KDB guidelines: KDB 789033 D02; KDB 558074 D01;
    RSS-210;
    RSS-247;
    RSS-GEN


    Radiated measurements performed in the 10 metre iOATS Semi Anechoic Chamber Room 12 - Test Site 1 and in the 3 metre iOATS Semi Anechoic Chamber Room 13 - Test Site 2


    Machine tools;
    Conducted emissions; Conducted interference; Discontinuous disturbances; Mains harmonics and flicker; Radiated emissions; Radiated interference;
    Not applicable;
    AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803; 
    AS/NZS 61000.6.4; IEC 61000-6-4; EN 61000-6-4;
    IEC 61000-3-2; IEC 61000-3-3

    Railway vehicles and equipment including railway signalling and telecommunications equipment;
    Conducted interference; Radiated interference;
    Not applicable;
    EN 50121-2; EN 50121-3-1; EN 50121-3-2; EN 50121-4; EN 50121-5

    Radio equipment;
    Conducted emissions; Conducted interference; Radiated interference;
    Not applicable;
    ETSI EN 301 489-1  

    Shielded enclosures;
    Attenuation performance;
    Not applicable;
    MIL-STD-285 Rev. 1.8

    Airborne equipment;
    Conducted interference; Radiated interference;
    Not applicable;
    RTCA DO160 F/G section 21 
    Conducted RF emissions 150 kHz to 150 MHz 
    Assessment of emissions and immunity - EMC immunity standards
    Low voltage switchgear and control equipment;
    Common mode low frequency; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    EN 60947;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Telecommunication network equipment;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    ETSI EN 300 386;
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Electricity meters and associated transformers;
    Electrical fast transient; Radiated radio-frequency; Surge immunity;
    Not applicable;
    NSC publication for Pattern Approval and Initial verification of electricity meters and associated transformers

    Medical electrical equipment;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    AS/NZS 3200.1.2; IEC 60601-1-2; EN 60601-1-2;
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Aerospace and military grade equipment;
    Conducted disturbance; Radiated radio-frequency;
    Bulk cable injection; Damped sinusoidal transients; Impulse excitation; Magnetic field;
    MIL-STD-461 B/C: RS01, RS02, RS03; 
    MIL-STD-461 D/E/F: RS101, RS103 
    MIL-STD-461 B/C: CS01, CS02 (except broadband susceptibility to Notice 3), CS06; 
    MIL-STD-461 D/E/F: CS101, CS114, CS115, CS116; 
    MIL-STD-461 B/C RS01: 30 Hz to 50 kHz;
    MIL-STD-461 B/C RS03: 14 kHz to 18 GHz ; 
    MIL-STD-461 D/E/F RS101: 30 Hz to 100 kHz; 
    MIL-STD-461 D/E/F RS103: 2 MHz to 18 GHz;
    MIL-STD-461 B/C CS01: 30 Hz to 50 kHz; 
    MIL-STD-461 B/C CS02: 0.5 MHz to 400 MHz; 
    MIL-STD-461 D/E/F CS101: 30 Hz to 150 kHz; 
    MIL-STD-461 D/E/F CS114: 10 kHz to 400 MHz;

    Electrical equipment for measurement, control and laboratory use;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    IEC 61326-1; EN 61326-1;
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Information technology equipment;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    AS/NZS CISPR 24; CISPR 24; EN 55024;
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Electrical lighting and similar equipment;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    EN 61547;
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Electrical and electronic products; Power tools - Electric;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    AS/NZS CISPR 14.2; CISPR 14-2; EN 55014-2;
    AS/NZS 61000.6.1; IEC 61000-6-1; EN 6000-6-1;
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Machine tools;
    Conducted disturbance; Electrical fast transient; Electrostatic discharge; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    AS/NZS 61000.6.2; IEC 61000-6-2; EN 61000-6-2; 
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Railway vehicles and equipment including railway signalling and telecommunications equipment;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    EN 50121-3-2; EN 50121-4; EN 51021-5
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Radio equipment;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    ETSI EN 301 489-1;
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Components of fire, intruder and social alarm systems;
    Common mode low frequency; Conducted disturbance; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Ring wave; Surge immunity; Voltage short dips and interruptions;
    Not applicable;
    EN 50130-4;
    ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2; ISO 10605; SAE J1113-13;
    AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; ISO 11452-4;
    IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4;
    AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5;
    AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6;
    AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8;
    IEC 61000-4-9; EN 61000-4-9;
    IEC 61000-4-10; EN 61000-4-10;
    AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11
    IEC 61000-4-12;
    AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; 
    AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16;
     IEC 61000-4-18; EN 61000-4-18

    Airborne equipment;
    Conducted disturbance; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Voltage spikes;
    Not applicable;
    RTCA DO160 F/G Sections 15, 17, 18, 19, 20, 25;
    Assessment of emissions and immunity - Non-ionising radiation strength and hazard assessment
    Hand held and wireless communication devices;
    Specific absorption rate (SAR);
    Not applicable;
    ACMA Radiocommunications (Electromagnetic Radiation - Human exposure) Standard;
    ARPANSA Radiation Protection Standard (RPS No.3);
    NZS 2772.1;
    EN 50566:2013; EN 50360:2001; EN 62311:2008; EN 62209-1:2006; EN 62209-2:2010; 
    IEEE 1528; 
    FCC - guidelines for human exposure to RF electromagnetic field:1997;
    FCC KDB guidelines: 
    KDB 865664 D01; KDB 865664 D02; KDB 447498; KDB 447498 D02; KDB 447498; KDB 643646 D01; KDB 248227 D01; KDB 941225 D01; KDB 941225 D05; KDB 941225 D05A; KDB 941225 D06; KDB 941225 D07; KDB 616217 D04; KDB 648474 D04; KDB 648474 D03; KDB 615223 D01;
    Canadian Standard RSS-102 (SAR) including SPR-002 (NS)
    30 MHz - 6 GHz; 300 MHz - 3 GHz; 300 MHz To 3 GHz; 30 MHz To 6 GHz

    Antennas; Electricity grid installations; High voltage transformer equipment; Microwave ovens;
    Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields;
    Not applicable;
    AS/NZS 2772.2 and EMC Technologies in-house TP EME ARPANSA for compliance with ARPANSA (RPS No.3) and NZS 2772.1;
    EN 62311:2008;
    EN 62233;
    Canadian standard RSS-102 (RF) including SPR-002 (NS)
    Broadband measurements of E-fields in the range 100 kHz to 45.5 GHz;
    Broadband measurements of H-fields in the range 100 kHz to 1 GHz;
    Narrowband measurements of E-fields in the range 9 kHz to 40 GHz;
    Narrowband measurements of H-fields in the range 9 kHz to 300 MHz
    Testing of gaming machines and gaming systems
    Interactive gaming; Land-based gaming; Wide area gaming systems;
    Gaming equipment hardware testing; Gaming platform evaluation;
    Electrical fast transient; Electrostatic interference; Voltage short dips and interruptions;
    Australian Gaming Standard