SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.


  • ISO/IEC 17025 (2005) - The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
    Calibration
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    DC and low frequency electrical metrology - Electrical instrument calibrators
    Instrument calibrators;
    Resistance;
    Comparison with a reference standard;
    1 mΩ to 1 TΩ

    CAPABILITY
    with Calibration and Measurement Capability of - 

    10 μΩ/Ω from 1 mΩ to 100 mΩ
    4 μΩ/Ω from 100 mΩ to 10 Ω
    1.5 μΩ/Ω from 10 Ω to 10 kΩ
    2.5 μΩ/Ω from 10 kΩ to 100 kΩ
    4 μΩ/Ω from 100 kΩ to 1 MΩ
    40 μΩ/Ω from 1 MΩ to 100 MΩ
    0.17% from 100 MΩ to 10 GΩ
    0.27% from 10 GΩ to 1 TΩ



    AC voltage;
    Comparison with a reference standard;
    2 mV at 20 Hz, 40 Hz to 50 kHz, 100 kHz, 200 kHz, 300 kHz and 500 kHz
    10 mV to 30 mV at 10 Hz, 20 Hz, 40 Hz to 50 kHz, 100 kHz, 200 kHz, 300 kHz, 500 kHz, 1 MHz, 10 Hz, 20 Hz, 40 Hz to 100 kHz, 200 kHz, 300 kHz, 500kHz and 1 MHz
    300 mV to 200 V at 10 Hz
    30 mV to 300 V from 20 Hz to 50 kHz
    30 mV to 700m V from 100 kHz to 300 kHz, 500 kHz and 1 MHz
    700 mV to 2.2 V at 100 kHz, 200 kHz, 300 kHz and 500 kHz, 1 MHz
    2.2 V to 7 V at 100 kHz, 200 kHz, 300 kHz and from 500 kHz to 1 MHz
    7 V to 300 V at 100 kHz
    7 V to 100 V at 200 kHz
     7 V to 60 V from 300 kHz to 500 kHz
    7 V to 22 V at 1 MHz
    300 V to 1000 V at 40 Hz to 50 kHz and 100 kHz
    0.2 V to 3 V from 1 MHz to 30 MHz

    CAPABILITY
    with Calibration and Measurement Capability of - 

    275 μV/V at 2 mV at 20 Hz
    250 μV/V at 2 mV from 40 Hz to 50 kHz
    260 μV/V at 2 mV at 100 kHz
    290 μV/V at 2 mV at 200 kHz
    320 μV/V at 2 mV at 300 kHz
    520 μV/V at 2 mV at 500 kHz
    140 μV/V from 10 mV to 30 mV at 10 Hz
    100 μV/V from 10 mV to 30 mV at 20 Hz
    80 μV/V from 10 mV to 30 mV from 40 Hz to 50 kHz
    90 μV/V from 10 mV to 30 mV at 100 kHz
    130 μV/V from 10 mV to 30 mV at 200 kHz
    165 μV/V from 10 mV to 30 mV at 300 kHz
    350 μV/V from 10 mV to 30 mV at 500 kHz
    1200 μV/V from 10 mV to 30 mV at 1 MHz
    55 μV/V from 30 mV to 300 mV at 10 Hz
    45 μV/V from 30 mV to 300 mV at 20 Hz
    55 μV/V from 30 mV to 300 mV from 40 Hz to 100 kHz
    95 μV/V from 30 mV to 300 mV at 200 kHz
    150 μV/V from 30 mV to 300 mV at 300 kHz
    350 μV/V from 30 mV to 300 mV at 500kHz
    1330 μV/V from 30 mV to 300 mV at 1 MHz
    55 μV/V from 300 mV to 200 V at 10 Hz
    50 μV/V from 30 mV to 300 V from 20 Hz to 50 kHz
    45 μV/V from 30 mV to 700m V from 100 kHz to 300 kHz
    65 μV/V from 30 mV to 700 mV at 500 kHz
    100 μV/V from 30 mV to 700 mV at 1 MHz
    60 μV/V from 700 mV to 2.2 V at 100 kHz
    290 μV/V from 700 mV to 2.2 V at 200 kHz
    350 μV/V from 700 mV to 2.2 V at 300 kHz
    1800 μV/V from 700 mV to 2.2 V at 500 kHz
    5300 μV/V from 700 mV to 2.2 V at 1 MHz
    50 μV/V from 2.2 V to 7 V at 100 kHz
    70 μV/V from 2.2 V to 7 V at 200 kHz
    75 μV/V from 2.2 V to 7 V at 300 kHz
    700 μV/V from 2.2 V to 7 V from 500 kHz to 1 MHz
    50 μV/V from 7 V to 300 V at 100 kHz
    65 μV/V from 7 V to 100 V at 200 kHz
    70 μV/V from 7 V to 60 V from 300 kHz to 500 kHz
    75 μV/V from 7 V to 22 V at 1 MHz
    50 μV/V from 300 V to 1000 V at 40 Hz to 50 kHz
    75 μV/V from 300 V to 1000 V at 100 kHz
    700 μV/V from 0.2 V to 3 V from 1 MHz to less than 10 MHz
    1000 μV/V from 0.2 V to 3 V from 10 MHz to less than 30 MHz
    1900 μV/V from 0.2 V to 3 V at 30 MHz



    DC current;
    Comparison with a reference standard;
    from 0 A to 100 A 


    CAPABILITY
    with Calibration and Measurement Capability of - 

    150 pA up to 10 μA
    15 μA/A from 10 μA to 20 A
    65 μA/A from 20 A to 100 A 



    AC current;
    Comparison with a reference standard;
    100 μA to 200 μA from 10 Hz to 1 kHz, 5 kHz and 10 kHz
    200 μA to 2 mA from 10 Hz to to 1 kHz, 5 kHz and 10 kHz
    2 mA to 20 A from 10 Hz to to 1 kHz, 5 kHz and 10 kHz
    10 mA to 300 mA at 30 kHz
    20 A to 100 A from 10 Hz to 1 kHz

    CAPABILITY
    with Calibration and Measurement Capability of - 

    290 μA/A from 100 μA to 200 μA from 10 Hz to <1 kHz
    310 μA/A from 100 μA to 200 μA at 1 kHz
    335 μA/A from 100 μA to 200 μA at 5 kHz
    380 μA/A from 100 μA to 200 μA at 10 kHz
    285 μA/A from 200 μA to 2 mA from 10 Hz to <1 kHz
    290 μA/A from 200 μA to 2 mA at 1 kHz
    320 μA/A from 200 μA to 2 mA at 5 kHz
    355 μA/A from 200 μA to 2 mA at 10 kHz
    70 μA/A from 2 mA to 20 A from 10 Hz to 1 kHz
    190 μA/A from 2 mA to 20 A at 5 kHz
    580 μA/A from 2 mA to 20 A at 10 kHz
    580 μA/A from 10 mA to 300 mA at 30 kHz
    170 μA/A from 20 A to 100 A from 10 Hz to 1 kHz



    DC voltage;
    Comparison with a reference standard;
    from 0 V to 10000 V

    CAPABILITY
    with Calibration and Measurement Capability of - 

    0.4 μV up to 100 mV
    2.5 μV/V at 1 V and 10 V
    4.0 μV/V from 100 mV to 100 V
    8.5 μV/V from 100 V to 1100 V
    0.2% from 1100 V to 10000 V

    DC and low frequency electrical metrology - Electrical measurement and test equipment
    Capacitance meters; Data recorders; Digital multimeters (DMM); Galvano meters and null detectors; Insulation resistance test equipment; Ohm meters; Power analysers; Power supplies; Residual current circuit breaker testers; Voltmeters; Watt meters;
    DC voltage;
    Comparison with a reference standard;
    from 1 mV to 10 kV

    CAPABILITY
    with Calibration and Measurement Capability of - 

    2.4 μV/V at 1.018 V and 10 V
    3.7 μV/V + 0.1 μ V from 1 mV to 100 V;
    6.4 μV/V from 100 to 1100 V;
    2500 μV/V from 1.1 kV to 10 kV


    LCR meters;
    Capacitance; Inductance; Resistance;
    Comparison with a reference standard;
    D.C. Resistance from 1 Ω to 2 MΩ
    Capacitance from 1 pF to 110 μF and 50 Hz to 1 kHz
    Inductance 100 μH to 100 mH and 10 H and at 1 kHz


    CAPABILITY
    with Calibration and Measurement Capability of - 

    D.C. Resistance
    0.035% at 1 Ω
    0.02% from 1 Ω to 1 MΩ
    0.035% from 1 MΩ to 2 MΩ

    Capacitance 50 Hz to 1 kHz
    0.03% + 0.1 pF from 1 pF to 1 μF
    0.045% from 1 μF to 110 μF

    Inductance at 1 kHz

    0.05% from 100 μH to 100 mH
    0.13% at 10 H 



    Galvano meters and null detectors;
    AC voltage; DC voltage;
    Comparison with a reference standard;
    from 0 V to 1 mV


    CAPABILITY
    with Calibration and Measurement Capability of - 

    0.1% + 0.1 μV from 0 V to 1 mV


    Current clamps; Data recorders; Power analysers; Power supplies; Watt meters;
    AC current;
    Comparison with a reference standard;
    Clamp Meters at DC, 50 Hz to 1 kHz from 1 mA to 5000 A


    CAPABILITY
    with Calibration and Measurement Capability of - 

    0.2% from 1 mA to 1000 A, 50 Hz to 1 kH
    0.64% from 1000 A to 5000 A, 50 Hz to 400 Hz


    Appliance testers; Capacitance meters; Data recorders; Digital multimeters (DMM); Galvano meters and null detectors; Insulation resistance test equipment; LCR meters; Ohm meters; Phase angle meters; Power analysers; Power supplies; Voltmeters; Watt meters;
    AC voltage;
    Comparison with a reference standard;
    2 mV from 20 Hz to 50 kHz, at 100 kHz, 200 kHz to 500 kHz
    10 mV to 30 mV at 10 Hz, 20 Hz, 40 Hz to 50 kHz, 100 kHz to 300 kHz, 500 kHz, 1 MHz
    30 mV to 300 mV at 10 Hz, 20 Hz to 100 kHz, 200 kHz, 300 kHz, 500 kHz, 1 MHz
    300 mV to 200 V at 10 Hz
    30 mV to 300 V from 20 Hz to 50 kHz
    30 mV to 700 mV from 100 kHz to 500 kHz and at 1 MHz
    700 mV to 2.2 V from 100 kHz to 200 kHz, at 300 kHz, 500 kHz, 1 MHz
    2.2 V to 7 V from 100 kHz to 300 kHz, at 500 kHz, 1 MHz
    7 V to 300 V at 100 kHz
    7 V to 100 V at 200 kHz
    7 V to 60 V at 300 kHz
    7 V to 30 V at 500 kHz
    7 V to 22 V at 1 MHz
    300 V to 1000 V from 40 Hz to 50 kHz and at 100 kHz 


    CAPABILITY
    with Calibration and Measurement Capability of -

    310 μV/V at 2 mV from 20 Hz to 50 kHz
    300 μV/V at 2 mV at 100 kHz
    450 μV/V at 2 mV from 200 kHz to 500 kHz
    165 μV/V from 10 mV to 30 mV at 10 Hz
    140 μV/V from 10 mV to 30 mV at 20 Hz
    125 μV/V from 10 mV to 30 mV from 40 Hz to 50 kHz
    130 μV/V from 10 mV to 30 mV from 100 kHz to 300 kHz
    140 μV/V from 10 mV to 30 mV at 300 kHz
    160 μV/V from 10 mV to 30 mV at 500 kHz
    200 μV/V from 10 mV to 30 mV at 1 MHz
    75 μV/V from 30 mV to 300 mV at 10 Hz
    70 μV/V from 30 mV to 300 mV from 20 Hz to 100 kHz
    75 μV/V from 30 mV to 300 mV at 200 kHz
    85 μV/V from 30 mV to 300 mV at 300 kHz
    100 μV/V from 30 mV to 300 mV at 500 kHz
    205 μV/V from 30 mV to 300 mV at 1 MHz
    55 μV/V from 300 mV to 200 V at 10 Hz
    50 μV/V from 30 mV to 300 V from 20 Hz to 50 kHz
    50 μV/V from 30 mV to 700 mV from 100 kHz to 500 kHz
    110 μV/V from 30 mV to 700 mV at 1 MHz
    45 μV/V from 700 mV to 2.2 V from 100 kHz to 200 kHz
    50 μV/V from 700 mV to 2.2 V at 300 kHz
    100 μV/V from 700 mV to 2.2 V at 500 kHz
    110 μV/V from 700 mV to 2.2 V at 1 MHz
    50 μV/V from 2.2 V to 7 V from 100 kHz to 300 kHz
    100 μV/V from 2.2 V to 7 V at 500 kHz
    110 μV/V from 2.2 V to 7 V at 1 MHz
    50 μV/V from 7 V to 300 V at 100 kHz
    50 μV/V from 7 V to 100 V at 200 kHz
    70 μV/V from 7 V to 60 V at 300 kHz
    120 μV/V from 7 V to 30 V at 500 kHz
    120 μV/V from 7 V to 22 V at 1 MHz
    50 μV/V from 300 V to 1000 V from 40 Hz to 50 kHz
    75 μV/V from 300 V to 1000 V at 100 kHz 

    Data recorders; Power analysers; Power supplies; Watt meters;
    Apparent power;
    Comparison with a reference standard;
    from 0.1 V up to 1000 V 

    from 0.001 A to 20 A on DC 

    50 Hz at unity power factor

    CAPABILITY

    with Calibration and Measurement Capability of - 

    0.1% from 0.1 V up to 1000 V
    from 0.001 A to 20 A on DC
    50 Hz at unity power factor

    Data recorders; Ohm meters;
    Resistance;
    Comparison with a reference standard;
    Including megohmmeters up to 1 TΩ and up to 5 000 V dc applied voltage

    CAPABILITY

    with Calibration and Measurement Capability of - 

    100 μΩ/Ω from 10 μΩ to 1 mΩ
    10 μΩ/Ω from 1 to 100 mΩ
    3 μΩ/Ω from 100 mΩ to 1 Ω
    1 μΩ/Ω from 1 Ω to 10 kΩ
    2 μΩ/Ω from 10 to 100 kΩ
    3 μΩ/Ω from 100 kΩ to 1 MΩ
    50 μΩ/Ω from 1 to 100 MΩ
    0.2% from 100 MΩ to 10 GΩ
    0.3% from 10 GΩ to 1 TΩ


    Ammeters; Appliance testers; Capacitance meters; Current clamps; Data recorders; Digital multimeters (DMM); Galvano meters and null detectors; Insulation resistance test equipment; LCR meters; Ohm meters; Phase angle meters; Power analysers; Power supplies; RCD testers; Residual current circuit breaker testers; Watt meters;
    AC current;
    Comparison with a reference standard;
    100 μA to 20 A from 10 Hz to 1 kHz, at 5 kHz and 10 kHz
    10 mA to 300 mA at 30 kHz

    CAPABILITY
    with Calibration and Measurement Capability of - 

    165 μA/A from 100 μA to 200 μA from 10 Hz to <1 kHz
    380 μA/A from 100 μA to 200 μA at 1 kHz
    750 μA/A from 100 μA to 200 μA at 5 kHz
    1000 μA/A from 100 μA to 200 μA at 10 kHz
    185 μA/A from 200 μA to 2 mA from 10 Hz to <1 kHz
    165 μA/A from 200 μA to 2 mA at 1 kHz
    425 μA/A from 200 μA to 2 mA at 5 kHz
    750 μA/A from 200 μA to 2 mA at 10 kHz
    90 μA/A from 2 mA to 20 A from 10 Hz to <1 kHz
    120 μA/A from 2 mA to 20 A at 1 kHz
    450 μA/A from 2 mA to 20 A at 5 kHz
    940 μA/A from 2 mA to 20 A at 10 kHz
    2600 μA/A from 10 mA to 300 mA at 30 kHz


    Ammeters; Power supplies; Watt meters;
    DC current;
    Comparison with a reference standard;
    from 0 A to 200 A

    CAPABILITY
    with Calibration and Measurement Capability of - 

    4% + 0.1 fA up to 20 pA
    1.5% from 20 pA to 200 pA
    5000 μA/A from 200 pA to 20 nA
    2000 μA/A from 20 nA to 10 μA
    14 μA/A from 10 μA to 1 A
    23 μA/A from 1 A to 10 A
    45 μA/A from 10 to 100 A
    200 μA/A from 100 to 200 A

    DC and low frequency electrical metrology - Electrical standards
    Voltage standards - Standard cells;
    Voltage; Voltage AC-DC difference; Voltage ratio;
    Comparison with a reference standard;
    at 1.018 V and 1.019 V 
    CAPABILITY
    with Calibration and Measurement Capability of - 
    1.5 μV at 1.018 V and 1.019 V


    Current shunts;
    Current;
    Comparison with a reference standard;
    DC shunts from 10 μA to 100 A
    AC shunts from 100 μA to 20 A
    CAPABILITY
    with Calibration and Measurement Capability of - 
    DC shunts
    5 μA/A from 10 μA to 100 mA
    9 μA/A from 100 mA to 1 A
    20 μA/A from 1 A to 10 A
    30 μA/A from 10 A to 100 A

    AC shunts 
    From 100 μA to 20 A:
    60 μA/A at 57 Hz
    110 μA/A at 1 kHz
    720 μA/A at 5 kHz and 10 kHz


    Voltage standards - E.M.F. reference devices;
    Voltage; Voltage AC-DC difference; Voltage ratio;
    Comparison with a reference standard;
    at 1.0, 1.018 and 10 V


    CAPABILITY
    with Calibration and Measurement Capability of - 

    1.5 μV/V at 1.0, 1.018 and 10 V


    Conductance boxes; Precision resistors; Resistance boxes;
    Resistance;
    Comparison with a reference standard;
    10 μΩ to 1 TΩ


    CAPABILITY
    with Calibration and Measurement Capability of - 
    100 μΩ/Ω from 10 μΩ to 1 mΩ
    10 μΩ/Ω from 1 to 100 mΩ
    3 μΩ/Ω from 100 mΩ to 1 Ω
    1 μΩ/Ω from 1 Ω to 10 kΩ
    2 μΩ/Ω from 10 to 100 kΩ
    3 μΩ/Ω from 100 kΩ to 1 MΩ
    50 μΩ/Ω from 1 to 100 MΩ
    0.2% from 100 MΩ to 10 GΩ
    0.3% from 10 GΩ to 1 TΩ

    Potential dividers; Voltage ratio boxes;
    Voltage ratio;
    Comparison with a reference standard;
    Volt ratio boxes with fixed ratios
    with applied voltages up to 1100 V
    of input up to 1100 V
    Variable ratio potential dividers from 10⁻⁷ to 1.1
    with applied voltages up to 1100 V

    CAPABILITY
    with Calibration and Measurement Capability of - 

    Volt ratio boxes
    2 μV/V of input up to 500 V
    4 μV/V of input from 500 to 1100 V


    Variable ratio potential dividers
    2 μV/V of input up to 500 V
    4 μV/V of input from 500 to 1100 V


    AC/DC transfer instruments;
    Current; Voltage;
    Comparison with a reference standard;
    10 mV to 600 mV at 10 Hz;
    2 mV at 20 to 30 Hz;
    10 mV to 600 mV and 20 to 30 Hz;
    2 mV to 600 mV and 40 Hz to 50 kHz;
    2 mV to 10 mV at 100 kHz;
    10 mV to 600 mV and 100 kHz to 200 kHz;
    2 mV to 10 mV at 200 kHz;
    2 mV at 300 kHz;
    2 mV to 600 mV and 300 to 500 kHz;
    2 mV at 500 kHz;
    2 mV to 600 mV at 1 MHz;
    0.6 V to 1000 V at 10 Hz;
    0.6 V to 1000 V from 20 to 40 Hz;
    0.6 V to 400 V and 50 Hz to 10 kHz;
    0.6 V to 60 V at 20 kHz;
    400 V to 1000 V at 50 Hz;
    60 V to 400 V at 20 kHz;
    400 V to 1000 V and 400 Hz to 20 kHz;
    0.6 V to 1000 V at 50 kHz;
    0.6 V to 1000 V at 100 kHz;
    0.6 V to 60 V and 200 to 500 kHz;
    0.6 V to 20 V and 500 kHz to 1 MHz;
    0.2 V to 3 V at 3 MHz;
    0.2 V to 3 V at 10 MHz;
    0.2 V to 3 V at 30 MHz;
    0.2 V to 3 V at 50 MHz;
    0.27 V at 70 MHz;
    0.2 V  to 3 V at 100 MHz;

    100 μA to 20 A at 57 Hz
    100 μA to 20 A and 100 Hz to 1 kHz
    100 μA to 20 A and 1 kHz to 10 kHz
    10 mA to 300 mA at 30 kHz
    CAPABILITY
    with Calibration and Measurement Capability of - 

    820 μV/V at 10 mV at 10 Hz;
    310 μV/V from 10 mV to 600 mV at 10 Hz;
    715 μV/V at 2 mV from 20 to 30 Hz;
    620 μV/V from 10 mV to 300 mV and 20 to 30 Hz;
    100 μV/V from 300 mV to 600 mV and 20 to 30 Hz;
    510 μV/V at 2 mV from 40 Hz to 50 kHz;
    210 μV/V from 2 mV to 10 mV and 40 Hz to 50 kHz;
    85 μV/V from 10 mV to 100 mV and 40 Hz to 50 kHz;
    50 μV/V from 100 mV to 600 mV and 40 Hz to 50 kHz;
    1100 μV/V at 2 mV at 100 kHz;
    510 μV/V from 2 mV to 10 mV at 100 kHz;
    410 μV/V from 10 mV to 100 mV and 100 kHz to 200 kHz;
    205 μV/V from 100 mV to 600 mV and 100 kHz to 200 kHz;
    1250 μV/V at 2 mV at 200 kHz;
    620 μV/V from 2 mV to 10 mV at 200 kHz;
    1550 μV/V at 2 mV at 300 kHz;
    820 μV/V from 2 mV to 100 mV and 300 to 500 kHz;
    205 μV/V from 100 mV to 600 mV and 300 to 500 kHz;
    1550 μV/V at 2 mV at 500 kHz;
    2100 μV/V at 2 mV at 1 MHz;
    1000 μV/V from 2 mV to 600 mV at 1 MHz;
    310 μV/V from 0.6 V to 1000 V at 10 Hz;
    100 μV/V from 0.6 V to 1000 V from 20 to 40 Hz;
    20 μV/V from 0.6 V to 400 V and 50 Hz to 10 kHz;
    20 μV/V from 0.6 V to 60 V at 20 kHz;
    30 μV/V from 400 V to 1000 V at 50 Hz;
    25 μV/V from 60 V to 400 V at 20 kHz;
    40 μV/V from 400 V to 1000 V and 400 Hz to 20 kHz;
    30 μV/V from 0.6 V to 400 V at 50 kHz;
    85 μV/V from 400 to 1000 V at 50 kHz;
    45 μV/V from 0.6 V to 60 V at 100 kHz;
    55 μV/V from 60 V to 400 V at 100 kHz;
    125 μV/V from 400 V to 1000 V at 100 kHz;
    175 μV/V from 0.6 V to 60 V and 200 to 500 kHz;
    205 μV/V from 0.6 V to 20 V and 500 kHz to 1 MHz;
    600 μV/V from 0.2 V to 3 V at 3 MHz;
    900 μV/V from 0.2 V to 3 V at 10 MHz;
    1500 μV/V from 0.2 V to 3 V at 30 MHz;
    3000 μV/V from 0.2 V to 3 V at 50 MHz;
    3000 μV/V at 0.27 V at 70 MHz;
    9000 μV/V from 0.2 V  to 3 V at 100 MHz;
    50 μA/A from 100 μA to 20 A at 57 Hz
    85 μA/A from 100 μA to 20 A and 100 Hz to 1 kHz
    750 μA/A from 100 μA to 20 A and 1 kHz to 10 kHz
    300 μA/A from 10 mA to 300 mA at 30 kHz

    Inductors;
    Inductance;
    Comparison with a reference standard;
    Two terminal inductors at 1 kHz 

    from 0.1 mH to 100 mH and at 10 H

    CAPABILITY
    with Calibration and Measurement Capability of - 

    0.1% from 0.1 mH to 1 mH
    0.05% from 1 mH to 100 mH
    0.13% at 10 H


    Precision capacitors;
    Capacitance;
    Comparison with a reference standard;
    Three terminal capacitors from 40 Hz up to 1 kHz
    from 0.1 pF to 1.1 μF
    Two terminal capacitors from 50 Hz to 1 kHz
    from 1 pF to 110 μF

    CAPABILITY
    with Calibration and Measurement Capability of - 

    Three terminal capacitors
    30 μF/F + 0.1 fF from 0.1 pF up to 1000 pF
    0.01% from 1000 pF to 1.1 μF
    Two terminal capacitors
    (0.1% + 0.02 pF) from 1 pF to 110 μF

    High frequency electrical metrology - Communications, electromagnetic field strength and EMC test equipment
    Amplifiers; Artificial mains networks (AMN); Attenuators; Communications systems; Coupling/decoupling networks (CDN); Data transmission measuring equipment; Electrical fast transients (EFT) and surge generators; Electrical noise and interference measuring equipment; Flicker harmonics load unit; Harmonic emission compliance test systems; Impedance and reflection measuring equipment; Line impedance stabilisation networks (LISN); Line transmission measuring equipment; Power measuring equipment; Radio transmission measuring equipment; Short interruptions and voltage variations; Spectrum analysers; Voltage dips; Voltage fluctuation and flicker compliance test systems; Waveguide and coaxial components;
    Power;
    Comparison with a reference standard; Direct measurement by electrical input;
    CAPABILITY
    with Calibration and Measurement Capability of - 
    0.65% from 1 μW to 100 mW from D.C. to 30 MHz;
    0.6% from 1 μW to 2 W from 30 to 500 MHz;
    0.6% + 0.07% per GHz from 1 μW to 2 W from 500 MHz to 18 GHz (50 Ω coaxial);
    1.5% + 0.07% per GHz from 1 μW to 2 W from 8.2 GHz to 18 GHz ("X" and "P" band waveguides);
    10% from 2 W to 50 W from 30 MHz to 250 MHz
    4.5% from 2W to 15W from 800 MHz to 2.5 GHz 


    Internal reference impedance resistance; Reflection coefficient;
    Comparison with a reference standard; Direct measurement by electrical input;
    CAPABILITY
    with Calibration and Measurement Capability of -
    0.01 for reflection coefficient
    0.005 at 8.2 GHz to 18 GHz ("X" and "P" band waveguides) coupling factor, directivity and insertion loss of directional couplers


    Attenuation;
    Comparison with a reference standard; Direct measurement by electrical input;
    CAPABILITY
    with Calibration and Measurement Capability of - 

    0.003 dB + 0.0005 dB/ 10 dB from 0 to 60 dB at D.C and 10 Hz to 10 kHz;
    0.04 dB + 0.005 dB/ 10 dB above 60 dB, from 60 to 110 dB at D.C. and 10 Hz to 10 kHz;
    0.007 dB + 0.001 dB/ 10 dB from 0 to 70 dB at 10 kHz to 30 MHz;
    0.014 dB + 0.02 dB/ 10 dB above 70 dB, from 70 to 120 dB at 10 kHz to 30 MHz;
    0.02 dB + 0.02 dB/ 10 dB from 0 to 110 dB at 30 MHz to 18 GHz;
    0.24 dB + 0.3 dB/ 10 dB above 110 dB, from 110 to 120 dB at 30 MHz to 18 GHz

    Pressure metrology - Pressure and vacuum measuring equipment
    Pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges;
    Gauge pressure; High vacuum;
    By pressure calibrator; Comparison with dead weight tester; Comparison with reference instrument;
    AS1349; MSA Test Method 1; MSA Test Method 2
    CAPABILITY
    with Calibration and Measurement Capability of - 

    Pneumatic devices
    0.03 kPa from -100 kPa to 40 kPa
    0.04% + 0.001 kPa from 40 kPa to 200 kPa
    0.1 kPa from 200 kPa to 800 kPa
    0.015% from 800 kPa to 83.5 MPa

    Hydraulic devices
    0.07 kPa from 45 kPa to 300 kPa;
    0.01% from 300 kPa to 83.5 MPa
    Temperature metrology - Ancillary temperature measuring equipment
    Resistance bridges;
    Resistance to temperature conversion;
    Direct measurement by electrical input;
    Portable a.c. temperature bridges from 1 to 500 Ω

    CAPABILITY
    with Calibration and Measurement Capability of - 
    5 mΩ from 1 to 500 Ω



    Portable potentiometers;
    Volt to temperature conversion;
    Direct measurement by electrical input;
    from 0 to 100 mV
    CAPABILITY
    with Calibration and Measurement Capability of - 

    0.001% or 1 μV (whichever is the greater) from 0 to 100 mV


    Multi-channel thermocouple data recorders; Process calibrators;
    Resistance to temperature conversion; Volt to temperature conversion;
    Direct measurement by electrical input;
    from -270 ºC to 1370 ºC
    CAPABILITY
    with Calibration and Measurement Capability of -

    0.25% of range plus 2 digits from -270 ºC to 1370 ºC


    Digital voltmeters (DVM) and digital multimeters (DMM);
    Volt to temperature conversion;
    Direct measurement by electrical input;
    up to 100 mV


    CAPABILITY
    with Calibration and Measurement Capability of -

    10 μV/V or 1 μV (whichever is greater) up to 100 mV

    Temperature metrology - Temperature measuring equipment
    Base metal thermocouples; Digital temperature measuring systems;
    Temperature;
    Measurement against reference standard;
    -50 ºC to 650 ºC


    CAPABILITY
    with Calibration and Measurement Capability of - 
    0.3 ºC + 0.1%T from -50 ºC to 300 ºC
    0.6 ºC + 0.1%T from 300 ºC to 500 ºC
    1 ºC from 500 ºC to 650 ºC 


    Temperature metrology - Temperature standards and reference equipment
    Dry block calibrators;
    Temperature;
    To be determined;
    Measured against PRT reference standard from -50 ºC to 650 ºC 


    CAPABILITY
    with Calibration and Measurement Capability of - 

    0.15 ºC + 0.05%T from -50 ºC to 300 ºC
    0.35 ºC + 0.05%T from 300 ºC to 650 ºC 


    Temperature reference standards - Fixed points;
    Temperature;
    To be determined;
    CAPABILITY
    with a Calibration and Measurement Capability of -
    0.05 ºC at 0 ºC
    Time and frequency metrology - Frequency and time standards
    Frequency standards;
    Frequency;
    Measurement against reference standard;
    up to 10 MHz


    CAPABILITY
    with Calibration and Measurement Capability of - 

    1 in 1011 up to 10 MHz


    Signal sources;
    Frequency; Modulation; Power; Voltage;
    Measurement against reference standard;
    Frequency characteristics up  to 18 GHz
    Voltage measurements at frequencies up to 30 MHz
    Power measurements at frequencies from 30 MHz to 18 GHz
    Amplitude and frequency modulation from 1 MHz to 18 GHz

    CAPABILITY
    with Calibration and Measurement Capability of - 

    Frequency characteristics 
    5 in 1011 up to 10 MHz;
    5 in 1010 from 10 MHz to 18 GHz

    Voltage measurements
    275 μV/V at 2 mV at 20 Hz
    250 μV/V at 2 mV from 40 Hz to 50 kHz
    260 μV/V at 2 mV at 100 kHz
    290 μV/V at 2 mV at 200 kHz
    320 μV/V at 2 mV at 300 kHz
    520 μV/V at 2 mV at 500 kHz
    140 μV/V from 10 mV to 30 mV at 10 Hz
    100 μV/V from 10 mV to 30 mV at 20 Hz
    80 μV/V from 10 mV to 30 mV from 40 Hz to 50 kHz
    90 μV/V from 10 mV to 30 mV at 100 kHz
    130 μV/V from 10 mV to 30 mV at 200 kHz
    165 μV/V from 10 mV to 30 mV at 300 kHz
    350 μV/V from 10 mV to 30 mV at 500 kHz
    1200 μV/V from 10 mV to 30 mV at 1 MHz
    55 μV/V from 30 mV to 300 mV at 10 Hz
    45 μV/V from 30 mV to 300 mV at 20 Hz
    55 μV/V from 30 mV to 300 mV from 40 Hz to 100 kHz
    95 μV/V from 30 mV to 300 mV at 200 kHz
    150 μV/V from 30 mV to 300 mV at 300 kHz
    350 μV/V from 30 mV to 300 mV at 500kHz
    1330 μV/V from 30 mV to 300 mV at 1 MHz
    55 μV/V from 300 mV to 200 V at 10 Hz
    50 μV/V from 30 mV to 300 V from 20 Hz to 50 kHz
    45 μV/V from 30 mV to 700m V from 100 kHz to 300 kHz
    65 μV/V from 30 mV to 700m V at 500 kHz
    100 μV/V from 30 mV to 700 mV at 1 MHz
    60 μV/V from 700 mV to 2.2 V at 100 kHz
    290 μV/V from 700 mV to 2.2 V at 200 kHz
    350 μV/V from 700 mV to 2.2 V at 300 kHz
    1800 μV/V from 700 mV to 2.2 V at 500 kHz
    5300 μV/V from 700 mV to 2.2 V at 1 MHz
    50 μV/V from 2.2 V to 7 V at 100 kHz
    70 μV/V from 2.2 V to 7 V at 200 kHz
    75 μV/V from 2.2 V to 7 V at 300 kHz
    700 μV/V from 2.2 V to 7 V from 500 kHz to 1 MHz
    50 μV/V from 7 V to 300 V at 100 kHz
    65 μV/V from 7 V to 100 V at 200 kHz
    70 μV/V from 7 V to 60 V from 300 kHz to 500 kHz
    75 μV/V from 7 V to 22 V at 1 MHz
    50 μV/V from 300 V to 1000 V at 40 Hz to 50 kHz
    75 μV/V from 300 V to 1000 V at 100 kHz
    700 μV/V from 0.2 V to 3 V from 1 MHz to less than 10 MHz
    1000 μV/V from 0.2 V to 3 V from 10 MHz to less than 30 MHz
    1900 μV/V from 0.2 V to 3 V at 30 MHz




    Incremental attenuation
    0.003 dB + 0.0005 dB/ 10 dB from 0 to 60 dB at D.C and 10 Hz to 10 kHz;
    0.04 dB + 0.005 dB/ 10 dB above 60 dB, from 60 to 110 dB at D.C. and 10 Hz to 10 kHz;
    0.007 dB + 0.001 dB/ 10 dB from 0 to 70 dB at 10 kHz to 30 MHz;
    0.014 dB + 0.02 dB/ 10 dB above 70 dB, from 70 to 120 dB at 10 kHz to 30 MHz;
    0.02 dB + 0.02 dB/ 10 dB from 0 to 110 dB at 30 MHz to 18 GHz;
    0.24 dB + 0.3 dB/ 10 dB above 110 dB, from 110 to 120 dB at 30 MHz to 18 GHz



    Power measurements
    0.65% from 1 μW to 100 mW from D.C. to 30 MHz;
    0.6% from 1 μW to 2 W from 30 to 500 MHz;
    0.6% + 0.07% per GHz from 1 μW to 2 W from 500 MHz to 18 GHz (50 Ω coaxial);
    1.5% + 0.07% per GHz from 1 μW to 2 W from 8.2 GHz to 18 GHz ("X" and "P" band waveguides);
    10% from 2 W to 50 W from 30 MHz to 250 MHz
    4.5% from 2W to 15W from 800 MHz to 2.5 GHz



    Amplitude and frequency modulation 1% from 1 MHz to 18 GHz

    Time and frequency metrology - Frequency, time and waveform measuring equipment
    Frequency meters;
    Frequency;
    Measurement against reference standard;
    at frequencies up to 18 GHz


    CAPABILITY
    with Calibration and Measurement Capability of -
    1 in 107 up to 18 GHz



    Clocks and timers;
    Time interval;
    Measurement against reference standard;
    Stopwatches from 1 s to 3 h

    Stop clocks from 0.5 s to 1 h

    CAPABILITY
    with Calibration and Measurement Capability of - 

    Stopwatches
    0.040 s from 1 s to 30 min
    0.30 s from 30 min to 3 h
    Stop clock
    0.025 s from 0.5 s to 1 h


    Frequency analysers; Oscilloscopes; Waveform measuring instruments;
    Distortion; Frequency; Rise/fall time;
    Measurement against reference standard;
    Frequency and Timing characteristics up to 18 GHz
    Distortion with an input voltage range 50 mV to 300 V and 10 Hz to 1 MHz
    Rise-time from a minimum of 25 ps


    CAPABILITY
    with Calibration and Measurement Capability of - 

    Frequency characteristics
    5 in 1011 up to 10 MHz
    5 in 1010 from 10 MHz to 18 GHz

    Timing characteristics 
    5 in 1011 up to 10 MHz
    5 in 1010 from 10 MHz to 18 GHz

    Distortion
    0.1 dB from -10 dB to -60 dB
    0.3 dB from -60 dB to -80 dBRise-time
    9 ps from 25 ps


    Counters; Stroboscopes;
    Frequency;
    Measurement against reference standard;
    up to 18 GHz


    CAPABILITY
    with Calibration and Measurement Capability of - 

    5 in 1011 up to 10 MHz;
    5 in 1010 from 10 MHz to 18 GHz


    Tachometers;
    Rotational speed;
    Comparison with a reference standard;
    Optical tachometers
    from 0.017 Hz to 16666.7 Hz
    (1 rpm to 1000000 rpm)

    CAPABILITY
    with Calibration and Measurement Capability of - 
    17 μHz from 0.017 Hz to 1.67 Hz
    (0.001 rpm from 1 rpm to 100 rpm)
    10 μHz/Hz from 1.67 Hz to 16666.7 Hz
    (0.001% from 100 rpm to 1000000 rpm)



    Time interval meters;
    Time interval;
    Measurement against reference standard;
    10 ns to 20 000 s


    CAPABILITY
    with Calibration and Measurement Capability of - 

    5 in 1011 + 5 ns from 10 ns to 20 000 s


  • ISO/IEC 17025 (2005)
    Manufactured Goods
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    Evaluation of electrical appliances and devices - Performance
    External power supplies, stabilisers and related items;
    Drift; Electrical parameters; Frequency and time interval; Input impedance; Insulation resistance; Line regulation; Load regulation; Meter accuracy; Power; Power factor; Recovery time - Transient response; Ripple - Noise;
    Not applicable;
    Performance tests on power supplies by the methods of Calibration Procedure CP910125 or Manufacturers ; Performance Verification
    A.C/D.C power, 
    A.C/D.C voltage
    A.C/D.C current