SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

  • ISO/IEC 17025 (2017) - The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
    Calibration
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    Flow metrology - Flow measuring devices and systems
    Air sampling pumps and meters;
    Flow rate;
    Comparison with a reference meter;
    EP0140 Flow rate: 1 L/min to 3 L/min
    Timer: minimum 2 hours
    CAPABILITY
    Calibration of air sampling pumps using air at atmospheric conditions
    with Calibration and Measurement Capability of -
    Sampling pump flow rate: 1.2% of flow from 1 L/min to 3 L/min
    Sampling pump timer: (0.05% reading + 0.5 minutes) over a minimum of 2 hours

    SUSPENDED
    Temperature metrology - Ancillary temperature measuring equipment
    Process calibrators;
    Resistance to temperature conversion;
    Direct measurement by electrical input;
    Calibration of process calibrators by electrical simulation and measurement
    Thermocouple input /output
     From -250 ºC to +2 316 ºC
     RTD input
    From -200 ºC to 800 ºC
     RTD output
     From -200 ºC to 800 ºC
    CAPABILITY
    With Calibration and Measurement Capability of -
    Calibration of process calibrators by electrical simulation and measurement
    Thermocouple input /output
    1.0 ºC
    RTD input
    0.3 ºC
    RTD output
    0.1 ºC
    SUSPENDED
    Temperature metrology - Humidity measuring equipment
    Relative humidity sensors;
    Relative humidity (RH);
    To be determined;
    Calibration of relative humidity sensors in air
    From 23 ºC to 80 ºC
     in the range 10 %RH to 95 %RH
    CAPABILITY
    With Calibration and Measurement Capability of -
     3.0 %RH
    SUSPENDED
    Temperature metrology - Temperature measuring equipment
    Digital temperature measuring systems; Liquid in glass (LIG) thermometers; Surface probes;
    mV over oC range; Temperature;
    Direct temperature and electrical measurement against reference standard; Measurement against reference standard;
    Surface probes
    From +20 ºC to +100 ºC
    Digital temperature indicator systems 
    From -40 ºC to 1100 ºC
    CAPABILITY
    With Calibration and Measurement Capability of -
    Surface probes
     3 ºC 
    Liquid-in-glass thermometers 
     0.02 ºC at 0 ºC
    Digital temperature indicator systems 
     0.2 ºC from -40 ºC to +250 ºC
     2.0 ºC from 250 ºC to 1100 ºC
    SUSPENDED
    Temperature metrology - Verification of controlled enclosures
    Baths; Furnaces; Ovens;
    Spatial uniformity; Temperature; Temporal uniformity;
    Direct temperature measurement;
    By the method of -
    AS 2853
    From -40 ºC to 1 100 ºC
     
     
    CAPABILITY
    With Calibration and Measurement Capability of -
    1.3 ºC from -40 ºC to 300 ºC
     5.4 ºC from 300 ºC to 1 100 ºC
     Spatial Variation tests
      5.4 ºC
     Temporal variation tests
      0.7 ºC
    SUSPENDED

    Environmental chambers - Humidity;
    Fluctuation; Gradient; Humidity;
    By methods of AS/IEC 60068.3.6;
    From 23 ºC to 80 ºC
    in the range 10 % to 95 %RH
    for humidity, relative humidity gradient tests, relative humidity fluctuation tests
    CAPABILITY
    With Calibration and Measurement Capability of -
    Humidity and  Relative humidity gradient tests
    3.0 %RH
     Relative humidity fluctuation tests
     1.2 % RH
    SUSPENDED

    Environmental chambers - Temperature;
    Fluctuation; Gradient;
    Direct temperature measurement;
    By the methods of -
    AS 60068.3.5, IEC 60068.3.5
    From -40 ºC to 300 ºC
     Temperature gradient tests and temperature fluctuation tests
    From -40 ºC to 300 ºC
     
    CAPABILITY
    With Calibration and Measurement Capability of -
    1.3 ºC
    Temperature gradient tests
     0.5 ºC
    Temperature fluctuation tests
     0.1 ºC