Back to Search Results


Address Details:
3/36 Achievement Crescent
ACACIA RIDGE, QLD 4110
AUSTRALIA Map
www.auscal.com.au

Contact Details:
Mr Tim Kennon
+61(07) 32166642

Availability:
Services available to external clients

SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.



ISO/IEC 17025 (2005)
Calibration
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
Dimensional metrology - Engineering equipment and precision instruments
Electronic calipers; Vernier calipers;
Length measurements;
Comparison with a reference standard;
including compliance to  AS 1984, BS 887, and JIS 7507
Up to 500 mm
CAPABILITY
with Calibration and Measurement Capability of -
(10 + 0.025L) μm for indication errors up to 500 mm where L is the scale value in mm

Dial gauges;
Length measurements;
Comparison with a reference standard;
including compliance to  AS 2103
Up to 100 mm
CAPABILITY
with Calibration and Measurement Capability of -
(1 + 0.025L) μm for indication errors up to 100 mm where L is the scale value in mm

Steel rulers and measuring tapes;
Length measurements;
Comparison with a reference standard;
Steel rules
up to 2 m
CAPABILITY
with Calibration and Measurement Capability of -
Retractable steel pocket rules
(0.15 + 0.13L) mm where L is the scale value in m
Steel rules
25 μm up to 2 m in length
Force metrology - Force measuring and testing equipment
Load cells; Load measuring rings;
Force in compression; Force in tension;
Comparison measurement with reference load cell;
Calibration of devices such as load measuring rings
for soil testing machines in tension and compression
to class AA and 
to class A requirements of AS 2193

Electronic load cells and hydrostatic weighing units
including those in batching plants and aircraft weighing kits

In tension and compression
at forces up to 500 kN to class AA and up to 3.3 MN 
to class A requirements of AS 2193
CAPABILITY
With Calibration and Measurement Capability of -
Tension
0.17% of reading  from 0.01 N to 1000 kN 
0.25% of reading above 1000 kN to 3.3 MN
Class A up to 3.3 MN
Class AA up to 500 kN

Compression
0.17% of reading  from 0.01 N to 500 kN 
0.25% of reading above 500 kN to 10 MN
Class AA up to 500 kN
Class A up to 4.5 MN
Class B up to 10 MN
Force metrology - Force measuring and testing equipment
Compression and universal machines in compression; Hydraulic rams and jacks; Tension and universal machines in tension;
Force in compression; Force in tension;
Comparison measurement with reference load cell;
Tension and universal machines in tension
AS 2193 and including testing to ISO 7500-1 and ASTM E4
Compression and universal machines in compression
AS 2193 and including testing to ISO 7500-1 and ASTM E4
Verification of compression testing machines for concrete
including self-alignment and restraint on tilt tests for compliance
with BS 1881 Part 115
Hydraulic rams and jacks
Including devices used in pre and post-stressing jacks
and jacking systems used for stressing tendons in concrete
 to Class A requirements of AS 2193
Tension up to 3.3 MN
Compression up to 10 MN


including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
Tension
0.17% of reading  from 0.01 N to 1000 kN
0.25% of reading above 1000 kN to 3.3 MN
Class A up to 3.3 MN
Class AA up to 500 kN

Compression
0.17% of reading  from 0.01 N to 500 kN
0.25% of reading above 500 kN to 10 MN
Class AA up to 500 kN
Class A up to 4.5 MN
Class B up to 10 MN

Force metrology - Hardness standards and equipment
Rockwell hardness machines;
Rockwell hardness;
Comparison with a reference standard;
Partial and complete calibration except indenter dimensions
clause (2.4.1.2b) including compliance to AS 1815.2
including on site calibrations



Force metrology - Hardness standards and equipment
Brinell hardness machines;
Brinell hardness;
Comparison with a reference standard;
Partial and complete calibration including compliance to AS 1816.2



including on site calibrations



Force metrology - Hardness standards and equipment
Vickers micro-hardness machines;
Vickers hardness;
Comparison with a reference standard;
(less than HV 0.2)
Direct verification except indenter dimensions including compliance to ISO 146-2
including on site calibrations



Force metrology - Hardness standards and equipment
Vickers low-load hardness machines;
Vickers hardness;
Comparison with a reference standard;
(HV 0.2 to HV 5)
Direct verification and indirect verification except indenter dimensions
including compliance to ISO 146
9.8 N to 49 N
including on site calibrations



Force metrology - Hardness standards and equipment
Rockwell superficial hardness machines;
Rockwell hardness;
Comparison with a reference standard;
Partial and complete calibration including compliance to AS 2025
including on site calibrations




Indenters; Portable Brinell measuring microscopes;
Brinell hardness;
Comparison with a reference standard;
Visual examination for Indenters only
Brinell Measuring microscopes are calibrated



Force metrology - Hardness standards and equipment
Vickers hardness machines;
Vickers hardness;
Comparison with a reference standard;
Partial and complete calibration except indenter dimensions
clause (2.4.2.2)  including compliance to AS 1817.2
 9.8 N to 1176 N
including on site calibrations



Mass - Determination of mass and calibration of weighing devices
Industrial weighing devices; Laboratory weighing devices; Precision laboratory balances;
Mass;
Gravimetric measurement against reference mass;
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
Precision laboratory balances
2 in 106 or 20 μg (whichever is greater) up to 200 g
Industrial balances
1 in 105 or 1 mg (whichever is greater) up to 30 kg
Industrial weighing appliances
5 in 105 or 100 mg (whichever is greater) up to 400 kg

Industrial mass standards;
Mass;
Gravimetric measurement against reference mass;
From 1 g up to 20 kg
CAPABILITY
with Calibration and Measurement Capability of -
0.9 mg from 1 g up to 100 g;
20 mg from 100 g to 2 kg;
130 mg from 2 kg to 20 kg
Pressure metrology - Pressure and vacuum measuring equipment
Digital pressure gauges; Mechanical pressure gauges; Pressure control devices; Pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges;
Gauge pressure;
By pressure calibrator;
AS 1349 -100 kPa to 70 MPa
including on site calibrations



CAPABILITY
With Calibration and Measurement Capability of-
0.05% of reading from 100 kPa to 70 MPa
0.23% of reading from -100 kPa to -20 kPa and 20 kPa to 100 kPa
0.46% of reading or 80 Pa (whichever is greater) from -20 kPa to 20 kPa

For on site calibrations
Calibration of industrial gauges
With Calibration and Measurement Capability of-
0.23% of reading from -100 kPa to -20 kPa and 20 kPa to 70 MPa
0.46% or 80 Pa (whichever is greater) from -20 kPa to 20 kPa

Torque - Torque measuring and testing equipment
Torque wrenches;
Torque;
Comparison with a reference standard;
including compliance to AS 4115
from 0.1 N.m to 1350 N.m
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of-
1.5% of reading from 0.1 N.m to 1.2 N.m
0.4% of reading from 1.2 N.m to 1350 N.m