Back to Search Results


Address Details:
745 Springvale Road
MULGRAVE, VIC 3170
AUSTRALIA Map
http://www.keysight.com/

Contact Details:
Mr Leigh Mackinnon
+61 1800225574

Availability:
Services available to external clients

SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.



ISO/IEC 17025 (2005)
Calibration
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
DC and low frequency electrical metrology - Electrical instrument calibrators
Instrument calibrators;
AC current; AC voltage; DC current; DC voltage; Resistance;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
D.C voltage
5 μV/V + 0.2 μV up to 1 V
3 μV/V from 1 V to 1000 V
7 μV/V from 1000 V to 1020 V
A.C. voltage
From 1 mV to 10 mV
380 μV/V at 10 Hz to 20 kHz
450 μV/V at 30 kHz to 50 kHz
720 μV/V at 100 kHz
950 μV/V at 300 kHz to 500 kHz
From 10 mV to 0.1 V
200 μV/V at 10 Hz to 20 kHz
300 μV/V at 30 kHz to 50 kHz
500 μV/V at 100 kHz
700 μV/V at 300 kHz to 500 kHz
1.1 mV/V at 1 MHz
From 0.1 V to 1 V
140 μV/V at 10 Hz to 20 kHz
220 μV/V at 30 kHz to 50 kHz
420 μV/V at 100 kHz
710 μV/V at 300 kHz to 500 kHz
1.1 mV/V at 1 MHz
From 1 V to 10 V
42 μV/V at 10 Hz to 30 Hz
28 μV/V at 40 Hz to 30 kHz
43 μV/V at 50 kHz to 100 kHz
120 μV/V at 300 kHz
240 μV/V at 500 kHz
650 μV/V at 1MHz
From 10 V to 100 V
420 μV/V at 10 Hz to 30 Hz
300 μV/V at 40 Hz to 30 kHz
600 μV/V at 50 kHz
300 μV/V at 100 kHz
950 μV/V at 300 kHz
2.2 mV/V at 500 kHz
6.2 mV/V at 1 MHz
From 100 V to 700 V
48 μV/V at 10 Hz to 55 Hz
34 μV/V at 300 Hz to 30 kHz
41 μV/V at 50 kHz
77 μV/V at 100 kHz
280 μV/V at 200 kHz
From 700 V to 1000 V
43 μV/V at 40 Hz to 1 kHz
54 μV/V at 5 kHz
45 μV/V at 8 kHz
46 μV/V at 10 kHz
54 μV/V at 20 kHz
86 μV/V at 30 kHz
D.C. current
24 μA/A from 1 μA to 1 mA
13 μA/A from 1 mA to 0.1 A
17 μA/A from 0.1 A to 1 A
29 μA/A from 1 A to 10 A
67 μA/A from 10 A to 20 A
220 μA/A at 20 A
A.C. current
From 0.1 mA to 1 mA
150 μA/A at 10 Hz to 30 Hz
110 μA/A at 40 Hz to 1 kHz
560 μA/A at 5 kHz
2200 μA/A at 10 kHz
From 1 mA to 10 mA
140 μA/A at 10 Hz to 30 Hz
95 μA/A at 40 Hz to 1 kHz
150 μA/A at 5 kHz
310 μA/A at 10 kHz
From 10 mA to 100 mA
130 μA/A at 10 Hz to 30 Hz
88 μA/A at 40 Hz to 1 kHz
130 μA/A at 5 kHz
300 μA/A at 10 kHz
From 0.1 A to 1 A
140 μA/A at 10 Hz to 30 Hz
89 μA/A at 40 Hz to 1 kHz
140 μA/A at 5 kHz
410 μA/A at 10 kHz
From 1 A to 10 A
200 μA/A at 10 Hz to 30 Hz
130 μA/A at 40 Hz to 1 kHz
250 μA/A at 5 kHz
300 μA/A at 10 kHz
From 10 A to 20 A
280 μA/A at 10 Hz to 30 Hz
230 μA/A at 40 Hz to 1 kHz
300 μA/A at 5 kHz
390 μA/A at 10 kHz
 At 20 A
310 μA/A at 20 A at 45 Hz to 1 kHz
1000 μA/A at 20 A at 5 kHz
Resistance
15 μΩ/Ω + 20 μΩ up to 1.9 Ω
9 μΩ/Ω from 1.9 Ω to19 Ω
7 μΩ/Ω from 19 Ω to 190 Ω
4 μΩ/Ω from 190 Ω to 19 kΩ
7 μΩ/Ω from 19 kΩ to 190 kΩ
13 μΩ/Ω from 190 kΩ to 1.9 MΩ
24 μΩ/Ω from 1.9 MΩ to 19 MΩ
95 μΩ/Ω from 19 MΩ to 100 MΩ
630 μΩ/Ω from 100 MΩ to 290 MΩ
1.2 mΩ/Ω from 400 MΩ to 640 MΩ
1.8 mΩ/Ω from 640 MΩ to 1100 M Ω
DC and low frequency electrical metrology - Electrical measurement and test equipment
LCR meters;
Capacitance;
Direct measurement against a reference standard;
0.001 μF to 10 μF
CAPABILITY
with Calibration and Measurement Capability of -
3% from 0.001 μF to 10 μF


Capacitance; Dissipation factor; Inductance; Resistance;
Comparison with a reference standard;
CAPABILITY
Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -
Inductance
4.2 mH/H at 100 μH to 300 μH at 1 kHz
3.0 mH/H from 300 μH to 3 mH at 1 kHz
2.2 mH/H from 3 mH to 10 H at 1 kHz
Capacitance
0.7 fF/pF for 1 pF at 1 kHz
4.5 fF/pF for 1 pF from 1 kHz to 1 MHz
15.2 fF/pF for 1 pF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.4 fF/pF for 10 pF & 100 pF at 1 kHz
0.9 fF/pF for 10 pF & 100 pF from 1 kHz to 1 MHz
2.5 fF/pF for 10 pF & 100 pF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.6 pF/nF for 1 nF at 1 kHz to 1 MHz
6.3 pF/nF for 1 nF at 3 MHz, 5 MHz, 10 MHz & 13 MHz
0.6 pF/nF for 10 nF at 20 Hz to 10 kHz
1.9 pF/nF for 10 nF from 10 kHz to 100 kHz
0.5 pF/nF for 100 nF at 20 Hz to 1 kHz
1.3 pF/nF for 100 nF from 1 kHz to 10 kHz
3.5 pF/nF for 100 nF from 10 kHz to 100 kHz
1.0 nF/μF for 1 μF from 20 Hz to 10 kHz
Dissipation Factor
0.0005 for 1 pF at 1.6 kHz to 1 MHz
0.0012 for 1 pF from 1 MHz to 13 MHz
0.0004 for 10 pF at 200 Hz to 1 MHz
0.0011 for 10 pF from 1 MHz to 13 MHz
0.0049 for 100 pF at 20 Hz to 1 kHz
0.0005 for 100 pF from 1 kHz to 1 MHz
0.0013 for 100 pF from 1 MHz to 13 MHz
0.0003 for 10 nF at 1 kHz
0.0004 for 100 nF at 1kHz
0.0005 for 1000 pF at 1kHz
A.C. Resistance
220 μΩ for 0.1 Ω at 1 kHz
2.9 mΩ for 1 Ω from 5 Hz to 1 MHz
2.2 mΩ for 10 Ω from 1 MHz to 13 MHz
190 mΩ for 100 Ω from 5 Hz to 1 MHz
510 mΩ for 100 Ω from 1 MHz to 13 MHz
2.8 Ω for 1 kΩ from 5 Hz to 1 MHz
4.2 Ω for 1 kΩ from 1 MHz to 13 MHz
28 Ω for 10 kΩ from 5 Hz to 1 MHz
550 Ω for 100 kΩ from 5 Hz to 1 MHz

Phase angle meters;
Phase angle;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
0.15º at 50 Hz up to 240 V and 3 A

Appliance testers; Insulation resistance test equipment;
AC voltage; Resistance;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Insulation resistance testers up to 1 kV
0.60% up to 100 kΩ
0.12% from 100 kΩ to 100 MΩ
0.51% from 100 MΩ to 1GΩ
0.77% from 1 GΩ to 10 GΩ
Insulation resistance testers from 1 kV to 5 kV
0.77% up to 10 GΩ
3.0% from 10 GΩ to 100 GΩ
4.7% from 100 GΩ to 9 TΩ
Insulation resistance testers from 5 kV to 10 kV
1.9% up to 10 GΩ
3.0% from 10 GΩ to 100 GΩ
4.7% from 100 GΩ to 9 TΩ
Output voltage for insulation resistance up to 10 kV
0.22% up to 1 kV
0.65% from 1 kV to 10 kV

Appliance testers; LCR meters; Ohm meters;
Resistance;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
0.01% from 1 mΩ to 100 mΩ

Appliance testers; Data recorders; Digital multimeters (DMM); Insulation resistance test equipment; Phase angle meters; Power analysers; Power supplies; RCD testers; Residual current circuit breaker testers; Voltmeters;
AC voltage; DC voltage;
Comparison with a reference standard;
CAPABILITY
Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -
D.C.
10 μV/V + 0.4 μV from 1 μV to 0.22 V
6 μV/V from 0.22 V to 2.2 V
5 μV/V from 2.2 V to 22 V
8 μV/V from 22 V to 1000 V
A.C.
From 10 μV to 2.2 mV
3.0 mV/V at 10 Hz to 100 kHz
6.1 mV/V from 100 kHz to 300 kHz
12 mV/V from 300 kHz to 500 kHz
13 mV/V from 500 kHz to 1 MHz
From 2.2 mV to 22 mV
500 μV/V at 10 Hz to 50 kHz
800 μV/V from 50 kHz to 100 kHz
1.6 mV/V from 100 kHz to 300 kHz
2.4 mV/V from 300 kHz to 500 kHz
3.7 mV/V from 500 kHz to 1 MHz
From 22 mV to 0.22 V
300 μV/V at 10 Hz to 50 kHz
600 μV/V from 50 kHz to 100 kHz
1 mV/V from 100 kHz to 300 kHz
1.5 mV/V from 300 kHz to 500 kHz
2.9 mV/V from 500 kHz to 1 MHz
From 0.22 V to 2.2 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
500 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.9 mV/V from 500 kHz to 1 MHz
From 2.2 V to 22 V
300 μV/V at 10 Hz to 50 kHz
100 μV/from 50 kHz to 100 kHz
300 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.7 mV/V from 500 kHz to 1 MHz
From 22 V to 220 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
900 μV/V from 100 kHz to 300 kHz
4.4 mV/V from 300 kHz to 500 kHz
8.0 mV/V from 500 kHz to 1 MHz
From 220 V to 750 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 50 kHz
2.3 mV/V from 50 kHz to 100 kHz
From 750 V to 1000 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 30 kHz

Appliance testers; Data recorders; Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters; Phase angle meters; Power analysers; Power supplies; RCD testers; Residual current circuit breaker testers;
Resistance;
Comparison with a reference standard;
CAPABILITY
Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -
77 μΩ/Ω + 20 μΩ up to 1 Ω
50 μΩ/Ω from 1 Ω to 1.9 Ω
25 μΩ/Ω from 1.9 Ω to 10 Ω
45 μΩ/Ω from 10 Ω to 19 Ω
21 μΩ/Ω from 19 Ω to 100 Ω
15 μΩ/Ω from 100 Ω to 100 kΩ
19 μΩ/Ω from 100 kΩ to 190 kΩ
24 μΩ/Ω from 190 kΩ to 1 MΩ
120 μΩ/Ω from 1 MΩ to 1.9 MΩ
74 μΩ/Ω from 1.9 MΩ to 10 MΩ
640 μΩ/Ω from 10 MΩ to 19 MΩ
600 μΩ/Ω from 19 MΩ to 100 MΩ
6.1 mΩ/Ω from 100 MΩ to 1 GΩ

Ammeters;
AC current;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Multiple turn clamp on meters
0.5% from 20 A to 1 000 A

Ammeters; Appliance testers;
DC current;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Multiple turn clamp on meters
0.2% from 20 A to 1000 A
Ground bond current testers
1.73% + 0.35 A up to 25 A
1.73% + 0.7 A from 25 A to 30 A

Ammeters; Appliance testers; Data recorders; Insulation resistance test equipment; Phase angle meters; Power analysers; Power supplies; RCD testers; Residual current circuit breaker testers;
AC current; DC current;
Comparison with a reference standard;
CAPABILITY
Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -
D.C.
24 μA/A from 1 μA to 220 μA
13 μA/A from 220 μA to 22 mA
18 μA/A from 22 mA to 220 mA
30 μA/A from 220 mA to 2.2 A
78 μA/A from 2.2 A to 11 A
220 μA/A from 11 A to 20 A
A.C.
From 1 μA to 220 μA
400 μA/A at 10 Hz to 20 Hz
200 μA/A from 20 Hz to 1 kHz
400 μA/A from 1 kHz to 5 kHz
1500 μA/A from 5 kHz to 10 kHz
From 220 μA to 220 mA
300 μA/A at 10 Hz to 20 Hz
200 μA/A from 20 Hz to 1 kHz
300 μA/A from 1 kHz to 5 kHz
1500 μA/A from 5 kHz to 10 kHz

From 220 mA to 2.2 A
300 μA/A at 20 Hz to 1 kHz
500 μA/A from 1 kHz to 5 kHz
7100 μA/A from 5 kHz to 10 kHz
From 2.2 A to 11 A
400 μA/A at 40 Hz to 1 kHz
500 μA/A from 1 kHz to 5 kHz
3700 μA/A from 5 kHz to 10 kHz
From 11 A to 20 A
500 μA/A at 45 Hz to 1 kHz
1500 μA/A from 1 kHz to 5 kHz

Watt meters;
Active power; Power factor;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
DC power wattmeters 0.15%
AC power wattmeters 0.20%
up to 600 V and 20 A, DC to 50 Hz (to a maximum of 12 kW) at PF = 1 only
DC and low frequency electrical metrology - Electrical standards
Voltage standards - E.M.F. reference devices;
Voltage;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
2.5 μV at 1 V nominal
25 μV at 10 V nominal

Conductance boxes; Current shunts; Precision resistors; Resistance boxes;
Resistance;
Direct measurement against a reference standard;
CAPABILITY
Including DC shunts up to 100 A
with Calibration and Measurement Capability of -
0.01% from 1 mΩ to 100 mΩ

Conductance boxes; Precision resistors; Resistance boxes;
Resistance;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
at decade values of -
16 μΩ/Ω at 1 Ω
7 μΩ/Ω at 10 Ω
8 μΩ/Ω at 100 Ω
5 μΩ/Ω at 1 kΩ
3 μΩ/Ω at 10 kΩ
6 μΩ/Ω at 100 kΩ
9 μΩ/Ω at 1 MΩ
60 μΩ/Ω at 10 MΩ
230 μΩ/Ω at 100 MΩ
3.2 mΩ/Ω at 1 GΩ
within the ranges of -
77 μΩ/Ω + 5 μΩ up to 1 Ω
25 μΩ/Ω from 1 Ω to 10 Ω
22 μΩ/Ω from 10 Ω to 100 Ω
13 μΩ/Ω from 100 Ω to 100 kΩ
20 μΩ/Ω from 100 kΩ to 1 MΩ
62 μΩ/Ω from 1 MΩ to 10 MΩ
790 μΩ/Ω from 10 MΩ to 100 MΩ
5.2 mΩ/Ω from 100 MΩ to 1 GΩ
AC Resistance
220 μΩ for 0.1 Ω at 1 kHz
2.9 mΩ for 1 Ω at 1 kHz to 1 MHz
19 mΩ for 10 Ω at 1 kHz to 1 MHz
190 mΩ for 100 Ω at 1 kHz to 1 MHz
2.8 Ω for 1 kΩ at 1 kHz to 1 MHz
28 Ω for 10 kΩ at 1 kHz to 1 MHz
550 Ω for 100 kΩ at 1 kHz to 100 kHz

AC/DC transfer instruments;
Voltage AC-DC difference;
Direct measurement against a reference standard;
CAPABILITY
Thermal converters with BNC input connectors
with Calibration and Measurement Capability of -
0.18 % from 0.5 V to 3.0 V and from 1 kHz to 1 MHz
0.26 % from 0.5 V to 3.0 V at 5, 10 & 30 MHz
0.42 % from 0.5 V to 3.0 V at 50 MHz
0.64 % from 0.5 V to 3.0 V at 70 MHz & 80 MHz

Inductors;
Inductance;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
4.2 mH/H at 100 μH to 300 μH at 1 kHz
3.0 mH/H from 300 μH to 3 mH at 1 kHz
2.2 mH/H from 3 mH to 10 H at 1 kHz 


Precision capacitors;
Capacitance;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
0.5fF for 1 pF at 1 kHz
5 fF for 10 pF, at 1 kHz
50 fF for 100 pF at 1 kHz
4.5 fF for 1 pF at 1 MHz
8 fF for 10 pF at 1 MHz
80 fF for 100 pF at 1 MHz
0.6 pF for 1000 pF at 1 kHz
0.9 pF for 1000 pF at 1 MHz
5 pF for 0.01 μF at 120 Hz to 1 kHz
50 pF for 0.1 μF at 120 Hz to 1 kHz
7 pF for 0.01 μF at 10 kHz
17 pF for 0.01 μF at 100 kHz
0.1 nF for 0.1 μF at 10 kHz
0.3 nF for 0.1 μF at 100 kHz
0.7 nF for 1 μF at 120 Hz
0.5 nF for 1 μF at 1 kHz
0.9 nF for 1 μF at 10 kHz

DC and low frequency electrical metrology - High-voltage/high-current standards and equipment
High voltage test sets;
Current; Voltage;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Output high voltage for DC test sets
0.68% from 1 kV to 40 kV
Output high voltage for AC test sets at 50 Hz
1.0% up to 2 kV
 0.8% from 2 kV to 28 kV
Dimensional metrology - Engineering equipment and precision instruments
Height setting micrometers;
Length measurements;

for compliance with ISO 7863

Engineers' comparators;
Length measurements;

for compliance with AS 2372
vertical comparators (analogue type) 

Autocollimators;
Angle (arc);
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
1 second of arc

Coordinate length measuring machines; Electronic levels; Length measuring machines; Precision projection apparatus;
Length measurements;


Angle plates; Bevel protractors; Bore gauges; Depth and height micrometers; Dial gauges; Engineers' parallels; External micrometers; Feeler gauges; Internal micrometers; Micrometer heads; Precision spirit levels; Sine bars and sine tables; Squares; Straight edges; Surface plates; Vernier calipers; Vernier height and depth gauges;
Angle (arc); Flatness; Length measurements; Parallelism;


Test sieves;
Length measurements;

AS 1152 and BS 1140
Minimum aperture 75 μm 

Steel rulers and measuring tapes;
Length measurements;
Comparison with a reference standard;
For compliance with AS 1290.4, AS 1294 and BS 4372
CAPABILITY
with Calibration and Measurement Capability of -
Retractable steel pocket rules
0.04 mm
Tape measures
 0.33 mm up to 15 m
 0.65 mm above 15 m up to 30 m
 (0.32 + 0.018L) mm where L is in metres for lengths above 30 m up to 50 m
 (0.23 + 0.022L) mm where L is in metres for lengths above 50 m up to 100 m
Steel rulers up to 3 m
 0.04 mm up to 3 m
1 metre state secondary standard rigid rule
to Schedule 4 of National Measurement Regulations
0.006 mm
Dimensional metrology - Jigs, fixtures, cutting tools, machine tools, gears, splines and serrations
Components and QC standards; Crimp tools; Cutting tools; Jigs and fixtures;
Length measurements;
Direct measurement;
CAPABILITY
Including hand crimping tools up to 40 mm
with Calibration and Measurement Capability of -
2 μm up to 25 mm
5 μm above 25 mm to 500 mm
15 μm above 500 mm to 1000 mm
50 μm above 1000 mm to  2000 mm
Dimensional metrology - Length and angle standards
Area standards;
Length measurements;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
0.06 dm² from 10 dm² to 100 dm²

Gauge blocks and accessories;
Length measurements;

for compliance with AS 1457, grades 0, 1 and 2
up to 1 000 mm for compliance with AS 1457, grades 0, 1 and 2

Internal cylindrical standards;
Length measurements;

Setting rings for internal measuring instruments to AS 1001 and AS B294,
 grades A and B

Spherical standards;
Diameter;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
0.5 μm from 1 mm to 25 mm diameter

External cylindrical standards;
Length measurements;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
0.5 μm from 1 mm to 50 mm
0.8 μm above 50 mm to 100 mm
1 μm above 100 mm to 150 mm
1.3 μm above 150 mm to 200 mm
1.6 μm above 200 mm to 250 mm
2.0 μm above 250 mm to 300 mm
Dimensional metrology - Limit gauges and reference standards
Parallel screw plug gauges; Parallel screw ring gauges; Parallel thread gauges; Profile gauges; Taper screw plug gauges; Taper screw ring gauges;
Diameter; Length measurements;

Tolerance on profile gauges not less than ±5 μm

Plain gap gauges; Plain plug gauges; Plain ring gauges;
Diameter;
Direct measurement against a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Plain plug gauges
0.8 μm for sizes up to 50 mm
1.5 μm for sizes from 50 mm to 150 mm
3 μm for sizes from 150 mm to 300 mm
Plain ring & gap gauges
1.5 μm from 0.5 mm to 75 mm
3 μm above 75 mm to 150 mm
5 μm above 150 mm to 300 mm

Plain plug gauges;
Diameter;

up to 300 mm
CAPABILITY
0.8 μm up to 50 mm
1.5 μm above 50 mm to 150 mm
3 μm above 150 mm to 300 mm

Taper plug gauges;
Diameter; Taper;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Tapers up to 1 in 8
3 μm up to 50 mm
5 μm above 50 mm to 150 mm
Tapers from 1 in 8 to 1 in 3
5 μm up to 50 mm
8 μm above 50 mm to 150 mm

Taper ring gauges;
Diameter; Taper;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Tapers up to 1 in 8
5 μm from 6 mm to 50 mm
8 μm above 50 mm to 150 mm
Tapers from 1 in 8 to 1 in 3
8 μm from 6 mm to 50 mm
10 μm from 50 mm to 150 mm

Screw pitch reference standards;
Major diameter and simple pitch diameter; Minor diameter and simple pitch diameter;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
1 μm up to 50 mm
Dimensional metrology - Surface topography
Surface finish reference standards;
Length measurements; Surface texture;
Direct measurement;
CAPABILITY
with Calibration and Measurement Capability of -
0.02 μm

Cylinders; Roundness standards; Surface finish reference standards;
Roundness; Surface texture;

Dimensional metrology - Survey and alignment equipment
Electronic distance measuring equipment;
Length measurements;
Direct measurement;
CAPABILITY
with Calibration and Measurement Capability of -
1 mm from 0.5 m to 30 m
Flow metrology - Flow measuring devices and systems
Liquid meters;
Volume (and nominal flow rate);
Gravimetric method; Volumetric transfer;
at flow rates from 100 mL/h up to 500 litres/minute
CAPABILITY
with Calibration and Measurement Capability of
0.04% from 100 ml/h to 500 l/min


Force metrology - Force measuring and testing equipment
Force gauges;
Force in compression;
Comparison measurement with reference load cell;
Axial type force gauges
CAPABILITY
with Calibration and Measurement Capability of -
0.03% up to 500 N 


Force in tension;
Comparison measurement with reference load cell;
Axial type force gauges
CAPABILITY
with Calibration and Measurement Capability of -
0.01% or 0.04 N (whichever is greater) up to 1 000 N 
High frequency electrical metrology - Communications, electromagnetic field strength and EMC test equipment
Amplifiers; Attenuators; Communications systems; Data transmission measuring equipment; Electrical noise and interference measuring equipment; Electromagnetic field hazard meters and warning indicators; Harmonic emission compliance test systems; Impedance and reflection measuring equipment; Line impedance stabilisation networks (LISN); Line transmission measuring equipment; Power measuring equipment; Radio transmission measuring equipment; Spectrum analysers; Waveguide and coaxial components;
Internal reference impedance resistance; Reflection coefficient;
Comparison with a reference standard; Direct measurement by electrical input;
CAPABILITY
Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -
From 20 Hz to 45 MHz
(± 0.005 to ± 0.007) lin and (± 2.1 to ± 180) deg from (0.001 to 0.01) lin
(± 0.006 to ± 0.008) lin and (± 2.8 to ± 3.8) deg from (0.01 to 0.1) lin
(± 0.006 to ± 0.019) lin and (± 1.1 to ± 3.8) deg from (0.1 to 1.0) lin
From 45 MHz to 18 GHz
(± 0.005 to ± 0.029) lin and (± 24.0 to ± 180) deg from (0.001 to 0.01) lin
(± 0.005 to ± 0.029) lin and (± 7.3 to ± 29) deg from (0.01 to 0.1) lin
(± 0.005 to ± 0.029) lin and (± 1.1 to ± 9.9) deg from (0.1 to 1.0) lin
From 18 GHz to 26.5 GHz
(± 0.011 to ± 0.028) lin and (± 12.4 to ± 180) deg from (0.001 to 0.01) lin
(± 0.011 to ± 0.028) lin and (± 14.0 to ± 15.5) deg from (0.01 to 0.1) lin
(± 0.011 to ± 0.028) lin and (± 8.4 to ± 11.0) deg(0.1 to 1.0) lin
From 26.5 GHz to 50 GHz
(± 0.016 to ± 0.035) lin and (± 54 to ± 180) deg from (0.001 to 0.01) lin
(± 0.016 to ± 0.035) lin and (± 17.8 to ± 180) deg from (0.01 to 0.1) lin
(± 0.016 to ± 0.035) lin and (± 9.7 to ± 12.3) deg from (0.1 to 1.0) lin


Attenuation; Insertion loss; Internal reference impedance resistance;
Comparison with a reference standard;
CAPABILITY
Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -
For attenuation above 40 dB using a network analyser, the
laboratory's capability is limited to step attenuators or similar devices,
such that individual elements can be selectively measured
Using measuring receiver systems
From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 dBm to -100 dBm
0.45 dB from -100 dBm to -110 dBm
0.50 dB from -110 dBm to -120 dBm
0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
0.18 dB at +20 dBm to -10 dBm
0.19 dB from -10 dBm to -20 dBm
0.21 dB from -20 dBm to -30 dBm
0.23 dB from -30 dBm to -40 dBm
0.25 dB from -40 dBm to -50 dBm
0.27 dB from -50 dBm to -60 dBm
0.29 dB from -60 dBm to -70 dBm
0.33 dB from -70 dBm to -80 dBm
0.36 dB from -80 dBm to -90 dBm
0.44 dB from -90 dBm to -100 dBm
0.47 dB from -100 dBm to -110 dBm
0.51 dB from -110 dBm to -120 dBm
0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
0.67 dB at -10 dBm to -60 dBm
0.83 dB from -60 dBm to -90 dBm
Using VNA systems
From 5 Hz to 45 MHz
0.14 dB from 0 dB to 10 dB
0.14 dB from 10 dB to 30 dB
0.14 dB from 30 dB to 40 dB
0.14 dB from 40 dB to 70 dB
0.14 dB from 70 dB to 90 dB
0.14 dB from 90 dB to 100 dB
0.14 dB from 100 dB to 120 dB
From 45 MHz to 2 GHz
0.04 dB from 0 dB to 10 dB
0.09 dB from 10 dB to 30 dB
0.24 dB from 30 dB to 40 dB
0.33 dB from 40 dB to 70 dB
0.40 dB from 70 dB to 90 dB
0.43 dB from 90 dB to 100 dB
0.63 dB from 100 dB to 120 dB
From 2 GHz to 18 GHz
0.08 dB from 0 dB to 10 dB
0.08 dB from 10 dB to 30 dB
0.10 dB from 30 dB to 40 dB
0.18 dB from 40 dB to 70 dB
0.26 dB from 70 dB to 90 dB
0.26 dB from 90 dB to 100 dB
0.35 dB from 100 dB to 120 dB
From 18 GHz to 26.5 GHz
0.17 dB from 0 dB to 10 dB
0.18 dB from 10 dB to 30 dB
0.24 dB from 30 dB to 40 dB
0.59 dB from 40 dB to 70 dB
0.76 dB from 70 dB to 90 dB
0.78 dB from 90 dB to 100 dB
1.0 dB from 100 dB to 120 dB
From 26.5 GHz to 40 GHz
0.17 dB from 0 dB to 10 dB
0.25 dB from 10 dB to 30 dB
0.48 dB from 30 dB to 40 dB
0.91 dB from 40 dB to 70 dB
1.09 dB from 70 dB to 90 dB
1.2 dB from 90 dB to 100 dB
1.6 dB from 100 dB to 120 dB
From 40 GHz to 50 GHz
0.29 dB from 0 dB to 10 dB
0.66 dB from 10 dB to 30 dB
1.8 dB from 30 dB to 40 dB
2.8 dB from 40 dB to 70 dB
3.2 dB from 70 dB to 90 dB
3.5 dB from 90 dB to 100 dB
5.0 dB from 100 dB to 120 dB

Communications systems; Data transmission measuring equipment; Electrical noise and interference measuring equipment; Line transmission measuring equipment; Power measuring equipment; Radio transmission measuring equipment; Spectrum analysers;
Frequency;
Comparison with a reference standard; Comparison with a reference standard by differential measurement; Comparison with a reference standard by substitution measurement; Direct measurement by electrical input;
CAPABILITY
Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of -
Frequency characteristics
5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz
Frequency standards
5 parts in 1012 from 1 mHz to 10 MHz in main laboratory
7 parts in 1011 from 1 mHz to 10 MHz in VOSCAL laboratory


Power measuring equipment;
Power;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
including calibrations at VOSCAL mobile facility
from +20 dBm to -30 dBm at the reference power level appropriate to the sensor
absolute power calibration factor 
0.37 % at 1 mW and 50 MHz
1.3 % from 9 kHz to 18 GHz
2.0 % from 18 GHz to 26.5 GHz
2.3 % from 26.5 GHz to 40 GHz
3.7 % from 40 GHz to 50 GHz

Data transmission measuring equipment;
Voltage deviation;
Comparison with a reference standard by differential measurement;
CAPABILITY
Including calibrations performed in dedicated mobile laboratory (VOSCAL)
with Calibration and Measurement Capability of --
0.13 % from 1 mV to 4 V
Mass - Determination of mass and calibration of weighing devices
Mass standards;
Mass;
Gravimetric measurement against reference mass;
CAPABILITY
with Calibration and Measurement Capability of -
6 μg from 1 mg to 1 g
8 μg at 2 g
20 μg at 5 g
30 μg at 10 g
40 μg at 20 g
0.1 mg at 50 g
0.2 mg at 100 g
0.3 mg at 200 g
0.5 mg at 500 g
1.0 mg at 1 kg
4 mg at 2 kg
7 mg at 5 kg
10 mg at 10 kg
20 mg at 20 kg
500 mg at 25 kg
3 g from 50 kg to 100 kg
7 g at 250 kg
22 g at 500 kg
50 g at 1 000 kg
5 in 104 up to 25 t
Mass - Determination of mass and calibration of weighing devices
Industrial weighing devices; Precision laboratory balances;
Mass;
Gravimetric measurement against reference mass;
including on site calibrations



CAPABILITY
Including on-site calibrations
with Calibration and Measurement Capability of -
Precision laboratory balances 
1.3 in 106 or 32 μg (whichever is greater) up to 32 kg
Industrial balances 
1 in 105 up to 1500 kg
Pressure metrology - Pressure and vacuum measuring equipment
Barometers; Digital pressure gauges; Manometers; Mechanical pressure gauges; Pressure control devices; Pressure recorders; Pressure transducers; Vacuum gauges;
Absolute pressure;
By pressure calibrator; Comparison with dead weight tester; Comparison with reference instrument;
Pressure and vacuum gauges including test gauges AS 1349 and MSA Test Method 2
Pressure transducers and recorders MSA Test Method 1
Self indicating and electrical transducers with dc voltage or dc current output
Temperature range for on-site calibrations 15 °C to 25 °C
including on-site calibrations



CAPABILITY
including on-site calibrations
with Calibration and Measurement Capability of -
30 Pa from 5 kPa to 50 kPa,
8 Pa from 50 kPa to 110 kPa,
0.01% from 110 kPa to 110 MPa
Onsite Calibration
33 Pa from 5 kPa to 50 kPa
8 Pa from 50 kPa to 110 kPa
0.01% from 110 kPa to 16 MPa

Pressure metrology - Pressure and vacuum measuring equipment
Digital pressure gauges; Manometers; Mechanical pressure gauges; Pressure control devices; Pressure gauges; Pressure recorders; Pressure transducers;
Gauge pressure;
By pressure calibrator; Comparison with dead weight tester;
Pressure and Vacuum gauges Including test gauges AS 1349 and MSA Test Method 2
Pressure transducers and recorders MSA Test Method 1
Self indicating and electrical transducers with dc voltage or dc current output
Temperature range for on-site calibrations 15 °C to 25 °C
including on-site calibrations



CAPABILITY
Including on-site calibrations
with Calibration and Measurement Capability of -
0.006% or 2Pa (whichever is the greater) from -100 kPa to -1 kPa
2.4 Pa from -1 kPa to 1 kPa
0.006% or 2 Pa (whichever is the greater) from 1 kPa to 100 kPa
0.005% from 100 kPa to 700 kPa
0.009% from 700 kPa to 110000 kPa
0.012% from 110 MPa to 500 MPa

On-site calibration
30 Pa from -100 kPa to - 1 kPa
2.4 Pa from -1 kPa  to 1 kPa
0.1% or 33 Pa (whichever is greater) from 1 kPa to 16000 kPa
59 kPa  from 16000 kPa to 100000 kPa





Pressure metrology - Pressure standards
Pressure calibrators - Non-dead weight;
Gauge pressure;
Comparison with dead weight tester;
CAPABILITY
with Calibration and Measurement Capability of -
0.006% or 2 Pa(whichever is the greater) from -100 kPa to -1 kPa
2.4 Pa from -1 kPa to 1 kPa
0.006% or 2 Pa(whichever is the greater) from 1 kPa to 100 kPa
0.005% from 100 kPa to 700 kPa
0.009% from 700 kPa to 110000 kPa
0.012% from 110 MPa to 500 MPa
Temperature metrology - Ancillary temperature measuring equipment
Portable potentiometers; Process calibrators; Resistance bridges;
Resistance to temperature conversion;
Direct measurement by electrical input;


CAPABILITY
with Calibration and Measurement Capability of -
Portable potentiometers and temperature/instrument process calibrators
0.02% of reading + 3 μV
Resistance bridges
0.01% from 1 mΩ to 100 mΩ
0.02% above 100 mΩ to 1 Ω
0.005% above 1 Ω to 10 kΩ
0.02% above 10 kΩ to 1 MΩ
0.05% above 1 MΩ to 10 MΩ
0.1% above 10 MΩ to 100 MΩ
0.7% above 100 MΩ to 1 GΩ

Type R extension wire; Type S extension wire;
Volt to temperature conversion;
Direct measurement by electrical input;
Extension wires for rare metal and base metal thermocouples 
CAPABILITY
with aCalibration and Measurement Capability  of -
0.5 μV from 0°C to 40ºC

Digital voltmeters (DVM) and digital multimeters (DMM); Multi-channel thermocouple data recorders;
Volt to temperature conversion;
Direct measurement by electrical input;
CAPABILITY
with Calibration and Measurement Capability of -
Digital voltmeters
50 μV/V + 1 μV up to 1 V
10 μV/V + 1 μV from 1 V to 1 000 V
Indicators, recorders and controllers
0.1% of full scale reading
Temperature metrology - Humidity measuring equipment
Relative humidity sensors;
Temperature;
To be determined;
CAPABILITY
with Calibration and Measurement Capability of -
1.0ºC from -10°C to 15ºC
0.2ºC above 15°C to 45ºC
0.5ºC above 45°C to 65ºC


Relative humidity (RH);
Comparison with a reference standard; To be determined;
CAPABILITY
with Calibration and Measurement Capability of -
2% RH from 20°C to 24°C and in the range from 11% RH to 97% RH
Temperature metrology - Non-contact temperature measuring equipment
Radiation pyrometers; Thermal imaging systems;
Temperature;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Radiation Pyrometers
with an emissivity of 0.95 or 1.00
0.8 °C from -40 °C to 0 °C
1.0 °C above 0° C to 280 °C
1.8 °C above 280° C to 500 °C
3.0 °C above 500 °C to 800 °C
Thermal Imagers
with an emissivity of 0.95 or 1.00
1.9 °C from -15°C to 0°C
1.5 °C above 0°C to 60°C
8.0 °C above 60°C to 260°C




Temperature metrology - Temperature measuring equipment
Base metal thermocouples; Bimetallic systems; Digital temperature measuring systems; Filled metal systems; Liquid in glass (LIG) thermometers; Rare metal thermocouples; Surface probes; Vapour pressure thermometers;
Temperature;
Measurement against reference standard;
including on site calibrations



CAPABILITY
with Calibration and Measurement Capability of -
Rare metal thermocouples (with probe only and with thermometer as a system)
(5 + 0.002E) μV from 0°C to 1550°C
Base metal thermocouples (with probe only  and with thermometer as a system) including on site calibrations
0.1°C from -55°C to 180°C
1.0°C above 180°C to 500°C
2°C above 500°C to 950°C
3°C above 950°C to 1250°C
Surface probes (with probe only  and with thermometer as a system) 
0.7°C from 0°C to 20°C
1.2°C above 20°C to 300°C
2.2°C above 300°C to 500°C
Liquid-in-glass thermometers and digital temperature indicator systems
0.1°C from -55°C to 0°C
0.01°C at 0°C
0.05°C above 0°C to 180°C
0.2°C above 180°C to 300°C
Vapour pressure thermometers, Filled metal and Bimetallic systems 
0.2°C from -55°C to 20°C
1°C above 20°C to 180°C
2°C above 180°C to 650°C

Metallic resistance thermometers;
Resistance over oC range;
Direct temperature and electrical measurement against reference standard;
CAPABILITY
with Calibration and Measurement Capability  of -
Both RTDS on their own and with a Thermometer as a system
0.05°C from -55°C to 300°C
0.3°C above 300°C to 350°C
0.4 °C from 350 °C to 660 °C


Temperature metrology - Temperature standards and reference equipment
Rare metal thermocouples;
mV per oC;
To be determined;
0°C to 1550°C
CAPABILITY
with Calibration and Measurement Capability of -
Both B, R and S Thermocouples on their own  and with a Thermometer as a system
(5 + 0.002E) μV  

Dry block calibrators; Reference baths;
Temperature;
Direct measurement using a reference standard;
AS 2853
CAPABILITY
Controlled thermal calibration wells
with Calibration and Measurement Capability of -
0.2ºC from -55°C to 180ºC
0.5ºC above 180°C to 350ºC
1ºC above 350°C to 660ºC
2ºC above 660°C to 950ºC
4ºC above 950°C to 1250ºC
Temperature metrology - Verification of controlled enclosures
Environmental chambers - Humidity;
Humidity;
By temperature and humidity measurement;
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
3% RH from 20% RH to 90% RH and 15ºC to 35ºC
Temperature metrology - Verification of controlled enclosures
Autoclaves and sterilising ovens; Baths; Environmental chambers - Temperature; Freezers; Furnaces; Incubators; Ovens;
Temperature;
By methods of SAE AMS 2750; Direct temperature measurement;
AS 2853, BAC 5621 clauses 3.4 - 3.5 and AMS 2750D clauses 10.2 - 10.3
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
Ovens and Furnaces, Environmental Chambers (Temperature)
0.2°C from 0°C to 180°C
1°C above 180°C to 500°C
2°C above 500°C to 950°C
4°C above 950°C to 1550°C
Industrial freezers, Environmental Chambers (Temperature)
0.2°C from -55°C to 0°C
Time and frequency metrology - Frequency and time standards
Signal sources;
Frequency; Modulation; Sweep;
Direct measurement;
CAPABILITY
including calibrations at VOSCAL mobile facility
with Calibration and Measurement Capability of -
Frequency characteristics
5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz
Output characteristics
From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
0.13 dB at +20 dBm to -10 dBm
0.15 dB from -10 dBm to -20 dBm
0.16 dB from -20 dBm to -30 dBm
0.19 dB from -30 dBm to -40 dBm
0.21 dB from -40 dBm to -50 dBm
0.24 dB from -50 dBm to -60 dBm
0.26 dB from -60 dBm to -70 dBm
0.31 dB from -70 dBm to -80 dBm
0.34 dB from -80 dBm to -90 dBm
0.42 dB from -90 dBm to -100 dBm
0.45 dB from -100 dBm to -110 dBm
0.50 dB from -110 dBm to -120 dBm
0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
0.18 dB at +20 dBm to -10 dBm
0.19 dB from -10 dBm to -20 dBm
0.21 dB from -20 dBm to -30 dBm
0.23 dB from -30 dBm to -40 dBm
0.25 dB from -40 dBm to -50 dBm
0.27 dB from -50 dBm to -60 dBm
0.29 dB from -60 dBm to -70 dBm
0.33 dB from -70 dBm to -80 dBm
0.36 dB from -80 dBm to -90 dBm
0.44 dB from -90 dBm to -100 dBm
0.47 dB from -100 dBm to -110 dBm
0.51 dB from -110 dBm to -120 dBm
0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
0.67 dB at -10 dBm to -60 dBm
0.83 dB from -60 dBm to -90 dBm
Modulation characteristics
AM Depth
Carrier 0.15 kHz to 26.5 GHz
10% to 90% Modulation
0.93% from 20 Hz to 400 Hz
0.49% from 400 Hz to 10 kHz
1.71% from 10 kHz to 100k Hz
FM Deviation
0.15 MHz to 26.5 GHz
1.2% Peak deviation 1 to 320 kHz,
Modulation frequencies 10 Hz to 100 kHz
1.2% from 150 kHz to 26.5 GHz
Sweep characteristics
5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz
Output characteristics
From 5 Hz to 1 MHz
0.015 dB at +20 dBm to -40 dBm
0.021 dB from -40 dBm to -80 dBm
0.025 dB from -80 dBm to -110 dBm
From 1 MHz to 2.5 MHz
0.03 dB at +20 dBm to -40 dBm
0.06 dB from -40 dBm to -90 dBm
0.12 dB from -90 dBm to -110 dBm
From 2.5 MHz to 1.3 GHz
0.09 dB at +20 dBm to -10 dBm
0.11 dB from -10 dBm to -20 dBm
0.13 dB from -20 dBm to -30 dBm
0.16 dB from -30 dBm to -40 dBm
0.19 dB from -40 dBm to -50 dBm
0.22 dB from -50 dBm to -60 dBm
0.25 dB from -60 dBm to -70 dBm
0.29 dB from -70 dBm to -80 dBm
0.32 dB from -80 dBm to -90 dBm
0.35 dB from -90 dBm to -100 dBm
0.38 dB from -100 dBm to -110 dBm
0.44 dB from -110 dBm to -120 dBm
0.54 dB from -120 dBm to -127 dBm
From 1.3 GHz to 18 GHz
 0.13 dB at +20 dBm to -10 dBm
 0.15 dB from -10 dBm to -20 dBm
 0.16 dB from -20 dBm to -30 dBm
 0.19 dB from -30 dBm to -40 dBm
 0.21 dB from -40 dBm to -50 dBm
 0.24 dB from -50 dBm to -60 dBm
 0.26 dB from -60 dBm to -70 dBm
 0.31 dB from -70 dBm to -80 dBm
 0.34 dB from -80 dBm to -90 dBm
 0.42 dB from -90 dBm to -100 dBm
 0.45 dB from -100 dBm to -110 dBm
 0.50 dB from -110 dBm to -120 dBm
 0.55 dB from -120 dBm to -127 dBm
From 18 GHz to 26.5 GHz
 0.18 dB at +20 dBm to -10 dBm
 0.19 dB from -10 dBm to -20 dBm
 0.21 dB from -20 dBm to -30 dBm
 0.23 dB from -30 dBm to -40 dBm
 0.25 dB from -40 dBm to -50 dBm
 0.27 dB from -50 dBm to -60 dBm
 0.29 dB from -60 dBm to -70 dBm
 0.33 dB from -70 dBm to -80 dBm
 0.36 dB from -80 dBm to -90 dBm
 0.44 dB from -90 dBm to -100 dBm
 0.47 dB from -100 dBm to -110 dBm
 0.51 dB from -110 dBm to -120 dBm
 0.56 dB from -120 dBm to -127 dBm
From 26.5 GHz to 40 GHz
 0.40 dB at -10 dBm to -90 dBm
From 40 GHz to 50 GHz
 0.67 dB at -10 dBm to -60 dBm
 0.83 dB from -60 dBm to -90 dBm


Time and frequency metrology - Frequency, time and waveform measuring equipment
Clocks and timers; Time interval meters;
Time interval;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Time interval meters
1 in 109 + 100 ns from 1 μs to 1 000 s
Clocks and watches
0.04 s from 1 min to 24 h
RCD testers, trip time
0.40 ms up to 500 ms
0.75 ms from 500 ms to 2 s

Frequency analysers; Waveform measuring instruments;
Distortion; Frequency; Time interval; Voltage;
Comparison with a reference standard;
CAPABILITY
including calibrations at VOSCAL mobile facility
with Calibration and Measurement Capability of -
Frequency characteristics
5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz
Input characteristics
From 10 μV to 2.2 mV
3.0 mV/V at 10 Hz to 100 kHz
6.1 mV/V from 100 kHz to 300 kHz
12 mV/V from 300 kHz to 500 kHz
13 mV/V from 500 kHz to 1 MHz
From 2.2 mV to 22 mV
500 μV/V at 10 Hz to 50 kHz
800 μV/V from 50 kHz to 100 kHz
1.6 mV/V from 100 kHz to 300 kHz
2.4 mV/V from 300 kHz to 500 kHz
3.7 mV/V from 500 kHz to 1 MHz
From 22 mV to 0.22 V
300 μV/V at 10 Hz to 50 kHz
600 μV/V from 50 kHz to 100 kHz
1 mV/V from 100 kHz to 300 kHz
1.5 mV/V from 300 kHz to 500 kHz
2.9 mV/V from 500 kHz to 1 MHz
From 0.22 V to 2.2 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
500 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.9 mV/V from 500 kHz to 1 MHz
From 2.2 V to 22 V
300 μV/V at 10 Hz to 50 kHz
100 μV/from 50 kHz to 100 kHz
300 μV/V from 100 kHz to 300 kHz
1.1 mV/V from 300 kHz to 500 kHz
1.7 mV/V from 500 kHz to 1 MHz
From 22 V to 220 V
300 μV/V at 10 Hz to 50 kHz
200 μV/V from 50 kHz to 100 kHz
900 μV/V from 100 kHz to 300 kHz
4.4 mV/V from 300 kHz to 500 kHz
8.0 mV/V from 500 kHz to 1 MHz
From 220 V to 750 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 50 kHz
2.3 mV/V from 50 kHz to 100 kHz
From 750 V to 1000 V
100 μV/V at 40 Hz to 1 kHz
200 μV/V from 1 kHz to 20 kHz
600 μV/V from 20 kHz to 30 kHz
Tming characteristics
1 ns or 5 parts in 1012, which ever is the greater, from 10 ns to 105 seconds
Distortion
0.007% absolute at < 0.05% at 20 Hz to 20 kHz
13.5% of reading at > 0.05% to < 10% at 20 Hz to 20 kHz
0.027% absolute at < 0.1% at 20 kHz to 50 kHz
26.8% of reading at > 0.1% to < 10% at 20 Hz to 20 kHz
0.05% absolute at < 0.18% at 50 kHz to 100 kHz
26.8% of reading at > 0.18% to < 10% at 50 Hz to 100 kHz
.

Counters; Frequency meters; Time interval meters;
Frequency; Time interval;
Comparison with a reference standard;
CAPABILITY
including calibrations at VOSCAL mobile facility
with Calibration and Measurement Capability of -
Counters
5 parts in 1012 from 1 mHz to 12.4 GHz
2 parts in 1010 from 12.4 GHz to 46 GHz
8 parts in 108 from 46 GHz to 50 GHz
Time interval meters 1 ns or 5 parts in 1012, which ever is the greater, from 10 ns to 105 seconds.
Frequency standards 5 parts in 1012 

Stroboscopes; Tachometers;
Rotational speed;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Stroboscopes
 0.12 rpm from 6 rpm to 99 rpm
 1.2 rpm from 100 rpm to 999 rpm
 3.0 rpm from 1 000 rpm to 30 000 rpm
Tachometers
 0.02 rpm from 6 rpm to 99 rpm
 0.2 rpm from 100 rpm to 999 rpm
 2 rpm from 1 000 rpm to 99 000 rpm
Torque - Torque measuring and testing equipment
Torque transducers; Torque wrenches;
Torque;
Comparison with a reference standard;
AS 4115 and ISO 6789
Torque wrenches from 0.5 N.m to 1300 N.m clockwise and anti-clockwise
Torque transducers including torque calibrating devices from 0.5 N.m to 1000 N.m
CAPABILITY
with Calibration and Measurement Capability of -
Torque wrenches
 0.9%
Torque transducers including torque calibrating devices
0.012% 0.5 N.m to 115 N.m
0.03% from 115 N.m to 1 000 N.m
Volume and density - Determination of density
Density of liquids;
kg/m3;
Gravimetric method;
CAPABILITY
with Calibration and Measurement Capability of -
0.06 kg/mfrom 995 kg/m3 to 1000 kg/m3
Volume and density - Laboratory volumetric glassware and measures
Pipettes; Piston operated volumetric apparatus (POVA); Standard measures - < 50 L; Volumetric glassware and measures;
Volume;
Gravimetric method;
Pipettes, burettes, volumetric flasks and graduated cylinders for compliance with AS 2162.1 and ISO 8655
Calibration and verification of piston operated pipetters
by the methods of AS 2162.2 and ISO 8655
Pipettes, burettes, volumetric flasks and graduated cylinders at 200 μL, 2 mL, 20 mL, 200 mL, 500 mL
Industrial volumetric proving measures up to 10 000 L
Volume standards up to 500 L
Inspection standards up to 25 L
Piston Operated Volumetric Apparatus, pipettes (POVAS) at 10 μL and above 200 μL
CAPABILITY
with Calibration and Measurement Capability of -
Pipettes, burettes, volumetric flasks and graduated cylinders 
0.3 μL at 200 μL
1.1 μL at 2 mL
6 μL at 20 mL
22 μL at 200 mL
97 μL at 500 mL
Industrial volumetric proving measures
using volumetric methods 0.02%
using gravimetric methods 0.008%
Volume standard
 0.01%
Inspection standards
0.02%
Piston Operated Volumetric Apparatus, pipettes (POVAS)
0.04 μL at 10 μL
22 μL at 200 mL
97 μL at 500 mL