ISO/IEC 17025 (2017)
Calibration
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
Acoustical metrology - Acoustic equipment
Band pass filters;
Attenuation; Frequency response;
By methods of AS/NZS 4476; By methods of IEC 1260;
AS/NZS 4476 ;
IEC 61260 Clauses 4.4, 4.6, 4.8, 4.9, 4.10, 5.3, 5.5, 5.7, 5.8 and 5.9
CAPABILITY
with Calibration and Measurement Capability of -
0.15 dB in the frequency range 20 Hz to 20000 Hz

Sound level meters;
Electrical response; Sound pressure level;
By methods of AS 1259.1; By methods of AS 1259.2; By methods of IEC 651; By methods of IEC 804; By methods of IEC 61672-3;
AS 1259.1 ;
AS 1259.2 ; 
IEC 60651 Clauses 8.9, 8.10, 10.1, 10.2.2, 10.2.3, 10.3.2, 10.3.3, 10.3.4, 10.4.2, 10.4.3, 10.4.4, 10.4.5 ;
IEC 60804 Clauses 4.2, 9.1, 9.2.1, 9.2.2, 9.3.1, 9.3.2, 9.3.3, 9.3.4, 9.3.5 ;

IEC 61672.3
DIN 46567-2005-03

CAPABILITY
with Calibration and Measurement Capability of -
0.2 dB from 63 Hz to 12500 Hz
Acoustical metrology - Acoustic standards and reference equipment
Acoustic calibrators - Multi frequency; Acoustic calibrators - Single frequency;
Distortion; Frequency; Short term fluctuations; Sound pressure level;
By methods of AS/IEC 60942;
AS IEC 60942
CAPABILITY
with Calibration and Measurement Capability of -
0.15 dB for Sound Pressure  Level at 94 dB and 114 dB at nominal frequencies of 250 Hz and 1000 Hz
0.15 Hz  at 250 Hz and 1000 Hz (Frequency)
0.15 dB at 0.0 dB (Short term fluctuation)
0.5 % at 1.2% for Total Harmonic Distortion and Noise

Flow metrology - Flow measuring devices and systems
Sonic nozzles;
Flow rate;
Volumetric transfer;
Gaseous flow in the flow rate range up to 500 m³/h
CAPABILITY
with Calibration and Measurement Capability of -
the greater of: 0.18% of flow rate or 2 mL/h, with a minimum test volume of 1 mL.

Coriolis meters; Gas meters; Orifice meters;
Volume (and nominal flow rate);
Volumetric transfer;
Gaseous flow in the flow rate range of 2 mL/h to 3000 m³/h
CAPABILITY
with Calibration and Measurement Capability of -
Gaseous flow in the flow rate range of 2 mL/h to 1000 m³/h
the greater of: 0.18% of flow rate or 2 mL/h, with a minimum test volume of 1 mL;
Gaseous flow In the flow rate range of 1000 m³/h to 2000 m³/h
0.21% of flow rate, with a minimum test volume of 10 L;
Gaseous flow in the flow rate range of 2000 m³/h to 3000 m³/h
0.26% of flow rate, with a minimum test volume of 10 L.

Gaseous volume proving systems; Oil and gas measurement systems;
Volume (and nominal flow rate);
Volumetric transfer;
2 L to 200 kL
CAPABILITY
with Calibration and Measurement Capability of -
0.1% of volume, with a minimum test volume of 2 L

Flow computers;
Volume (and nominal flow rate);

in-house procedures WI-IN-008 and WI-IN-010
CAPABILITY
with Calibration and Measurement Capability of -
0.12% of volume, with a minimum test volume of 2 L.
Pressure metrology - Pressure and vacuum measuring equipment
Barometers;
Absolute pressure;
Comparison with reference instrument;
80 kPa to 105 kPa
CAPABILITY
with Calibration and Measurement Capability of-
7 Pa from 80 kPa to 105 kPa

Digital pressure gauges; Manometers; Mechanical pressure gauges; Pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges;
Absolute pressure; Gauge pressure;
Comparison with reference instrument;
AS 1349;

0 to 14 MPa
CAPABILITY
with Calibration and Measurement Capability of -
Gauge pressure
0.01% or 1 Pa (whichever is greater) from -95 kPa to -1.7 kPa
0.5 Pa from -1.7 kPa to 1.7 kPa;
0.01% or 1 Pa (whichever is greater) from 1.7 kPa to 14 MPa
Absolute pressure
0.01% or 2 Pa (whichever is greater) from 5 kPa to 14 MPa

Speed and velocity - Speed measuring devices
Vehicle with digital display;
Speed;
Direct measurement against a reference standard;
Vipac Method LI8519
30 to 110 km/h
CAPABILITY
with Calibration and Measurement Capability of -
0.5 km/h at speeds of 30 to 45 km/h;
0.7 km/h at speeds of 45 to 65 km/h;
0.9 km/h at speeds of 65 to 80 km/h;
1.2 km/h at speeds of 80 to 110 km/h;
Speed and velocity - Verification of fixed speed detector installations
Inductive loop speed measurement systems; Piezoelectric speed measurement systems; Traffic signal phase systems;
Field measurement of capacitance;
Direct electrical measurement;
IEC 60359-2001:"Electrical and electronic measurement equipment - Expression of performance"
at 1 kHz in the range 0.5 nF to 1 μF
CAPABILITY
with Calibration and Measurement Capability of -
0.1 nF or 0.6% of reading, whichever is greater


Field measurement of DC resistance;
Direct electrical measurement;
IEC 60359-2001:"Electrical and electronic measurement equipment - Expression of performance"
0.1 to 200 Ω
CAPABILITY
with Calibration and Measurement Capability of -
0.05 Ω


Field measurement of inductance;
Direct electrical measurement;
IEC 60359-2001:"Electrical and electronic measurement equipment - Expression of performance"
1 kHz in the range 10 μH to 2 mH
CAPABILITY
with Calibration and Measurement Capability of -
0.5 μH or 1.5% of reading, whichever is greater


Field measurement of voltage;
Direct electrical measurement;
IEC 60359-2001:"Electrical and electronic measurement equipment - Expression of performance"
Voltage measuring equipment (picoscope)
stored waveforms in the range 10 mV to 20 V
CAPABILITY
with Calibration and Measurement Capability of -
5 mV or 5 % of reading, whichever is greater


Field measurement of insulation resistance;
Direct electrical measurement;
IEC 60359-2001:"Electrical and electronic measurement equipment - Expression of performance"
100 kΩ to 500 MΩ
CAPABILITY
with Calibration and Measurement Capability of -
7.6% of reading.


Field measurement of AC resistance;
Direct electrical measurement;
IEC 60359-2001:"Electrical and electronic measurement equipment - Expression of performance"
at 1 kHz in the range 0.1 Ω to 200 Ω
CAPABILITY
with Calibration and Measurement Capability of -
0.05 Ω or 8.3% of reading, whichever is greater
Temperature metrology - Temperature measuring equipment
Digital temperature measuring systems;
Temperature;
Measurement against reference standard;
CAPABILITY
Integral thermometers in Flow Computers
with Calibration and Measurement Capability of -
0.5°C  in the range 10°C to 30°C
Vibration metrology - Vibration equipment
Accelerometers; Geophones; Velocity transducers;
Acceleration sensitivity; Frequency;
Comparison measurement against reference transducer;
Piezo-electric accelerometers of mass less than 200 g in the frequency range 10 Hz to 10 kHz ;
Velocity Transducers in the frequency range 5 Hz to 1 kHz ;
Geophones in the frequency range 5 Hz to 200 Hz
CAPABILITY
with Calibration and Measurement Capability of -
Piezo-electric accelerometers of mass less than 200 g
2 % over the frequency range 10 Hz to 5 kHz
5% over the frequency range 5 kHz to 10 kHz
Velocity Transducers using back- to- back techniques
2% over the frequency range 10 Hz to 1 kHz
Velocity Transducers using flexure-table techniques
5% over the frequency range 5 Hz to 200 Hz
Geophones
5% over the frequency range 5 Hz to 200 Hz

Vibration analysers; Vibration measuring systems;
Acceleration sensitivity; Frequency;
Comparison measurement against reference transducer;
Vibration, excitation or simulated excitation
in the frequency range 10 Hz to 10 kHz
CAPABILITY
with Calibration and Measurement Capability of -
2% over the frequency range 10 Hz to 5 kHz ;
5% over the frequency range 5 kHz to 10 kHz