SERVICE | PRODUCT | DETERMINANT | TECHNIQUE | PROCEDURE | LIMITATION / RANGE |
Mechanical performance evaluation of components for building envelopes, framing and interior lining
| Door, window and skylight assemblies;
| Air infiltration; Deflection; Operating force; Proof load; Strength at ultimate limit state loading; Structural performance evaluation; Water penetration resistance;
| Cyclic pressure; Static pressure; | including on-site tests to AS/NZS 4420.1; AS 2047 Section 2 | |
|
| Facade assemblies including interior and exterior cladding systems;
| Air infiltration; Deflection; Proof load; Strength at ultimate limit state loading; Structural performance evaluation; Water penetration resistance;
| Cyclic pressure; Static pressure; | including on-site tests to AS/NZS 4284 Sections 8.2, 8.3, 8.4, 8.5, 8.6, 8.8 and Appendices C, D, E (CSIRO SIROWET procedure); NCC Building Code of Australia (Volume 1, Section FV1 and Volume 2, Section V2.2.1) | |
|
| Facade assemblies including interior and exterior cladding systems; Wall, floor and ceiling panels;
| Water penetration resistance;
| Field check - Spray; | including on-site tests to AAMA 501.2 | |
|
Products and appliances connected to the water supply - Physical evaluation
| Water service products - Connectors, filters, fittings, hoses and pipes;
| Back siphonage; Leakage; Pressure; Pressure cycling resistance; Pull-out resistance; Reversion; Thermal cycling; Thread form evaluation; Torque;
| Not applicable; | AS 1722.2, ISO 7.1 Field testing of thread checks in accordance with ISO7.1 and ISO 228.1 AS/NZS 1260 Sections 3, 4, 5 AS/NZS 1462 Parts 1, 6 AS/NZS 1477 Clauses 3.3.1, 3.3.2, 3.3.3, 3.3.6, 3.4.1, 3.4.2, 3.4.3, 3.4.4, 3.5.1, 3.5.2 AS/NZS 2492 Section 2.3, Table 2.1 AS/NZS 4130 Sections 10.1, 10.2, 10.4 including dimensional measurements for determination of compliance with Section 9.1 AS/NZS 4441 Sections 11.1
| Hydrostatic pressure tests in the range 0.25 to 20,000 kPa Water flow pressure tests in the range 1 to 2,000 kPa Water flow rates in the range 0 to 400 L/s Static torque tests in the range 0 to 646 Nm Vacuum pressure tests in the range 0 to -100 kPa Force measurement tests in the range 0 to 10,000 N Linear dimensions 0.02 mm to 8 m Water temperature -100°C to 80°C
|
|
|
| Endurance; Hydrostatic pressure;
| Not applicable; | AS/NZS 4130 Section 10.1 , 10.4 and AS/NZS 4129
| |
|
Thermal performance evaluation of building and insulating products
| Building envelopes;
| Air permeability;
| Fan pressurisation; | BS EN 13829, AS/NZS ISO 9972
| |
|