Back to Search Results


Address Details:
126 Oxford Street
COLLINGWOOD, VIC 3066
AUSTRALIA Map
www.auscal.com.au

Contact Details:
Mr Robert Thomson
+61(03) 94175688

Availability:
Services available to external clients

SCOPE OF ACCREDITATION   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.



ISO/IEC 17025 (2005)
Calibration
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
Mass - Determination of mass and calibration of weighing devices
Industrial weighing devices; Laboratory weighing devices; Precision laboratory balances;
Mass;
Gravimetric measurement against reference mass;
Up to 4000 kg
CAPABILITY
with Calibration and Measurement Capability of -
2 in 106 or 20 μg (whichever is greater) ) up to 200 g
1 in 105 or 1 mg (whichever is greater) above 200 g to 30 kg
5 in 105 or 100 mg (whichever is greater) above 30 kg to 4000 kg

ISO/IEC 17025 (2017)
Calibration
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
DC and low frequency electrical metrology - Electrical instrument calibrators
Instrument calibrators;
AC current; DC current; DC voltage; Resistance;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
AC Current
1% reading from 5 mA to 500 mA
3% reading above 500 mA to 1 A
Trip current for RCD/ELCD testers from 5 mA to 1 A

DC Current
0.0013 mA from 4 mA to 24 mA

DC Voltage
0.04% reading from 10 mV to 40 mV
0.01% reading above 40 mV to 50V

Resistance
0.1% reading from 5 Ω to 25 Ω
0.02% reading above 25 Ω to 500 kΩ
DC and low frequency electrical metrology - Electrical measurement and test equipment
Ammeters; Current clamps; Digital multimeters (DMM); Ohm meters; Voltmeters;
AC current; AC voltage; DC current; DC voltage; Resistance;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
AC Current
100 nA + 0.20% reading from 100 μA to 330 μA and 10 Hz to 1 kHz
 150 nA + 0.30% reading from 100 μA to 330 μA and 1 kHz to 5 kHz
 200 nA + 0.80% reading from 100 μA to 330 μA and 5 kHz to 10 kHz
 400 nA + 1.60% reading from100 μA to 330 μA and 10 kHz to 30 kHz
 200 nA + 0.20% reading from 330 μA to 3.3 mA and 10 Hz to 5 kHz
 600 nA + 1.00% reading from 330 μA to 3.3 mA and 5 kHz to 30 kHz
 2 μA + 0.18% reading from 3.3 mA to 33 mA and 10 Hz to 45 Hz
 2 μA + 0.04% reading from 3.3 mA to 33 mA and 45 Hz to 1 kHz
 2 μA + 0.08% reading from 3.3 mA to 33 mA and 1 kHz to 5 kHz
 200 μA + 0.40% reading from 3.3 mA to 33 mA and 5 kHz to 30 kHz
 20 μA + 0.18% reading from 33 mA to 330 mA and 10 Hz to 45 Hz
 20 μA + 0.04% reading from 33 mA to 330 mA and 45 Hz to 1 kHz
 100 μA + 0.20% reading from 33 mA to 330 mA and 1 kHz to 10 kHz
 200 μA + 0.40% reading from 33 mA to 330 mA and 10 kHz to 30 kHz
 100 μA + 0.183% reading from 330 mA to 3 A and 10 Hz to 45 Hz
 100 μA + 0.063% reading from 330 mA to 3 A and 45 Hz to 1 kHz
 1 mA + 0.063% reading from 330 mA to 3 A and 1 kHz to 5 kHz
 2 mA + 0.10% reading from 3 A to 11 A and 45 Hz to 1 kHz
 2 mA + 3.00% reading from 3 A to 11 A and 1 kHz to 5 kHz
 5 mA + 0.15% reading from 11 A to 20.5 A and 45 Hz to 1 kHz
 10 mA + 0.6% reading  from 3.2 to 10.5 A and 3 kHz to 10 kHz
 0.45% reading from 20 A to 1000 A and 10 Hz to 100 Hz for clamp-on meters
 using multiple turns

DC Current
0.05 μA + 0.02% reading from 1 μA to 3.3 mA
2.5 μA + 0.012% reading above 3.3 mA to 330 mA
40 μA + 0.04% reading above 330 mA to 3 A
500 μA + 0.05% reading above 3 A to 11 A
750 μA + 0.10% reading above 11 A to 20.5 A
0.4% reading from 20 A to 1000 A for clamp-on meters using multiple turns

AC Voltage
6 μV + 0.08% reading from 10 mV to 33 mV and 10 Hz to 45 Hz
6 μV + 0.02% reading from 10 mV to 33 mV and 45 Hz to 20 kHz
6 μV + 0.10% reading from 10 mV to 33 mV and 20 kHz to 50 kHz
8 μV + 0.03% reading from 33 mV to 330 mV and 10 Hz to 20 kHz
8 μV + 0.06% reading from 33 mV to 330 mV and 20 kHz to 50 kHz
32 μV + 0.09% reading from 33 mV to 330 mV and 50 kHz to 100 kHz
50 μV + 0.03% reading from 330 mV to 3.3 V and 10 Hz to 50 kHz
125 μV + 0.07% reading from 330 mV to 3.3 V and 50 kHz to 100 kHz
0.65 mV + 0.03% reading from 3.3 V to 33 V and 10 Hz to 45 Hz
0.6 mV + 0.015% reading from 3.3 V to 33 V and 45 Hz to 10 kHz
0.6 mV + 0.035% reading from 3.3 V to 33 V and 10 kHz to 50 kHz
1.6 mV + 0.09% reading from 3.3 V to 33 V and 50 kHz to 100 kHz
2 mV + 0.02% reading from 33 V to 330 V and 45 Hz to 1 kHz
6 mV + 0.03% reading from 33 V to 330 V and 1 kHz to 50 kHz
50 mV + 0.20% reading from 33 V to 330 V and 50 kHz to 100 kHz
10 mV + 0.03% reading from 330 V to 1020 V and 45 Hz to 10 kHz
DC Voltage
1 μV + 0.0024% reading from 10 mV to 330 mV
20 μV + 0.0020% reading above 300 mV to 33 V
150 μV + 0.0018% reading above 33 V to 330 V
1500 μV + 0.0018% reading above 330 V to 1020 V
Resistance
15 mΩ + 0.01% reading from 1 Ω to 33 Ω
20 mΩ + 0.003% reading above 33 Ω to 330 Ω
0.2 Ω + 0.003% reading above 330 Ω to 3.3 kΩ
1 Ω + 0.003% reading above 3.3 kΩ to 33 kΩ
10 Ω + 0.003% reading above 33 k Ω to 330 kΩ
150 Ω + 0.006% reading above 330 kΩ to 3.3 MΩ
2500 Ω + 0.03% reading above 3.3 MΩ to 33 MΩ
3000 Ω + 0.05% reading above 33 MΩ to 110 MΩ
0.6% reading for portable appliance testers down to 0.1 Ω

DC and low frequency electrical metrology - Electrical standards
Current shunts;
Current;
Comparison with a reference standard;
From 0.01 Ω to 100 Ω at maximum current of 10 A
CAPABILITY
with Calibration and Measurement Capability of -
0.7% reading

Conductance boxes; Precision resistors; Resistance boxes;
Resistance;
Comparison with a reference standard;
0.1 Ω  to 100 MΩ
CAPABILITY
with Calibration and Measurement Capability of -
0.12% reading from 0.1 Ω  to 100 Ω
0.012% reading above 100 Ω to 1 kΩ
0.05% reading above 1 kΩ to 10 MΩ
0.8% reading above 10 Ω to 100 MΩ
Dimensional metrology - Engineering equipment and precision instruments
Micrometer setting gauges;
Length measurements;
Comparison with a reference standard;
Up to 1200 mm
CAPABILITY
with Calibration and Measurement Capability of -
(1 + 0.007L) μm up to 1200 mm where L is the length in mm

Depth and height micrometers;
Length measurements;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
2 μm from 1 mm to 125 mm
(1.1+L/180) μm above 125 mm to 600 mm where L is the indicated depth in mm

Bore gauges;
Length measurements;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
2.5 μm from 2 mm to 50 mm
3.5 μm above 50 mm to 200 mm

Micrometer heads;
Length measurements;
Comparison with a reference standard;
Including compliance with AS 2328
CAPABILITY
with Calibration and Measurement Capability of -
(0.4+0.6R) μm where R is the resolution in μm

Dial gauges;
Length measurements;
Comparison with a reference standard;
Dial gauges and other displacement measuring devices


CAPABILITY
with Calibration and Measurement Capability of -
Dial Gauges
(0.8 + 0.032L) μm where L is the range in mm from 1 mm to 100 mm
Digital Indicators
(0.8 + 0.013L) μm where L is the range in mm from 1 mm to 100 mm
Dial Test Indicators

(0.8 + 100R) μm where R is the resolution in mm


Dial gauges; Thickness gauges;
Length measurements;
Comparison with a reference standard;
Including compliance with AS 2103
CAPABILITY
with Calibration and Measurement Capability of -
(0.8 + 0.032L) μm from 1 mm to 100 mm where L is the range in mm

External micrometers;
Length measurements;
Comparison with a reference standard;
Including compliance with AS 2102
CAPABILITY
with Calibration and Measurement Capability of -
1.8 μm up to 25 mm
2.6 μm above 25 mm to 100 mm
(1.8+0.01L) μm where L is the length in mm
above 100 mm to 1200 mm

Straight edges;
Length measurements;
Comparison with a reference standard;
Including compliance with AS 1003 and AS B72
CAPABILITY
with Calibration and Measurement Capability of -
2 μm from 50 mm to 300 mm
3 μm above 300 to 500 mm
5 μm above 500 to 1000 mm
8 μm above 1000 to 1500 mm

Extensometers;
Length measurements;
Comparison with a reference standard;
in laboratory and in situ
Including compliance to AS 1545
CAPABILITY
with Calibration and Measurement Capability of -
(0.89 + 0.79L) μm from 0.01 mm to 250 mm where L is the indicated extension in mm

Vernier calipers;
Length measurements;
Comparison with a reference standard;
Including compliance with AS 1984, BS 887 and JIS 7507
CAPABILITY
with Calibration and Measurement Capability of -
(10 + 0.025L) μm up to 1.5 m for indication errors where L is the scale value in mm

Vernier height and depth gauges;
Length measurements;
Comparison with a reference standard;
Including compliance with AS B138
CAPABILITY
with Calibration and Measurement Capability of -
Height gauges
 2.5 μm from 10 mm to 300 mm
 (6 + 0.006L) μm from 300 mm to 1000 mm where L is the indicated height in mm
 Depth gauges
 6 μm from 1 to 100 mm
 (5.5 + 0.006L) μm above 100 mm to 1000 mm where L is the indicated depth in mm

Precision spirit levels;
Angle (arc);
Comparison with a reference standard;
Including compliance with AS 2054
CAPABILITY
with Calibration and Measurement Capability of -
2 seconds of arc limited to  a sensitivity of 10 seconds of arc

Internal micrometers;
Length measurements;
Comparison with a reference standard;
Including compliance with AS 2101
CAPABILITY
with Calibration and Measurement Capability of -
2.5 μm from 25 mm to 150 mm
4 μm above 150 mm to 300 mm
(1.5 + 0.008L) μm above 300 mm to 900 mm
where L is the length in mm

Surface plates;
Flatness;
Comparison with a reference standard;
Including compliance with AS 1004
Excluding clause 3.4 rigidity
CAPABILITY
with Calibration and Measurement Capability of -
(3.6 L + 2) μm where L is length of longest side of the surface/table

Eccentric mandrels;
Length measurements;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
0.21 μm from 1 to 10 μm eccentricity
0.43 μm from 10 to 30 μm eccentricity

Bevel protractors;
Angle (arc);
Comparison with a reference standard;
Including compliance with AS B139
CAPABILITY
with Calibration and Measurement Capability of -
3.6 minutes of arc from 150 mm to 300 mm

Feeler gauges;
Length measurements;
Comparison with a reference standard;
Including compliance with 1655
CAPABILITY
with Calibration and Measurement Capability of -
(6L + 0.7) μm from 0.04 mm to 1 mm where L is thickness in mm

Steel rulers and measuring tapes;
Length measurements;
Comparison with a reference standard;
Including compliance to AS 1290.4 (only to retractable steel pocket rules)
CAPABILITY
with Calibration and Measurement Capability of -
Steel rules
5.4 μm or (3.5+0.007L) μm (whichever is greater) up to 2 m where L is the length in mm
Retractable steel pocket rules
0.47 mm from 0.5 mm to 10 m

Squares;
Length measurements;
Comparison with a reference standard;
Including compliance with BS 939
CAPABILITY
with Calibration and Measurement Capability of -
2 μm from 100 mm to 200 mm
2.6 μm above 200 mm to 450 mm
4.3 μm above 450 mm to 600 mm
Dimensional metrology - Jigs, fixtures, cutting tools, machine tools, gears, splines and serrations
Components and QC standards; Crimp tools; Cutting tools; Jigs and fixtures;
Length measurements;
Comparison with a reference standard by differential measurement;
CAPABILITY
with Calibration and Measurement Capability of -
(1 + 0.007 L) μm up to 1200 mm where L is the length in mm
Dimensional metrology - Length and angle standards
Precision graticules; Precision linear scales;
Length measurements; Microscope graticules;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Precision graticules
1.5 μm with a minimum scale separation of 0.01 mm
Precision linear scales
2 μm up to 500 mm 

Dial gauge calibrators; Extensometer calibrators;
Length measurements;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
(0.4+0.6R) μm where R is the resolution in μm
Dimensional metrology - Limit gauges and reference standards
Plain plug gauges; Plain ring gauges;
Diameter;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
Plain plug gauges
1 μm from 2 mm to 50 mm
3 μm above 50 mm to 250 mm
Plain ring gauges
1 μm from 2 mm to 50 mm
3 μm above 50 mm to 250 mm

Indicator gauges; Radius gauges;
Radius;
Comparison with a reference standard;
CAPABILITY
with Calibration and Measurement Capability of -
(8+1.1R) μm where R is the radius in mm
Force metrology - Force measuring and testing equipment
Aircraft weighing kits; Hydraulic rams and jacks; Load cells; Load measuring rings;
Force in compression; Force in tension;
Comparison measurement with reference load cell;
In tension up to 1000 kN and compression up to 500 kN to class AA including compliance to AS 2193
In tension up to 3.3 MN and in compression up to 20 MN to class A including compliance to  AS 2193
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.17% reading from 0.01 N to 500 kN in compression
0.17% reading from 0.01 N to 1000 kN in tension
0.25% reading above 500 kN to 20 MN in compression
0.25% reading above 1000 kN to 3.3 MN in tension
Force metrology - Force measuring and testing equipment
Tension and universal machines in tension;
Force in tension;
Comparison measurement with reference load cell;
Up to 500 kN to class AA and up to 3.3 MN to class A including compliance to AS 2193 and including testing to ISO 7500-1 and ASTM E4
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.17% reading from 0.01 N to 1000 kN
0.25% reading above 1000 kN to 3.3 MN
 
Force metrology - Force measuring and testing equipment
Elastic force measuring devices;
Force in compression; Force in tension;
Comparison measurement with reference load cell;
Calibration of devices such as load measuring rings for soil testing machines,
electronic load cells and hydrostatic weighing units including those in
batching plants and aircraft weighing kits
including compliance to class AA including compliance to AS 2193
including compliance to class A including compliance to AS 2193
0.01 N to 20 MN  in compression
0.01 N to 3.3 MN.  in tension
in tension up to 1000 kN and compression up to 500 kN to class AA including compliance to AS 2193

in tension up to 3.3 MN and in compression up to 20 MN to class A including compliance to AS 2193
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.17% reading from 0.01 N to 500 kN in compression
0.17% reading from 0.01 N to 1000 kN in tension
0.25% reading above 500 kN to 20 MN in compression
0.25% reading above 1000 kN to 3.3 MN in tension
Force metrology - Force measuring and testing equipment
Compression and universal machines in compression;
Force in compression;
Comparison measurement with reference load cell;
Up to 500 kN to class AA and up to 20 MN to class A of the requirements of AS 2193 and including testing to ISO 7500-1 and ASTM E4
Verification of compression testing machines for concrete including self-alignment and restraint on tilt tests for compliance with BS 1881 Part 115
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.17% reading from 0.01 N to 500 kN
0.25% reading above 500 kN to 20 MN

Paper product testing equipment;
Force in compression; Force in tension;
Comparison measurement with reference load cell;
Paper Burst (AS/NZS 1301.403s)
Densometer (AS 1301.420s)
Board Burst (AS/NZS 1301.438s)
Tensile/fracture toughness (AS 1301.448s)
Crush testing (AS/NZS 1301.449s)
STFI compression strength (AS 1301.450rp)
Box compression (AS 1301.800s)
 Huygen internal bond testers
 Taber stiffness (AS 1301.431rp)
Huygen internal bond testers
100 J/m2 to 350 J/m2
Taber stiffness
65 Taber units to 1000 Taber units
CAPABILITY
with Calibration and Measurement Capability of -
Huygen internal bond testers
1.4 J/m2 from 100 J/m2 to 350 J/m2
Taber stiffness
1.1% of range from 65 to 1000 Taber units
Force metrology - Force standards
Force calibrating equipment; Force standards and load cells used as force standards;
Force in compression; Force in tension;
Comparison measurement with reference load cell;
Including determination of class 0 requirements of AS 2193 and compliance with ISO 379 and ASTM E74
9.8 N to 10 kN
CAPABILITY
with Calibration and Measurement Capability of -
0.03% of reading or 0.14 N (whichever is greater)
Force metrology - Hardness standards and equipment
Brinell hardness machines; Portable Brinell measuring microscopes;
Brinell hardness;
Comparison with a reference standard;
including on site calibrations




Penetrometers and penetration cones;
Penetration resistance;
Direct length measurement;
AS 1289.6.3.2
Force metrology - Hardness standards and equipment
Izod impact machines;
Izod impact;
Comparison with a reference standard; Direct force and length measurement;
2 J to 170 J
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.2% reading from 2 J to 170 J

Rubber bases;
Rubber hardness;
Comparison with a reference standard;
25 IRHD to 97 IRHD
CAPABILITY
with Calibration and Measurement Capability of -
0.7 IRHD
Force metrology - Hardness standards and equipment
Rubber bases;
Rubber hardness;
Comparison with a reference standard;
including on site calibrations



Force metrology - Hardness standards and equipment
Charpy impact machines;
Charpy impact;
Comparison with a reference standard; Direct force and length measurement;
0.5 J to 600 J
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.2% reading from 0.5 J to 600 J
Force metrology - Hardness standards and equipment
Indenters; Rockwell hardness machines; Rockwell superficial hardness machines;
Rockwell hardness;
Comparison with a reference standard;
including on site calibrations



Force metrology - Hardness standards and equipment
Indenters; Vickers hardness machines; Vickers low-load hardness machines; Vickers micro-hardness machines;
Vickers hardness;
Comparison with a reference standard;
including on site calibrations



Force metrology - Hardness standards and equipment
Dead weight micro-hardness rubber testers; Dead weight rubber hardness testers; Rubber hardness meters (durometers);
Rubber hardness;
Comparison with a reference standard;
From 10 IRHD to 99.5 IRHD
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
1% of reading in IRHD from 10 IRHD to 99.5 IRHD

Hardness standards;
Brinell hardness; Rockwell hardness; Vickers hardness;
Comparison with a reference standard;
Hardness of metal products
Brinell hardness tests
Rockwell hardness tests
Vickers hardness tests 
Hardness of metal products
Brinell hardness tests in the range 9.8 to 29.4 kN

Rockwell hardness tests using A, B, C, E, F, G, H, K, N, T scales

Vickers hardness tests in the range 9.8 to 980 N
Mass - Determination of mass and calibration of weighing devices
Mass standards;
Mass;
Gravimetric measurement against reference mass;
From 10 mg to 30 kg
CAPABILITY
with Calibration and Measurement Capability of -
0.03 mg from 10 mg to 5 g
0.04 mg above 5 g to 10 g
0.05 mg above 10 g to 20 g
0.06 mg above 20 g to 50 g
0.15 mg above 50 g to 100 g
0.20 mg above 100 g to 200 g
3.5 mg above 200 g to 1 kg
4 mg above 1 kg to 2 kg
10 mg above 2 kg to 5 kg
25 mg above 5 kg to 10 kg
50 mg above 10 kg to 20 kg
130 mg above 20 kg to 30 kg
Mass - Determination of mass and calibration of weighing devices
Industrial weighing devices; Laboratory weighing devices; Precision laboratory balances;
Mass;
Gravimetric measurement against reference mass;
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
2 in 106 or 20 μg (whichever is greater) ) up to 200 g
1 in 105 or 1 mg (whichever is greater) above 200 g to 30 kg
5 in 105 or 100 mg (whichever is greater) above 30 kg to 4000 kg
Pressure metrology - Pressure and vacuum measuring equipment
Pressure control devices; Pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges;
Gauge pressure;
Comparison with dead weight tester; Comparison with reference instrument;
Including test gauges as defined in AS 1349
-100 kPa to 120 MPa
including on site calibrations



CAPABILITY
with Calibration and Measurement Capability of -
0.05% of reading or 0.05 kPa (whichever is greater) from 100 kPa to 120 MPa
0.23% of reading from - 100 kPa to - 20 kPa and 20 kPa to 100 kPa
0.46% of reading or 80 Pa (whichever is greater) from - 20 kPa to 20 kPa

For on site calibrations
with Calibration and Measurement Capability of -
0.23% of reading from -100 kPa to - 20 kPa and 20 kPa to 120 MPa
0.46% of reading or 80 Pa (whichever is greater) from - 20 kPa to 20 kPa
Temperature metrology - Ancillary temperature measuring equipment
Multi-channel thermocouple data recorders;
Resistance to temperature conversion; Volt to temperature conversion;
Direct measurement by electrical input;
-200°C to 1270°C for electrical simulation
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.1% of full scale reading from -200ºC to 1270ºC for electrical simulation
Temperature metrology - Humidity measuring equipment
Hygrometers; Relative humidity sensors;
Relative humidity (RH);
Comparison with a reference standard;
10% RH to 90% RH
CAPABILITY
with Calibration and Measurement Capability of -
1.7% RH from 10°C to 19°C and above 23°C to 60°C (in-situ)
1.5% RH above 19°C to 23°C (in-situ)
Temperature metrology - Non-contact temperature measuring equipment
Radiation pyrometers;
Temperature;
Comparison with a reference standard;
IR 7-14 μm pyrometers from 0°C to 450°C 
CAPABILITY
with Calibration and Measurement Capability of -
1.5°C + 0.8%T when designed for 0.95 emissivity
Temperature metrology - Temperature measuring equipment
Liquid in glass (LIG) thermometers;
Temperature;
Measurement against reference standard;
-30°C to 200°C
CAPABILITY
with Calibration and Measurement Capability of -
1/5 of one scale division or 0.05°C (whichever is the larger) at ice point
0.24°C from -30°C to 100°C
0.3°C above 100°C to 200°C

Base metal thermocouples;
Temperature;
Measurement against reference standard;
-80°C to 420°C
CAPABILITY
with Calibration and Measurement Capability of -
0.5°C + 0.1%T from -80°C to 0°C
0.5°C above 0°C to 420°C

Surface probes;
Temperature;
Measurement against reference standard;
25°C to 350°C
CAPABILITY
with Calibration and Measurement Capability of -
0.5°C + 0.4%T 

Bimetallic systems;
Temperature;
Measurement against reference standard;
0°C to 250°C
CAPABILITY
with Calibration and Measurement Capability of -
0.5°C
Temperature metrology - Temperature measuring equipment
Digital temperature measuring systems;
Temperature;
Measurement against reference standard;
- 80 °C to 1000°C (with sensor)
-200 °C to 1370 °C (electrical simulation)

including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.2°C from -80°C to 200°C
0.5°C above 200°C to 420°C
2°C above 420°C to 1000°C
0.5°C from 5°C to 80°C for thermohygrometers
0.3°C from -200°C to 1370°C by electrical simulation (CJC off)
0.7°C from -200°C to 1370°C by electrical simulation (CJC on)
Temperature metrology - Verification of controlled enclosures
Environmental chambers - Humidity;
Humidity;
By temperature and humidity measurement;
10% RH to 90% RH
CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
For range 10% RH to 90% RH
1.7% RH from 10°C to 19°C and above 23°C to 60°C
1.5% RH above 19°C to 23°C
Temperature metrology - Verification of controlled enclosures
Autoclaves and sterilising ovens; Environmental chambers - Temperature; Freezers; Furnaces; Incubators; Ovens;
Spatial uniformity; Temperature;
Direct temperature measurement;
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
Ovens and Furnaces
1.0°C from 0°C to 420°C
2°C from 420°C to 1100°C
.Incubators
0.5°C from ambient to 100°C
Autoclaves and sterilising ovens
1.0°C from ambient to 200°C
Industrial freezers
1.0°C from -80 to 0°C
Environmental Chambers (Temperature)
0.6ºC from -80 to 200ºC
Temperature metrology - Verification of controlled enclosures
Ovens;
Fluctuation;
Direct temperature measurement;
Efficiency of drying ovens including compliance to AS 1289.0 clause 4.2.3
Rate of loading of drying ovens including compliance to AS 1289.0 clause 4.2.4
including on site calibrations



CAPABILITY
Including on site calibrations
with Calibration and Measurement Capability of -
0.5 g/h
Time and frequency metrology - Frequency, time and waveform measuring equipment
Frequency meters;
Frequency;
Measurement against reference standard;
30 Hz to 2 MHz
CAPABILITY
with Calibration and Measurement Capability of -
5 μHz + 0.006% reading

Tachometers;
Rotational speed;
Comparison with a reference standard;
0.1 rpm to 100000 rpm
including mechanical attachment and strobe functionality tests
CAPABILITY
with Calibration and Measurement Capability of -
0.1 rpm from 100 to 1000 rpm
0.3 rpm above 1000 to 10000 rpm
3 rpm above 10000 to 100000 rpm

Time interval meters;
Time interval;
Measurement against reference standard;
10 ms to 1000 ms
including trip time for RCD/ELCB testers
CAPABILITY
with Calibration and Measurement Capability of -
1.2 ms
Torque - Torque measuring and testing equipment
Torque transducers; Torque wrenches;
Torque;
Comparison with a reference standard;
Including compliance to AS 4115
0.1 Nm to 1500 Nm
including on site calibrations



CAPABILITY
with Calibration and Measurement Capability of -
Torque wrenches (including on site calibrations)
0.5% of reading up to 1500 Nm
Torque transducers
0.04% of reading up to 100 Nm
0.1% of reading above 100 Nm to 1500 Nm