  • ISO/IEC 17025 (2005) - The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
    Calibration
  • SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
    Temperature metrology - Ancillary temperature measuring equipment
    Resistance bridges;
    Resistance to temperature conversion;
    Direct measurement by electrical input;
    from 0 Ω to 300 Ω
    CAPABILITY
    Calibration of AC bridges for temperature measurement
    with least uncertainties of measurement of -
    1 mΩ for linearity from 0 Ω to 300 Ω
    0.1 μΩ/Ω for linearity from 16 Ω to 130 Ω

    Type R extension wire; Type S extension wire;
    Volt to temperature conversion;
    Direct measurement by electrical input;
    from 0 °C to 50 °C
    CAPABILITY
    0.22 μV

    Digital voltmeters (DVM) and digital multimeters (DMM); Multi-channel thermocouple data recorders; Process calibrators;
    Volt to temperature conversion;
    Direct measurement by electrical input;
    0 °C to 1100 °C
    CAPABILITY
    Calibration of thermocouple indicators (sumilation only)
    with least uncertainties of measurement of -
    Type T
    0.09 °C from 0 °C to 500 °C
    Type K, J, and N
    0.09 °C from 0 °C to 1100 °C
    Type S and R
    0.12 °C from 0 °C to 1100 °C
    Temperature metrology - Humidity measuring equipment
    Dew point meters; Hygrometers; Psychrometers;
    Dew point; Temperature;
    To be determined;
    From -30 °C to 80 °C
    CAPABILITY
    Calibration of dew point meters
     with least uncertainties of measurement of -
     0.1 K for range of dew point from −30 °C to 80 °C
     Calibration of temperature sensors in dew point meters
     with least uncertainties of measurement of -
     from 0.28 K at −20 °C to 0.06 K at 14 °C in air
     0.06 K from 14 °C to 32 °C in air
     from 0.06 K at 32 °C to 0.37 K at 80 °C in air

    Relative humidity sensors;
    Relative humidity (RH); Temperature;
    To be determined;
    from 5% to 95% RH
    From 0 °C to 80 °C
    CAPABILITY
    Calibration of relative humidity sensors
     with least uncertainties of measurement of -

    Relative Humidity (RH)

    5%

    50%

    95%

    0 °C

    0.20

    0.87

    1.39

    23 °C

    0.19

    0.64

    1.10

    70 °C

    0.18

    0.50

    0.83

    80 °C

    0.18

    0.47

    0.79


     with a minimum frost point of −30 °C
     Calibration of temperature sensors for RH sensors and
     electronic psychrometers
     with least uncertainties of measurement of -
     from 0.28 K at −20 °C to 0.06 K at 14 °C in air
     0.06 K from 14 °C to 32 °C in air
     from 0.06 K at 32 °C to 0.37 K at 80 °C in air
    Temperature metrology - Non-contact temperature measuring equipment
    Thermal imaging systems;
    Temperature;
    To be determined;
    from -40 °C to 1100 °C
    CAPABILITY
    Calibration of thermal imaging cameras
     with least uncertainties of measurement of -
     from 0.1 °C at −40 °C to 0.5 °C at 250 °C
     from 0.5 °C at 250 °C to 2 °C at 1100 °C

    Clinical infrared thermometers; Radiation pyrometers;
    Temperature;
    To be determined;
    from -40 °C to 2900 °C
    CAPABILITY
    Radiation pyrometers
    from 0.1 °C at −40 °C to 0.3 °C at 250 °C
     from 0.5 °C at 250 °C to 2 °C at 1100 °C
     from 2 °C at 1100 °C to 4 °C at 2900 °C

     Calibration of ear thermometers
     in the range 25 °C to 45 °C
     with a least uncertainty of measurement of -
     0.1 °C
    Temperature metrology - Temperature measuring equipment
    Liquid in glass (LIG) thermometers;
    Temperature;
    Measurement against reference standard;
    from −200 °C to 300 °C
    CAPABILITY
    0.3 °C from −200 °C to −50 °C
    25 mK from −50 °C to −10 °C
    5 mK from −10 °C to 50 °C
    3 mK at 0 °C
    15 mK from 50 °C to 100 °C
    40 mK from 100 °C to 250 °C
    0.15 °C from 250 °C to 300 °C

    Base metal thermocouples; Surface probes;
    mV over oC range;
    Direct temperature and electrical measurement against reference standard;
    from −200 °C to 1100 °C
    CAPABILITY
    Calibration of Base Metal Thermocouples
    with least uncertainties of measurement of -
    Type T
    1.0 μV from −200 °C to 0 °C
    (1.0 + 0.01% E) μV from 0 °C to 200 °C
    Type K
    (1.0 + 0.036% E) μV from −200 °C to 200 °C
    (1.0 + 0.055% E) μV from 200 °C to 400 °C
    (4.14 + 0.06% E) μV from 400 °C to 1100 °C
    where E is the thermocouple voltage

    Calibration of surface temperature sensors
    with least uncertainties of measurement of -
    from 0.21 °C at 20 °C to 0.70 °C at 350 °C

    Digital temperature measuring systems;
    Temperature;
    Measurement against reference standard;
    from -200 °C to 1100 °C
    CAPABILITY
    Thermocouple Measuring Systems
    Type T
    1.0 μV from −200 °C to 0 °C
    (1.0 + 0.01% E) μV from 0 °C to 200 °C
    Type K
    (1.0 + 0.036% E) μV from −200 °C to 200 °C
    (1.0 + 0.055% E) μV from 200 °C to 400 °C
    (4.14 + 0.06% E) μV from 400 °C to 1100 °C
    where E is the thermocouple voltage

    Calibration of surface temperature measuring system
    with least uncertainties of measurement of -
    from 0.21 °C at 20 °C to 0.70 °C at 350 °C

    Metallic resistance Measuring Systems
    Calibration of standard PRTs using temperature fixed points
    with least uncertainties of measurement of -
    from 1 mK at −189.34 °C to 0.5 mK at −38.83 °C
    0.5 mK from −38.83 °C to 419.53 °C
    from 0.5 mK at 419.53 °C to 1.5 mK at 660.32 °C
    from 1.5 mK at 660.32 °C to 13 mK at 961.78 °C

    Calibration of standard PRTs and industrial PRTs by comparison
    against standard PRTs
    with least uncertainties of measurement of -
    5 mK at −200 °C
    5 mK at −80 °C
    3 mK at 0 °C
    3 mK at 250 °C
    6 mK at 550 °C
    13 mK at 960 °C
    Temperature metrology - Temperature standards and reference equipment
    Platinum-gold (Pt-Au) thermocouples; Rare metal thermocouples;
    mV per oC;
    To be determined;
    from 0 °C to 1560 °C
    CAPABILITY
    Calibration of Rare Metal Thermocouple
    with least uncertainties of measurement of -
    (0.31 + 0.011% E) μV from 0 °C to 1100 °C
     (0.31 + 0.014% E) μV from 0 °C to 1560 °C
     (0.008% E) μV at 200 °C for homogeneity
    where E is the thermocouple voltage

     Calibration of Pt-Au thermocouples
     with least uncertainties of measurement of -
     19 mK from 0 °C to 50 °C
     14 mK from 50 °C to 420 °C
     26 mK from 420 °C to 960 °C

    Platinum resistance thermometers (PRTs) reference standards;
    Temperature;
    To be determined;
    from −200 °C to 961.78 °C
    CAPABILITY
    Calibration of standard PRTs using temperature fixed points
     with least uncertainties of measurement of -
     from 1 mK at −189.34 °C to 0.5 mK at −38.83 °C
     0.5 mK from −38.83 °C to 419.53 °C
     from 0.5 mK at 419.53 °C to 1.5 mK at 660.32 °C
     from 1.5 mK at 660.32 °C to 13 mK at 961.78 °C

     Calibration of standard PRTs and industrial PRTs by comparison
     against standard PRTs

     with least uncertainties of measurement of -
     5 mK at −200 °C
     5 mK at −80 °C
     3 mK at 0 °C
     3 mK at 250 °C
     6 mK at 550 °C
     13 mK at 960 °C

    Black body sources;
    Temperature;
    To be determined;
    from −40 °C to 2000 °C
    CAPABILITY
    from 0.4 °C at −40 °C to 0.3 °C at 50 °C
    from 0.3 °C at 50 °C to 1.4 °C at 1000 °C
    from 1.4 °C at 1000 °C to 2.9 °C at 2000 °C

    Calibration of ear thermometer blackbodies
    in the range 25 °C to 45 °C
    with a least uncertainty of measurement of -
    0.025 °C

    Dry block calibrators;
    Temperature;
    To be determined;
    from −50 °C to 650 °C
    CAPABILITY
    from 0.15 °C at −50 °C to 0.05 °C at 50 °C
     from 0.05 °C at 50 °C to 0.15 °C at 650 °C

    Temperature reference standards - Fixed points;
    Silver (Ag) freezing point
    ; Aluminum (Al) freezing point; Argon (Ar) triple point; Cadmium freezing point; Gallium melting point; Indium (In) freezing point; Mercury (Hg) triple point; Tin (Sn) freezing point; Water triple point; Zinc freezing point;
    Direct measurement against a reference standard; Direct measurement against argon triple point; Direct measurement against H2O triple point; Direct measurement against mercury triple point;
    CAPABILITY
    1 mK at Ar triple point
     0.3 mK at Hg triple point
     0.1 mK at water triple point
     0.3 mK at Ga melting point
     0.5 mK at In freezing point
     0.3 mK at Sn freezing point
     0.4 mK at Cd freezing point
     0.5 mK at Zn freezing point
     1.5 mK at Al freezing point
     10 mK at Ag freezing point